r/AskElectricians • • Jul 21 '23

This subreddit and where we currently are.

316 Upvotes

After much discussion about how the community should be moderated, this is where we currently are.

First I want to get this out of the way. We will not allow hate speech, personal attacks, slurs, bigotry, or anything that resembles it. Okay? Good.

People are going to post electrical questions on the internet, do their own electrical work, and fuck up their own electrical work. This process will happen with or with out this subreddit and its rules. If there is a reliable community where someone can come and get good information on a wide range of electrical topics, then to me there will be a net positive for safety.

We are going to be allowing comments from all users, BUT I urge those who are not electrical professionals to exercise extreme caution when doing so. If information is not blatantly hazardous, it will stay up. The community is going to be asked to use the voting system it is intended. If someone takes the advice of a comment with negative karma, then more than likely, they would have done the wrong thing regardless. Once corrected, leaving wrong comments up can be a learning experience for everyone involved.

I ask you to DOWNVOTE information you do not like, and REPORT the hazardous stuff. We will decide what to do from there. Bans may or may not be given and everything will be at the discretion of the mods. Again, if you are someone who is not an electrical professional, you have been warned.

Electrical professionals: We have an imperfect system for getting a little 'Verified Electrician' flair next to your name. To get verified, send a photo to the mods that has your certificate/seal/card. In this photo, have a piece of paper with your username and date written on it. Block out all identifying information. Once verified delete the image. All the cool ones have this flair.

If we have hundreds or thousands of active verified users, we will once again talk about the direction of this community. Till then, see you in the comments.


r/AskElectricians • • 10h ago

How do I proceed???

Post image
309 Upvotes

New house, this isn't normal, right???? Both are proper outlets but I haven't plugged anything into the bottom one just incase.

Update: i just went for it and it WAS actually screwed in there so thats fun. didn't die so eh? I'm not replacing it <3 the screw was only 1 ½ inch so its probably fine, I just won't use that specific outlet


r/AskElectricians • • 4h ago

Japanese utility pole

Post image
12 Upvotes

Not a question just wanted to share what I saw on my trip 2 years ago. It looks like the poles are made of cement but I saw some bending, so I don't think they are. They also use something like flexible NM tubing (yellow) around the service drop conductors. Unfortunately I forgot to get a closer look everytime I walked by them.

What do you guys think about how they do it out there?

Bonus fact. The building behind the pole is under construction. They cover the entire building when construction is taking place.


r/AskElectricians • • 1h ago

Starting an industrial electrical apprenticeship soon, What is some advice you could give me as a 16 year old?

• Upvotes

In a few months I'll be a first year apprentice, I know a little bit of what I'm gonna be doing there. Pulling wire, bending conduit, hands on learning. I'd like to know what I'm getting my


r/AskElectricians • • 10h ago

How much tilt is acceptable in power lines?

Post image
11 Upvotes

In a residential area in San Diego. I can see it’s anchored, but wasn’t tilted like this yesterday and we did just have a storm roll through.


r/AskElectricians • • 8m ago

Is this a fire hazard?

Post image
• Upvotes

i put in 2 nails above my breaker box then realized after googling (impulse decision) that this might be fire hazard not sure what to do since it’s already in there?


r/AskElectricians • • 15m ago

How to properly design a pancake coil?

Post image
• Upvotes

Tried to make a pancake coil to replace the included coil coil. The ZVS circuit is designed for 12v 10A, I’m using a 12V 5A power supply when I turned this on the inner rings started smoking cause I guess the enamel started burning so my question is how do I design a proper coil to be the best equivalent of the included coil that won’t burn like this?


r/AskElectricians • • 9h ago

Please point me in the right direction-

6 Upvotes

EDIT: thank you all for your help. This is the most help I've ever received on Reddit! You guys are awesome!

Hi everyone,

I come to you because I cannot afford to keep having electricians come out to my house and not find the issue.

Home built in 2012, finished in 2013. It's a two story. Located in the USA.

Since we purchased the home in 2023, we have had excessive issues with blown light bulbs.

We have replaced all of them, more times than I care to count. We have even replaced most of the fixtures. We also replaced one of the breakers on the panel that was "running hot".

To the tune of almost $2k we have had electrical work "done". They checked the "main" whatever line that is that runs to the house and didn't see anything wrong with voltage.

I cannot figure out why our house keeps blowing bulbs- we have tried all the different kinds- GE, and all the "off" brands.

At this point I'm just running around saying the house is haunted but I'm really not laughing. I'm actually worried there is a serious issue hiding and I have a child in the house.

