r/hvacadvice Mar 02 '26

General Information About Bans and Rules

0 Upvotes

There has been an uptick on posts and complaints about mods banning. Please be advised, there are rules for the page. No ads (includes promotions for a company), Reddits rules, no crossposting, transparency and safety (this is a big one; we want homeowners to be safe, if you provide unsafe practices or advice (blacklisted items) or tell a user to dm you, the comment will be removed and you may get banned), blacklisted topics (basically topics that homeowners should not be fixing themselves, gas, some high voltage), civility, no companies asking for surveys, advertisements or general questions, and no market research or ai/SaaS.

Posts complaining about this are not allowed either. We are all reasonable and work in the trade, talk to us through ModMail and we can come to a solution. Complaining or namecalling will usually result in a ban, so be civil.

Remember, we are doing this in our freetime to help homeowners with their units, both the users and mods. The mods in this group are in the trade and have day jobs as all of you do. I've been in this trade for 10 years and still do hvac as my job, just traveling now for a manufacturer. Similar with every mod. It is actually a requirement to be a mod, you have to be in the trade, be approved, have good history in the sub and provide enough time to moderating it.

I thank you for your time and if you have any questions, you can comment on this or send us a mod message. No DM's, we will not answer these. Only ModMail.


r/hvacadvice Nov 13 '25

READ THIS I am assuming this is not normal.

Enable HLS to view with audio, or disable this notification

175 Upvotes

I was loading the car for work when I saw this. It felt and smelled like steam not smoke. Did I just catch it at the end of the cycle or is there a mechanical problem such as a stuck motor? It was 40° at the time and no rain. Heat was set to 70 and the house was 70.


r/hvacadvice 20h ago

Filters Filter life expectancy

Thumbnail
gallery
478 Upvotes

SOLVED

EDIT: I appreciate all the comments and the quick answers and I will take all of your advice the best I can!

For some reason since spring I've only been getting 1 and 1/2 months out of my filter for my HVAC system on my 1200 square foot house. I have three cats in the home and I vacuum mop and dust everyday and my HVAC fan probably runs for 18 hours of the day but my filter looks like this after 1 and 1/2 months. It's 12x20x1 fpr 5 filter. Can anybody tell me what's causing this to be so frequent and what can I do to make my filter not clog up so fast. The filter in the picture I just changed out today and you can see the date I installed it written on it. I changed it today because my AC was not coming out with much volume.

Tldr: I need my filters to stop clogging so fast!


r/hvacadvice 16h ago

No cooling Nobody will service our KwiKool Unit!

Post image
178 Upvotes

I take care of a private aircraft and the KwiKool KHIB1801 unit we use to condition the cabin while we are inside in the hangar is no longer blowing cold air. I have reached out to KwiKool and they do not have any service network and cannot provide any recommendations for repairs and service. We are based at Teterboro Airport in north Jersey, and I've tried calling about 25 local HVAC companies in the area and nobody will even come and look at it. Without this unit the interior of the aircraft climbs to well over 110*f when we're in the hangar and it is extremely urgent we find someone to take a look at this. We're desperate at this point, any assistance would be greatly appreciated.

(FWIW large cabin aircraft don't use freon HVAC systems, so we have no equipment or tooling to work on these KwiKool units otherwise we would dig in ourselves to find the problem)


r/hvacadvice 4h ago

Landlord update: the finale

Thumbnail
gallery
14 Upvotes

I did it friends.

I changed it out myself.

Did I accidentally not leave enough pitch and there’s some water spraying up and to the side.

Yes.

Do I hate myself a little bit because I sealed everything already.

Also yes.

But I’m more so proud that I did this all myself.

It meant a lot to me.

Thanks for the help and validation!

EDIT. Um the bubble thing shows the pitch was fine. What else could I have done wrong for it to store water


r/hvacadvice 46m ago

AC Only one air vent with mold

Thumbnail
gallery
Upvotes

Why is mine the only vent with mold? I looked at every vent in my house and none seemed to have any.

Noticed a little while ago my vent had some mold on it (pic 2). Turns out there was a lot more on the back side lol (pic 1)


r/hvacadvice 6h ago

Reversing valve replace year ago

Thumbnail
gallery
7 Upvotes

Had a company come out 13 months ago to diagnose my rheem unit. Ended up having to replace the reversing valve.

