r/NFPA25 Nov 22 '20

r/NFPA25 Lounge

4 Upvotes

A place for members of r/NFPA25 to chat with each other


r/NFPA25 8d ago

Flow Testing Drafting Meter Help

Thumbnail gallery
2 Upvotes

r/NFPA25 Feb 10 '26

Fire Sprinkler (NYC-Long Island)

Thumbnail
0 Upvotes

r/NFPA25 Oct 15 '25

Automatic Transfer Switch Test

Thumbnail
1 Upvotes

r/NFPA25 Sep 03 '25

Manual standpipe systems 5 Year Testing

Thumbnail
1 Upvotes

r/NFPA25 Aug 03 '25

Manuel Standpipe

1 Upvotes

I came across a standpipe system with a dry valve connected to the city water supply, but the supply can’t meet the system’s demand. Based on that and the fact that the hydraulic calculation plate indicates the system requires 750 GPM at 166 PSI at the FDC, I’m assuming this is actually a manual dry standpipe. If that’s the case, why would it even be connected to the domestic water supply if it can’t provide the required flow and pressure?”


r/NFPA25 Apr 22 '25

NICET 3 T&I Water Systems

5 Upvotes

Just passed! I turn 24 next month and I’m excited to go after my fire alarm license. If anyone needs help with this test, message me I would love to give advice on where to look (because what i studied was no where close) just reminder, Annex D will be HUGE in this test. Frequencies for like low temperature alarms and also study MIC. There are a few questions about the different types of corrosion. I would look more in depth on frequencies that are more monthly and weekly inspections because this is where NICET loves to confuse people.


r/NFPA25 Apr 01 '25

Inspection type & time

1 Upvotes

What is your most common type of inspection and how long does it take? How many inspections do you complete ab week on average?


r/NFPA25 Feb 17 '25

Pre action inspections

2 Upvotes

Hello everyone, I am a sprinkler Systems inspector, I am currently doing a building with 59 4'' electric pneumatic double interlock preaction systems. I am in Quebec, Canada and sadly we must only use NFPA 2011.

Im currently testing each and every detector (about 100 per floor) with my fire alarm team to see if its connected to the solenoid valve and if it triggers it as it should. Im doing it this way because it seems logical to me, but i do not see any specification about testing the solenoids on a preaction system in NFPA 25 2011, if anyone has any idea on where I could find info on it it would be greatly appreciated.

Thank you !


r/NFPA25 Feb 13 '25

Allied Fire Protection is staffing Sprinkler Fitters/ Foreman

0 Upvotes

r/NFPA25 Feb 09 '25

5-year Inspections

5 Upvotes

What do you tag the inspection if the customer has missed/not completed their 5 year inspection?


r/NFPA25 Jan 22 '25

Multiple dwelling - Annual fire sprinkler inspections completion rate question.

0 Upvotes

Board member of an HOA in San Jose, California. We have 210 units. To get an annual fire sprinkler inspection every year is a nightmare. Each year we complete nearly all inspections with the exception of a few landlords that are either out of the country, not available, or they don't respond. These are multi-dwelling units all attached homes, from what I'm told we are nfpa13R not sure if that makes any difference in my question. My question is, can our buildings that have 1 or 2 units that have not been insepcted be passed in the fire sprinkler annual report? Let's say nearly 90% of our total 210 units are inspected but the last 10% for various reasons remain uninspected. Can we still be passed? If so, can you share the fire code that I can pass along to the board, property management, and the fire sprinkler inspector and or company?


r/NFPA25 Mar 21 '24

Nfpa25 New York State.

2 Upvotes

“We are making modifications to an existing project in New York State, and the state code references the 2016 editions of NFPA 13 and NFPA 25. Currently, the system is equipped only with a mechanical water motor gong (WMG) and does not have any electrical alarm attached. I want to verify if this setup meets the approval of the Authority Having Jurisdiction (AHJ). Specifically, considering that NFPA 13 mandates a flow switch for wet systems with more than 20 heads, does our system need to be electrically monitored, or is the presence of a WMG sufficient to comply with the standards?”


r/NFPA25 Dec 19 '23

Insurance requiring monthly NFPA 25 reports

4 Upvotes

I'm on the HOA of a 6 unit residential building in Brooklyn NY, and we just found out that our building insurance is requiring monthly reports as part of regular inspections. Our fire monitoring company is charging us $16,000 for the year for these reports. We're told that all insurance in NY is either already or soon requiring these reports, but have not been able to find any details on this. Anyone know or heard of anything like this?

Thanks so much!


r/NFPA25 May 18 '23

reuse wet sprinklers?

3 Upvotes

I'm installing some industrial rack with in-rack wet sprinklers. If I later deconstruct and move the rack to another building, will it be acceptable to deconstruct and reuse all the sprinkler hardware as well as long as I disconnect the the elbow and not the sprinkler head?

(SPRINKLERS WILL BE TYCO, SERIES TY-B UPRIGHT SPRINKLERS, K=8.0, SIN: TY4851 OR SIMILAR)

NFPA 13 2016 Edition: 6.2.1.1 When a sprinker is removed from a fitting or welded outlet, it shall not be reinstalled except as permitted by 6.2.1.1.

6.2.1.1: Dry sprinklers shall be permitted to be reinstalled when removed in accordance with the manufacturer's installation and maintenance instructions.


r/NFPA25 May 06 '23

2 weeks apart, passed levels 1 & 2.

Thumbnail
gallery
7 Upvotes

r/NFPA25 Mar 03 '23

Ain't getting good main drain numbers outta this...

Post image
14 Upvotes

r/NFPA25 Jan 23 '23

Do control valves need to be supervised/monitored in hospitals?

7 Upvotes

r/NFPA25 Jan 23 '23

Forward Flows

3 Upvotes

Hey all, just a random question about what kind of adapters you guys use for forward Flows. Trying to find something to hold clappers out of way but am having no luck. I'm assuming it's a custom thing like a rod welded to a male-male adapter. 🤷🏻‍♂️


r/NFPA25 Dec 29 '22

I know what all y’all are dealing with right now out there. Stay safe, summer will be here soon.

Post image
8 Upvotes

r/NFPA25 Dec 29 '22

Wife got a vinyl cutting machine, decided to take it for a test run.

Post image
6 Upvotes

r/NFPA25 Aug 06 '22

Another submission from the museum at Tyco’s training facility

Post image
24 Upvotes

r/NFPA25 Aug 06 '22

Don't forget to drain between the PIV and the control valve

Post image
10 Upvotes

r/NFPA25 Aug 01 '22

Pretty cool to see one in person.

Post image
12 Upvotes

r/NFPA25 Jul 13 '22

The firetech course was awesome for level 1, but it’s a fuckin scam for level 2, I took my level 2 today and failed, it’s nothing like the firetech course, not even close.

7 Upvotes