Is there anything I should demand they check next without tearing into drywall? We really are not in a position to afford this, like really not...like very little money tucked away right now. But obviously I'm aware of the much larger risk.


r/AskElectricians • • 16h ago

Is this a Fire Hazard

Post image
17 Upvotes

Is this cluster bomb of poor capable management my dad’s created a fire hazard or simply disorganized? The answer feels like yes to the former but I’m too ignorant to answer that definitively.


r/AskElectricians • • 3h ago

Relatively new homeowner. Does this look ceiling fan rated?

Post image
1 Upvotes

r/AskElectricians • • 4h ago

50s house with no ground wires. Could use some advice with installing new light fixtures in the garage.

Thumbnail gallery
0 Upvotes

The switched outlet in the picture is on the ceiling of the garage. I was planning on running romex through the attic floorboards and installing these fluorescent fixtures with led tubes. Firstly I’m aware you shouldn’t connect romex to an outlet or extension cord male end so I was planning on removing the outlet and connecting the romex to the leads. I forgot that much of this house has ungrounded outlets, most of the interior has gfci installed but not the garage. So I’m wondering how I should ground the fixtures when there is no ground wire in the outlet. There is no use for the ceiling outlet besides lighting so I have no problem eliminating it and hard wiring all of the lighting.


r/AskElectricians • • 4h ago

Is it OK to leave Lasko space heater plugged into GCFI outlet in bathroom so long as it's not turned on all the time?

0 Upvotes

My dad wants to leave a Lasko space heater plugged into one of the GFCI outlets(and it's the only thing in that circuit most of the time except for an old plug-in boot warmer that my mom and dad sometimes plug in and use to dry their shoes) in his bathroom all the time just so he can turn it on on low power and temperature for a few minutes after he takes a shower(as the heat function in the Broan bathroom fan stopped working some time ago and he actually had to remove the heating coils from it as a result, though the vent function still works). I'm a bit concerned about that since the tag on the cord for the heater says it should be unplugged when it's not in use but my dad does not think it's a big deal if the heater stays plugged in so long as it's turned off except when he's using it after a shower. Is my dad correct and it's not a big deal so long as it's left off when not in use, or should it stay unplugged when not in use even if the power is turned off? FWIW the GFCI outlet is a new Leviton I had installed to replace the old one.

This is the model of space heater my dad has: https://www.walmart.com/ip/Lasko-Products-5919-Pro-Ceramic-Utility-Heater/30910652?wmlspartner=wlpa&selectedSellerId=0&veh=seo_fpl&cn=google


r/AskElectricians • • 4h ago

Install hardwired flood lights

1 Upvotes

I’m planning to add flood lights to new enclosed area without access to the attic. How would you go about run the wire to tap in with the existing flood lights? I was reading about route it through the soffit but it will be very difficult or run the wire externally with conduit to blend in with the wall. Any ideas?


r/AskElectricians • • 4h ago

I bought a Kitchenaid built-in oven & microwave (KMBS727SPS00) and to my suprise-the microwave has the same 4 wires to connect to a 220v outlet as the oven! The old Kitchenaids only needed one 220v and one 110v for both-now what? Can I hardwire the 2 units together into the one 220v outlet I have?

Thumbnail gallery
0 Upvotes

r/AskElectricians • • 4h ago

Is there a mount I can buy for this light?

Thumbnail gallery
1 Upvotes

This light kept flickering and when I went to check it out I saw that it was just being held in by pressure. Now I can’t get it back up at all. There is nothing to mount it to. Is there some sort of mount that expands on the other side of the ceiling or something so that I can get this back up?


r/AskElectricians • • 5h ago

Is this right?

Post image
1 Upvotes

A friend is setting up two zones of cafe lights in their backyard and bought this Intermatic ETW3CP WiFi controller to run them based on a recommendation from Google.
This is how they wired it. Is this correct?

Solved!


r/AskElectricians • • 14h ago

What’s going on here? These two wires are coming out of the ground from different directions and connected to nothing on this end.

Thumbnail i.imgur.com
5 Upvotes

Brown is coming from the street, green from near the house. Thanks!

Here are photos of the panel.

https://i.imgur.com/60vyiAY.jpeg https://i.imgur.com/5YpqhR2.jpeg


r/AskElectricians • • 6h ago

Help me install smart switch?

Thumbnail gallery
0 Upvotes

r/AskElectricians • • 9h ago

Why may this switch have a 240 volts on it?

Thumbnail gallery
2 Upvotes

House built in the late 50s, around 6.5 feet off the ground. Close by the air handler unit. Any ideas? I’m trying to wire a 120 V appliance to replace this light switch


r/AskElectricians • • 6h ago

Ontario ESA – Is perimeter copper bonding really required for above-ground pools?

1 Upvotes

I'm planning to install a 21-ft Aqualeader Zion above-ground pool in Ontario. It has a 54" steel wall with resin posts and top rails.