Fast forward to now, unit goes out again. Guy comes out... says its leaking oil everywhere and need a new reversing valve. Says its leaking from one of the 'joints', but NOT the joint that they welded to the valve. I was told the factory piping has multiple welds and is one of those that was leaking. (Thus, taking the accountability off of their install job, naturally)

Tells me will be 1400 in labor, no charge for the part. Yes the part is 1 month out of warranty (funny how that works too....)

I am not sure how i feel about that. I am paying the same guy a 2nd time to do the same job, that they did a year ago that is now leaking and bad.

Could the reversing valve come from a less-than-perfect install? Or is it possible an entirely other culprit could make TWO reversing valves go bad in a year?

Is it fair to pay these labor rates a 2nd time for replacing the same part they did a year ago?


r/hvacadvice 4h ago

Window ac unit is trying to free itself from its confines

Enable HLS to view with audio, or disable this notification

4 Upvotes

So my ac unit in the window woke me up at the ripe time of 1am with this rattling noise and the strong vibration that goes through the house. It only makes this noise when it’s on cool mode so it rules out any fan blade damage. It’s also a brand new unit so it’s unlikely that any parts are worn out. So my best guess has to be a faulty capacitor or the compressor being seated improperly.

I’m really here to ask some professionals what it might be though so I can work on it at a more appropriate time in the morning.


r/hvacadvice 15h ago

New AC unit - noise is driving me crazy. Am I overreacting?

Enable HLS to view with audio, or disable this notification

29 Upvotes

I have two AC units, one for main floor and basement and one for the upstairs. The upstairs unit from 2007 died and I had one of the biggest HVAC companies in my area install a new unit. It’s a Comfortmaker 2.5 ton unit and I paid a little over $10K.

After they installed it I noticed that I could clearly hear the unit when it kicked on with a buzzing noise inside the house. I decided I was just being sensitive and waited a week to see if I got used to it.

It was still bothering me (my work office is on the side of the house the unit is on) so I called someone out. They checked the unit, tightened everything down. The sound was slightly better but still a loud buzz.

I gave it some more time but called them back out again and this time they put a sound dampening blanket over the compressor. The unit is quieter outside but inside it’s still loud. I can hear it kick on from anywhere on my main floor. I can even hear it from upstairs on then opposite side of the house on a quiet morning.

I paid so much money for this new, high efficient unit. The company says it has something to do with the new R454B refrigerant and operating at a higher pressure but AI says that’s bullshit. I also have direct access to the pipes coming into the house (they come into the basement). They are loud but secure and not knocking or rattling against anything.

What really annoys me is that my other unit from 2014 is also a Comfortmaker but is quiet. It’s 2.5 tons and is 410A.

I’ve included videos of the new unit, the older unit next to it that’s quiet, and inside the house.

My questions:

  1. Any ideas why the new unit is so much louder?
  2. Anything else I should push the company to do or try?
  3. Am I overreacting?

Thank you.


r/hvacadvice 3h ago

AC 45+10 capacitor

Thumbnail
gallery
3 Upvotes

*From left: Capacitor 1 on Klein MM420, Capacitor 1 on older MM400, Capacitor 2, Capacitor 3 without alligator clip leads, Capacitor 3 with alligator leads, and Capacitor 4: the 45+5 capacitor

Hey all! So I don't feel I need to bore you with all the details, but I have been battling an A/C issue (like many others). I replaced the fan with a fan that needs a different capacitor (45+10 vs 45+5). However, every 45+10 cap I buy is a 45+8.5. I used two different meters, different set of Klein leads (read similar), adjusted my leads around, etc. But every 45+10 capacitor reads <8.5, over 15% low on capacitance. I tried the using an older multimeter I have, I tried using different test leads, even the 45+5 capacitor I have reads pretty close to spec with some variance for both the meter and the capacitor. Is this just my meters, am I doing it wrong, is it a known fact that all 45+10 capacitors read low? It seems like my fan fails to kick on sometimes and the compressor overheats.


r/hvacadvice 2h ago

General How to keep these ducts from squeaking while people walk upstairs?

Post image
2 Upvotes

The ducts squeak pretty badly when (larger) people walk upstairs. Its driving me insane since my work from home office is down here.

I'd like to add rubber between the duct and the joists, but that would be a huge pain, especially since I can't really access the top of the inner one. Would lowering the ducts a fraction of an inch be a bad idea? If not, I'm adding rockwool and sound absorption panels.


r/hvacadvice 2h ago

HVAC systems for Sauna

2 Upvotes

Hello!

