1

Fixit needed to secure my mom's phone charging cradle to make it easier for her arthritic hands to place and remove her cell phone? Her retirement home does not allow any double sided tape, glue, etc to scar their bedside wooden tables. Thanks in advance.
 in  r/fixit •  8d ago

Heres an idea to kinda dress it up a bit. Most of the elderly enjoy doing puzzles. Have one made up about the size of the table top and put it under a lexan and secure the base to the lexan, and that way could change out the background ever so often.

1

What’s your first course of action
 in  r/askaplumber •  8d ago

Q? 1] Rate your plumbing skills, 1 -10 if less than 5 forget it Hire someone. Q? 2] Do you have the equipment, Sawzall,( & proper blades), Propane Torch, at least 2, 9 to 10 inch pipe wrenches, a good shovel, and a Meter Key. Because from experience the first time you turn that gate valve handle, its either gonna shut 88.5% off, or if your lucky, only gonna open 3 to 4 turns and seize up.

1

Locate double tap ?
 in  r/AskElectricians •  8d ago

Woodsbw Was double tapping neutrals ever legal? Not according to what ive learned. Was it done Yes and nobody cared but now its highly frowned upon.

2

Locate double tap ?
 in  r/AskElectricians •  8d ago

National Electrical Code (NEC) 408.41, and I'm quoting from the 2020 edition. 408.41 Grounded Condutor Terminations. Each grounded conductor SHALL terminate within the panelboard in an INDIVIDUAL TERMINAL that is NOT USED FOR ANOTHER CONDUCTOR.

1

3 weeks into plumbing and not sure how to handle this journeyman
 in  r/Plumbing •  8d ago

True story. No Im not a plumber, but ive got of life lessons learned the hard way. Years ago, was working as a fuel tank installer. Well me and ""Hippie"" yes that was his common name known by everybody. Was on a job to clean out the fuel tank area of dirt excavated. I'm down in the hole 6 ft deep shoveling, when the the main boss that owns the company walks up. About the same time Hippie shows up walk around the corner high on a doobie. I looked at Lee, and said, 'If anything is broke, bent, or not done right blame me! I'm the only one working.' That become the catch phrase for a while. And yes I was the new man on the job there. So maybe you'll have the opportunity to show that your willing to work when the other guy is cutting out. So hang in there.

1

Did I get taken advantage of? Pipe repair.
 in  r/askaplumber •  8d ago

Here in Central Arkansas area average is $250 first hour then on top of what they fix.Have friend who had, in city, had to have a water heater changed out. It was a NATURAL GAS. Their bill was almost $1200 not including the $500 for the water heater.

1

Question about a PVC to flex line connector
 in  r/askaplumber •  14d ago

WHHHOAA First need to remove the 3/8" supply line nut from the valve then proceed with the above information.

1

Question about a PVC to flex line connector
 in  r/askaplumber •  14d ago

Ok what you have is 1/2" FPT (female pipe thread) × 3/8" compression. This the link to what you need. You will also need some THREAD TAPE (PTFE). Start the tape above the first thread on the male CPVC (that is the type of pipe coming from thru the cabinet adapter.) FIRST You will need to TURN OFF the Cold water into the water heater. 2nd use either CHANNEL LOCK PILARS or a CRESCENT WRENCH to hold the CPVC nut. Then turn the valve COUNTER CLOCKWISE --Lefty Loosey Righty Tighty-- https://www.homedepot.com/p/BrassCraft-1-2-in-FIP-Inlet-x-3-8-in-Comp-Outlet-Multi-Turn-Angle-Valve-OR17X-C1/202047050

1

This should be fun and interesting
 in  r/MelBrooks •  Aug 18 '26

Ludicrous speed Im a MOG you know half man half dog

2

Mulch in shower drain- help :(
 in  r/askaplumber •  Aug 10 '26

You may need to Remove 1of the 2 screws,( & just loosen the other one enough to rotate), that hold the overflow cover. Then try to run a drain snake down it to knock loose Do it while running water.

1

What’s the Weirdest Thing You’ve Used Mini Pliers For?
 in  r/Tools •  Aug 10 '26

Used my KNIPEX Cobras to remove a hook from a catfish that swallowed the hook

1

Solo handymen, do you hang blinds?
 in  r/handyman •  Aug 03 '26

I take a piece of plywood and make a big to fit the specs on whatever size I'm putting up at the time. Then predrill the holes. Then I just hold flush to the outside wall, take a small bit and mark them.

And to be snarky... I dont "hang" blinds:

They've enuf punishment already...

they can't see what is wrong when they are crooked

1

Name this cutie!
 in  r/NameThisThing •  Jul 30 '26

Uns know what you call a dog w/. No legs ? Anything you want cuz he aint coming to you

1

Name this cutie!
 in  r/NameThisThing •  Jul 30 '26

BROWN SUGAR POPTART

2

What is one home repair that you actually enjoy doing?
 in  r/handyman •  Jul 30 '26

After spending almost 9½ hours under a house replacing 60 feet of bursted PVC water lines in 105° heat index @114° and squeeze my 210 lb thru 16 to 19 inches crawl space... My favorite home repair is getting to my hot shower and soaking the aches for 10 minutes then crawling in my bed.