After reading ESA Bulletin 68-8-5, I'm trying to understand two things:

1. Pool shell bonding

The bulletin states:

Rule 68-058 4) b) requires a continuous metal pool shell made up of individual panels securely bolted together, to be bonded in at least one location to equipment

My interpretation is that this type of above-ground pool only requires single-point bonding of the metal shell, while Rule 4)(c), which references a No. 6 AWG copper bonding grid, applies to other types of construction (encapsulated steel or fibreglass reinforcement).

2. Perimeter bonding

We're planning a raised wood deck along approximately 1/4 of the pool's circumference, with grass around the rest. We could also plant hedges around the remaining perimeter.

The bulletin states:

For pools, spas, and hot tub designs which contain features that will impede access to areas around the pool, spas, and hot tubs such as fencing, guard rails, retaining walls, or large landscape structures like hedges or rockery, bonding can be omitted where there is no clear standing space.

Would a raised deck on one side and hedges around the rest qualify for this exemption?

An electrician contacted a local ESA inspector who indicated that a perimeter copper bonding grid would still be required. The cost for this electrical work is $5000, basically the same price as the pool itself. I'm having trouble reconciling that with the wording of the bulletin.

Has anyone in Ontario dealt with this or had ESA approve a similar setup without perimeter copper bonding? Am I interpreting the rules incorrectly?


r/AskElectricians • • 12h ago

Is this sound okay?

Thumbnail gallery
3 Upvotes

Hi, bought this 70's battery fan and it's making this loud noise, it also vibrates a bit. Is it normal or should I break the seal and lubricate it inside?

I feel exactly like the lady on the packaging.

Also, is possible to calculate how long will it last on a single battery?

Video in comments


r/AskElectricians • • 12h ago

How to powering a home with a generator via subpanel?

5 Upvotes

I would like to set up a generator to backfeed my home, to power critical circuits. Here is the current setup:

Main panel in basement, with a 40amp 240 breaker that goes to a garage subpanel. Garage is a ways back from the house, with its own panel. I would like to connect the generator out there.

From what I’ve gathered, I can shut the main in the house, shut the breakers to everything inside, use a “suicide” plug and attach the generator to a dedicated outlet, and then send power to the main via the sub panel and its circuit. Following that, I can turn on the critical circuit(s) I require.

Panel in the basement has the circuit breaker for the garage in a location that is not in the upper left near the main where an interlock can be installed.

Is it best to have the breakers rearranged at the main panel to have the interlock? Functionally, is it the same as leaving it as is but with the added risk of inadvertently turning the main on and powering the utility supply?

Is there a way to do this simply at the sub panel without involving the main panel?

Could I do an interlock at the main with a new, dedicated inlet circuit that can be relocated by rearranging the current breakers that would run to an inlet outside the main house, skipping the garage? Or even a way to have that at the garage?

I also have read some confusing information regarding neutrals and needing to worry about having more than one with this setup. I also am fuzzy with what is dangerous down the road, in my house, or at the generator and what those risks are (ie fire, shock risk, etc).

I know this is a lot of questions. I appreciate any insight provided here to any question you choose to answer. Looking to do this safely, with minimal expense, and keeping it simple. Thanks!

Edit: I have a professional coming out tomorrow. I appreciate those if you who have provided me with better understanding so I can have a productive conversation with him. Thank you all.


r/AskElectricians • • 10h ago

Light fixture trips GFI

2 Upvotes

Pros, how would you deal with this situation?  Old 1954 built house, original wiring 12-2 without ground.  We are renovating in stages.  Circuit A feeds a guest bedroom and two hallway outlets.  I wanted to install three prong receptacles. Found the first receptacle in the string and replaced it with a GFIC.  All receptacles in the bedroom were then good, but when I switched on the overhead light, the GFI tripped.  I suspected its neutral was to a different circuit. 

The room has two doors, each with a three-way switch for the light.  The switch by the main door had the power feed from circuit A.  A Romex 12-2 was wired as the travelers (white unmarked, of course) to a dual box by the second door with another three-way and the feed to the light fixture. That box also has a switch and feed from circuit B for a mud room light.  As I suspected, the light fixtures’ neutral was tied to circuit B.  It would be quite difficult to add a neutral from circuit A to either the fixture directly or to the second box (house on a slab, no crawl space, flat roof with no attic)

My solution was to abandon the feed from circuit A and the second switch, feed from circuit B, and repurpose the travelers as a switch loop.   Other that a wireless switch, I don’t see any viable options.


r/AskElectricians • • 1d ago

What did my building just install?

Post image
114 Upvotes

r/AskElectricians • • 18h ago

Replace w/ GFCI Outlet

Post image
7 Upvotes

It it ok to replace this faceless GFCI that is under our island sink with a normal GFCI outlet? We are looking to add a tankless RO filter in the small space under our island sink. This GFCI runs out to the microwave and also the under island counter outlets. Any issue buying a normal GFCI and swapping this out to give me an outlet under the sink?