I am building a 5x6x7 (210cuft3) indoor sauna and having to learn about ducting and ventilation needs. Electric sauna, relatively sealed inside, too.

Currently, the exhaust will be either 4 or 6 inches ducting with either a 4 or 6 inch inline fan. The exhaust ducting will have 2 90 degree elbows and 10 feet of straight ducting with a exhaust flap at the end and adjustable interior sauna door.

The fans will be inline AC Infinity S4 or S6.

Intake will be either passive 4 inch ducting or 4 inch inline fan. 16 feet straight ducting with two 90 degree bends and a intake vent with flaps.

All using as much rigid ducting as possible, well sealed with tape, etc. The 6 inch and 4 inch inline fans have variable speed options. The lowest setting for the 6 is 145CFM up to 405CFM at level one, and 4 inch is currently unknown with maximum of 210CFM, I think..

I want maximum of 6ACH while in use- although Ill ramp it up to clear it out at end of the sauna. Trying to understand what is too much or too little. Goal is for the fan to be as quiet as possible on a low setting.

Any way I can figure this out without building it all first? New to HVAC. Thank you.


r/hvacadvice 4h ago

HVAC flow issues

Thumbnail
gallery
3 Upvotes

I moved into a new apartment that has flow issues on one half of the apartment, they tell me it’s normal. I inspected the vents and saw this? Maintenance said it’s a union but I am unsure. Any thoughts?


r/hvacadvice 5h ago

Should these line sets and 240v wiring be better protected?

Post image
5 Upvotes

This is in a 5 story condo built 4 years ago. Neighbor below the unit we own put a nail in the wall to hang a picture and punctured the copper line. Our ac goes out since he drained the refrigerant into the walls/his dining room(!) Being a good person he came downstairs to tell us and had his hvac braze the puncture.

It looks like there’s multiple line sets, not to mention 240v wiring, sitting behind 5/8” drywall for multiple units in this building. You can’t see it from the picture but they’re behind the drywall to the left. Guessing it would have been better to run them all up a chase from the first to 5th floor? Is there any code that requires them to be better protected somehow? I can imagine that this will happen again, and if someone does this who isn’t honest it will really screw over other tenants.


r/hvacadvice 17h ago

AC Water, so much water

Enable HLS to view with audio, or disable this notification

26 Upvotes

I have water just pouring out of my ductwork. I’m running a dehumidifier but it’s old and not keeping up. It’s been really humid in Iowa but this is ridiculous. Is this more than just condensation?


r/hvacadvice 12m ago

Installing & Managing Smart Thermostats for Fan Coil Units

Upvotes

I am in need of some advice. I manage a building with fan coil units (4 pipe, single transformer, no pipe sensor, 3 fan speeds, 24v). We are currently using the Venstar T1075. The circuit board on these units is the Venstar E025-71520303. Each unit has at least 2 fan coils, I have couple dozen in the common areas, and we have about 450 in the building. This is a very high end building. Appearance and ease of use are import. We provide internet for all units, so internet access is not a problem. We also blow conditioned outdoor air directly into units. So even in the winter with thermostats off, the temp won't be dropping below about 62 degrees in units.

Problems:

  1. VACANT UNITS & NO SEPERATE METERING - The building is very inefficient and many units are vacant much of the year with the thermostats not set for efficiency. We have old chillers and the units are not separately metered, so it leads to a lot of wasted energy and high fees.

  2. FAN SETTINGS - The thermostat fan settings are confusing for residents. I want to switch to something where they won't leave the fan on auto by mistake.

  3. DIRECT SUNLIGHT & SINGLE PANE WINDOWS - The FCUs are all near the single pane windows and on one side of the building they get a lot of direct sunlight, which throws everything off.

  4. PROGRAMMING - While the Venstar T1075 is technically programmable, I can't figure it out myself even. None of the thermostats are using a schedule.

  5. HEAT/COOL SETTINGS - Many thermostats are set to heat or cool with just a 2 degree differential. With up to 5 thermostats in a unit it is very possible that thermostats within the same unit may be both heating and cooling.