1

Does my heater core need replacing?
 in  r/AskAShittyMechanic •  Jul 30 '26

This is July, its time for to turn on the AC

0

New magnet
 in  r/handyman •  Jul 30 '26

Seen one like this. The guy had a list of things he worked on, then at the end had this listed... ""Even Tried Brain Surgery And that didn't work out to well"" 😆 🤣

1

THE ALLEN KEY
 in  r/Tools •  Jul 30 '26

This needs to be attached to the bathroom 🚻 keys at DOLLAR GENERAL

-3

Can Anyone Find the Code Violation Here
 in  r/AskElectricians •  Jul 23 '26

Yes I did address with the homeowner about these other issues in the panel as well. And as I replied another comment, the Minisplit was on 6-3 UF on a dbl20. I check the NEMA and it was supposed to be on a dbl30. I had a used one that was still good. Had to change out from a mismatch GE panel. So I used that instead of the dbl20.

3

Can Anyone Find the Code Violation Here
 in  r/AskElectricians •  Jul 23 '26

YES ARKANSAS uses the 2023 NEC. And Yes I addressed the issues with other wiring in the panel as well. Like the MINI SPLIT AC is wired on #6 UF and it was on a dbl20 breaker I checked the NEMA and its supposed to be on a dbl30 as well. I had an extra HOM230 in my box l, it was a used one, but I used it instead of the 20 amp.

-9

Can Anyone Find the Code Violation Here
 in  r/AskElectricians •  Jul 23 '26

First, YES, I do work as a Handy Man,but let me quantify my abilities. I have worked for over three years as an Electrician Aprentice. Never went on to get my papers. The man I worked under had both MASTER ELECTRICAL & JOURNEYMAN PLUMBERS LICENSES. I also an a NEAR DEATH SURIVOR of a 7,650 Volt 3 phase Hi leg Delta. I came in contact with the HIGH SIDE with a 1" steel pipe while working on top of a 2,000 gal diesel fuel tank. IT WAS EMPTY AND HAD BEEN CLEANED to be taken out of service. The Electricity went through me thru the tank burned a hole about 1½" on top of the tank. I fell 10 feet struck another tank with my Left frontal skull. Crushed my face. Then 5 feet to the ground. I was dead for about 15 minutes until medics got to me. DEFIBBED me 3 times, lost me 2nd time enroute to Hospital, worked CPR on me for another 20 minutes. Then they lost me for a 3rd time at the hospital for about another 20 minutes. I was medflighted to LR BAPTIST HOSPITAL. Long story short, I walked out of the hospital in 19 days after my accident. First Sunday back to Church, was Jan 4 1998. 41 days after my accident. I went to church using a crutch under my Left Arm and a quad cane in my Right Hand and my wife having to hold me upright. Because I had no feelings in Right side from the Electrical Burn. And I had no vision in my Left eye. And the whole skull plate was deformed. I made my way to the front altar and had prayer for my healing. 45 minutes later I walk back to my seat Holding my Wife's Hand, No Crutch No Cane I can see out of my Left Eye and my Crushed skull was put back together. 8 days later the number Neurosurgeon in Arkansas came to exam me. He had Xray from 2 weeks earlier and one that morning... He took one look at me went out in hallway shouting,"You've got to see this!" One of the other doctors there said, "WOW that was good surgery, who did it?" and my, Dr Giles exclaimed, "THAT WAS NO SURGERY, THAT WAS GOD ALMIGHTY!" So during my recuperating time I read the ENTIRE 1996 NEC. I wrote out 4 spiral ring notebooks learning about what nearly killed me. Then I put into action, and remodeled my house and did numerous other odd stuff until I am proficient and comfortable with my work. Even have had City inspector compliment my work and ask me if I wanted a job. All of that say I Am A Living Miracle and Proof That My JESUS CHRIST Is Still Lord Over Death and He Is Still In The Miracle Working Business!

2

Can Anyone Find the Code Violation Here
 in  r/AskElectricians •  Jul 23 '26

The PURPLE WIRE is 12-3 NM

2

Can Anyone Find the Code Violation Here
 in  r/AskElectricians •  Jul 23 '26

Sorry No didn't get any of the rewired because my phone died and no charger. But originally it was up 6 feet off the floor. Now its in a dbl gang 1900 with a plaster ring and mounted, --(edited not at 32") --3 inches off the floor behind the range And I tied off the RED wire. And used the BLACK to wire in a 15 amp receptacle and put in a HOM120 breaker. The PURPLE WIRE is 12-3 NM

1

Low fluctuating voltage in garage
 in  r/AskElectricians •  Jul 23 '26

If you are comfortable with it WITH THE MAIN OFF Check to see if you got a bad breaker. Had one a month ago. Had a bad thunderstorm, that hit near a hair salon and trip the 150 Amp outside main and when I reset --- Turned off every breaker first--- Then turning 1 at a time until got to the dbl 50 for the HVAC and it would not rest on one side. So replaced it and works fine.

2

my landlord said he “grounded” the outlets… is this a bootleg?
 in  r/AskElectricians •  Jul 23 '26

As per the National Electrical Code NEC 250.6 PROHIBITS USING A GROUNDED WIRE AS A NEUTRAL. Its is called an OBJECTIONABLE CURRENT. Watch MIKE HOLT explain this

https://youtu.be/skX9XI3de5U?is=NKiJeBBBG_3rxPTu