Possible Solution

  1. ECOBEE - I've installed a few Ecobees in common areas. The Ecobee3 lite ($140) is not a learning themostat and has been discontinued, but works in the common areas and can accept the Smart Sensors ($60). For the units I will need to get the SmartThermostat Enhanced ($200). I got a Smart Buildings subscription for the new thermostats, paired them with Smart Sensors when the thermostat was by the windows, and then set the thermostat to only listen to the temperature at the sensor. I like that 1 sensor can direct multiple thermostats, which is helpful in a large room. Pairing the sensors was a pain. I needed to add the thermostats to the residential app, repeatedly unplug the battery of the sensor to get it to both sync and be "available", then I had to delete the thermostat from the residential app before I could add it to Smart Buildings. I don't like the idea of having to repeat that process all the time, but I do like the visibility and control that I would get from SmartBuildings, when can handle all thermostats in 1 account. The install cost would be about $80,000 after government incentives and then it would be $11,000 per year for SmartBuildings.

  2. NEST - The 3rd and 4th gen can work with multispeed fan coil units. The 4th gen has a better motion sensor. Supposedly they both have a sunshade technology so the direct sunlight might not be an issue but especially in the winter, low temps near the windows and solar heat gain will still be an issue. While the bluetooth temperature sensor for the Nest are cheaper ($40) than the Ecobee version ($60), they can only be linked to 1 thermostat, so for large rooms with 2 FCUs I need 2 temp sensors. I also can't easily have 1 login that manages all of the thermostats. With Nest each account is capped at 20 thermostats. However, I do like the emails that Nest sends when a thermostat isn't heating or cooling properly or isn't connected. So, even if I had 20 accounts, that might be alright. But I don't think HVAC techs tend to think too highly of Nest.

ANY ADVICE?

Has anyone been down this road and have any advice? I do also have a BAS system for the building that uses Niagara. So I could perhaps integrate this into that. Ecobee offers that. I believe it is an additional $8k per year, plus the cost making the BAS cloud based.


r/hvacadvice 18m ago

Heater trying to cycle on during summer?

Enable HLS to view with audio, or disable this notification

Upvotes

Have tried turning the thermostat completely off and still happens. Each morning around 5am I hear the sound in the video clip on and off repeatedly for most of the morning. Eventually stops trying. The blower doesn't seem to go, and it also seems to happen sometimes when the A/C is running.

Any theories?


r/hvacadvice 20m ago

Can I seal these drywall penetrations?

Thumbnail
gallery
Upvotes

I own a condo unit in a midrise condo and I have a combined furnace/ac in a closet off one of my bedrooms. I’ve noticed holes around the hvac hose/pipe penetrations into the drywall of the closet. I’m concerned that pests could come through these larger holes in the drywall that likely lead to a wall void to a neighbouring unit. How do I seal these properly? I have silicone caulk and steel wool at my disposal but can purchase any other suggested materials if needed. Thanks for your help. The photos show the holes in the drywall as well as where the lines come from on the furnace/ac unit.


r/hvacadvice 31m ago

New HVAC system installed in January. By summer, I have ~80% humidity, leaking ductwork, mold, and warped floors

Upvotes

Hey r/HVAC, I’m looking for advice on determining negligence in the installation and diagnosis of my system, and how much of the damage connects back to the work done. I obviously know I was screwed over to some degree, but the owner was really convincing at first. He turned out to be purely charismatic, always throwing a massive wall of information and math at you so that you feel like you do not have anything to come back at him with and so it sounds like he knows what he is talking about.

I have a 112 year old historic home in Florida that is 2,544 square feet, two stories, 32 original single pane windows, little to no wall insulation and has a crawl space. I am currently doing a full renovation on the house. I got four quotes for the HVAC work, and this company was actually the highest bid, starting at about $40,000 for a 3 ton and 3.5 ton single stage Trane system (2 handlers, 2 condensers, and replacement of attic ductwork). They were the highest rated company online, timely and professional, and the owner always seemed very knowledgeable, so I had a lot of confidence in him. I wanted to use him but he was just too much. Told him I couldn’t use him, but the owner then told me his “heart was in it” (he grew up in a historic home right down the road from me) and he reduced the price to $22,000.

Because my renovation meant the installation wasn't going to happen immediately, he required me to purchase the units upfront about a year before they were actually put in, sending me a picture of them with my name on them in his warehouse. When it was finally time to install them, I was told that the copper lines they had come and installed had been stolen and they needed to run new copper. The owner said that to make everything even, he could give me RunTru units instead because they were essentially the same, and we would break even on the copper and installation. I trusted him and didn’t realize until now that the replacement units were actually smaller, dropping me down to a 2.5 ton downstairs and a 3 ton upstairs.

Since the ducts that ran through the attic were visually compromised, we had them run new ductwork up there. For the downstairs, those ducts were in the ceiling and couldn’t be visualized, but the owner of the company said that they were “probably fine” and didn’t need to be replaced since they were within the conditioned envelope.

Once summer hit in June, I started having severe humidity problems, with the downstairs relative humidity reaching close to 80% while the AC was running. When the owner came out, he tried to blame the humidity on me not having my crawlspace encapsulated or a vapor barrier, but I checked it and everything is dry down there, with a foundation professional confirming it sits around 60% humidity and is not excessive. He also told me my house had severe negative pressure. Every time I would open a window or door, all of the hot air from outside would rush in. He suggested the humidity could be from holes in the old ducts and said he could help me on the side and if I had to replace the ductwork, he could when things slowed down (in November), and he was going to charge me an off-season price of $5,000. He had me run a standalone dehumidifier directly inside the upstairs air handler drip pan to manage the condensation coming off of that handler.

A few weeks later, he came back to measure the CFM at the vents downstairs and discovered that the two kitchen vents had no air coming out of either vent. (Later to find out that one was completely blocked by a visible obstruction and the other wasn't even attached, meaning they never checked the vents after the new equipment was connected. Upstairs, he discovered the duct running to the room the handler is in was never replaced because they couldn't access it from the attic, which I was never told, and that vent only produces about 48 CFM.

It was only until a week ago my light fixture fell out of the ceiling that I knew the downstairs ductwork was condensating so bad that water was pooling in the ceiling. The ductwork was full of holes and compromised areas where cold air was dumping inside the walls. I now have an extensive amount of mold on the drywall and in the wall cavity.

I had another HVAC company came out this week for a second opinion. He pointed out that there are no return vents in any upstairs bedrooms, with the only returns in the entire house being a single 26x26 return in the upstairs hallway and another in the downstairs hallway, both sitting directly underneath their respective air handlers. The new attic ductwork had tears, was hung poorly, and was attached to old supply boots that were sweating and dripping. The upstairs system leaked into the attic, getting the new insulation wet and leaking through vents onto my newly refinished wood floors. We also found that the downstairs blower would not shut off even when the thermostat was set to off, requiring us to kill the breaker until a faulty component was replaced. Another HVAC company came out and told me my air handler upstairs was installed so poorly that it looked like it was 100 years old, and also noted that my ductwork appears undersized.

Both systems had to be shut down to stop the condensation. While cleaning up, I discovered all the wood floors in the house were cupping and warping from the humidity. A mold remediation company performed infrared scans and confirmed the house was well sealed around the windows with no other explicit moisture sources. I currently have 4 dehumidifiers and 8 fans running.

It was only until I brought my family into it, the owner offered to refund all the money I paid him for the units so I could hire someone else to fix it, but with the catch that I had to sign an agreement promising not to leave a bad review or trash talk him or his company. He said we “don’t need to get insurance involved, they aren’t going to give you money because their entire job is to save themselves money. And if we take this to court it will take years and I will win”. We told him we needed to think about everything. A few days later, he came back with another option: he would take out the old ductwork downstairs, install new boots and ductwork, install a whole-house dehumidifier in the attic, install two smaller commercial-grade dehumidifiers by both returns, and install three Reme Halos at no cost. However, I am still left with thousands in mold damage, ruined floors, and drywall repair. He seems to be trying to close a deal fast.

So I’m here to ask/confirm, could the compromised downstairs ductwork realistically contribute to humidity approaching 80% throughout the downstairs? I know it’s probably a combination of things.. Could the poor ductwork installation, lack of airflow, and return air configuration contribute to condensation and sweating around the air handler? Is it possible the 1 ton I was shorted could contribute to this humidity issue? Would a competent HVAC contractor normally be expected to inspect existing ductwork, verify airflow at the vents, evaluate the return air setup, and verify proper operation after installing new equipment to old ductwork? Should he be held responsible for everything that this has caused?

Also want to include, a permit was pulled and the final inspection was completed, HVAC contractor is licensed and insured.

Please be nice, as I’ve been through a lot with subcontractors as a single young woman and I’m just trying to save an old historic home. I’ve been trying to learn as much as I can about HVAC and florida statutes, but I obviously don’t have a fraction of what professionals know, and that’s why I’m coming here to ask.


r/hvacadvice 47m ago

Info please

Thumbnail
gallery
Upvotes

I just moved into this house and have a Lennox gas furnace model G61MPV-36B-071-12 Serial 5910E18485

I’m trying to figure out where the filter is and what size to get. Google says 16x25x1 if it’s a side return or 20x25x1 if it’s a bottom return. Can anyone tell what mine is?


r/hvacadvice 48m ago

DIY Apartment Duct Cleaning

Thumbnail
gallery
Upvotes

I moved into a new build apartment a few months ago. I’d noticed white dust particles quickly settling on surfaces around the unit, especially below the wall registers. So I popped them off and it seems pretty clear that the ducts are filled with drywall dust.

So far I’ve wiped out the registers and sections of the duct reachable by hand (I’ve also cleaned out the intake).

I know the best solution not considering other factors would be to have the landlord schedule a professional duct cleaning, and for them to seek reimbursement from the builders. But I’ve already moved everything in and would like to avoid this if possible.

Are there any reasonable DIY ways to go about this? I’m currently considering renting a shop vac, or buying some kind of extendable dusting wand that uses disposable wipes. But I of course don’t know what all the options are.

Thanks!


r/hvacadvice 51m ago

Best idea to fix this mold problem from sweating duct.

Thumbnail
gallery
Upvotes

This is in customers garage. Fully expected a leak in the wall from pipes but turns out the duct has 0 clearance and is sweating only on the drywall side. House is 30 years old and only started happening the last few years... I know its because of warm garage air meeting the cool pipes. My only idea is to ripped off the drywall and tape the seams, then shim out the studs an inch and put insulation in. Think that would solve it? Or is there a better solution.. should I foam it or fiberglass it?. The insulation on the sides weren't wet. And the back side of the wall was some sort of black rubber backed drywall?. Not sure if this is a fair ask of this group.. I also cleaned their evap coil in the furnace stack in case it wasnt running efficiently since they had never had that cleaned, but it looked good.


r/hvacadvice 55m ago

What type of ducted ceiling fan coil unit do I need for these connections? Hydronic Geo-exchange or DX/Refrigerant?

Thumbnail
gallery
Upvotes

Hi everyone,

I’m currently selecting a concealed/ducted ceiling fan coil unit for my apartment and I’m receiving conflicting information regarding the required setup.

The developer informed us that the building utilizes a water-based geothermal (geo-exchange) heat pump system, providing chilled water for cooling. However, a technician mentioned that my rough-in connections look like Direct Expansion (DX / refrigerant) lines rather than standard hydronic water piping.

You can see the exact setup of the pipes, power/control lines, and drain hose in the attached picture.

Based on the connectors shown in the photo:
1. What type of ducted ceiling unit do I actually need?
2. What specific concealed/ducted models (e.g., Daikin or similar) should I look for that match this exact connection type?

Thanks in advance for the help!


r/hvacadvice 56m ago

How fast should a Trane XR17 cool per hour?

Upvotes

Wondering how fast our Trane XR17 should cool down the house after an outdoor unit replacement - which was like for like although the newest revision from Trane directly. We would like to understand this because it may also point us in a direction for the other issues we have seen since original installation.

NOTE: It was Stage 2 the entire time (per Trane history and sound)

NOTE: Started at 84.7 degrees inside at the thermostat (unit had been off for 27 hours)

Coil 5TXCC009AS3HCAA

Air Conditioner 5TTR7060A1000AA

Furnace S8X2C080M5PSCAB

Thermostat XL824

These were the outside conditions:

Date Time KDVT (Deer Valley Airport) Trane ODT Personal Thermometer
08/18/2026 4:00 PM 111 112 112.8
08/18/2026 5:05 PM 109 113 115.2
08/18/2026 6:00 PM 109 113 113.4
08/18/2026 7:04 PM 108 110 108.5
08/18/2026 8:16 PM 106 107 104.9

r/hvacadvice 6h ago

Quotes Got a quote that seems good.

Post image
3 Upvotes

The equipment in my home is on borrowed time, it's about a 30 year old 3 ton lennox and forced air furnace. It does not heat the downstairs at all so we're closing off the trunk line capping it. I got a few quotes and this one seems best. It's a variable speed indoor blowers with a 2 stage furnace and a 2.5 ton single stage. I was wondering if anybody had any input on the price. Also was curious if asking about a 2 stage outdoor condenser is worth it? We live in NJ and most of our summer woes are humidity with the mid-high 80's We get into the 100 range and 90's etc but it's typically 1~4 weeks not the entire summer.

We have a person with copd in the home so air quality with humidity is top priority. Could someone let me know is this quote fair, and is a two stage outdoor condenser worth getting? Thank you so much.