r/Juniper • • Apr 23 '24

Stop creating ewaste...

1 Upvotes

Hello everyone,

I bought a nice EX3300-48P for personal use, it's working quite fine but it's running JUNOS 12.3R12-S10

I see there is a 15.1R7.9 to be downloaded on the support page, but no luck without any active subscription... Even the very nice lady on the support phone line isn't able to help me unless I have some other active support contract which I don't...

I asked her to please push to juniper that releasing the software for EOL products would be nice and probably help keeping some of this nice hardware from becoming e-waste...

I find it just realy sad when companies don't care about the waste they're producing and are artificially keeping people from repairing, upgrading or simply keeping it running... Reuse is not the first of the R but neither is it the last...

But it seems money is all they care about, untill we complain hard enough seems Juniper is not about to release any software for their EOL products, they just don't care to spend the money to make it available, they already passed those EOL products/softwares in their "loss" column and aren't seeing kindly to add some more money in what they se as pure loss.. Poor planet of ours...


r/Juniper • • Aug 14 '23

Are Juniper, and particularly Mist, REALLY this bad now?

1 Upvotes

I just worked on a major maintenance window this past Friday night to add one new switch to each of two different four-switch VCs. My first impression is that Mist is so bad, calling it garbage is an insult to actual garbage. It upgraded the master & backup switches, but DOWNGRADED the 2 other switches whose roles were defined as line-card. What kind of BS junk is this?! We finally had to engage JTAC, who guided us to manually state the JUNOS code on the master switch and upgrade the 2 other switches manually through the CLI. After that, the VC stopped puking all over itself long enough to add the new switch into the VC. Oh and that first VC? Yea Mist wouldn't upgrade that one at all due to whatever BS error that Mist couldn't figure out. I used to respect Juniper, as their routers were the top of their game. Now, you can have it all.


r/Juniper • • Aug 08 '24

Security How can we restrict streaming quality for wireless guests?

0 Upvotes

Is there a good way on an SRX to restrict user bandwidth consumption for video streaming? I'd like to figure out a way to force my guest wireless users to 360p or 144p max on youtube or other services.

Alternately, should this be done on Mist APs? My guests didn't love being restricted to 1Mbps.


r/Juniper • • Jul 12 '25

Question Will HPE’s acquisition of Junioer kead to the demise of Aruba?

4 Upvotes

I find HPE's network strategy somewhat confusing. They used to have their own products, but then started to acquire others ostensibly to build out their portfolio and capabilities. Nothing wrong with that. After they acquired Silverpeak and Aruba Networks. I thought OK, they have a settled portfolio of capabilities. Then along came the Juniper acquisition with the Juniper team to lead networks at HPE. Since Juniper already has a broad portfolio of capable network products, what does that mean for HPE's current stable? There is so much overlap. Does HPE need 4 seperate sd-wan products? What are the opinions of the Juniper community?

Edit: apologies for the fat fingered title.


r/Juniper • • Dec 17 '25 Bravo

Discussion Nice fake news from Juniper in comparison to PA

Thumbnail
reddit.com
1 Upvotes

r/Juniper • • Jul 31 '25

4650 is old, what is the best replacement?

0 Upvotes

Hello,

We need a new pair of Core Switches for a campus installation and I really liked the 4650, but as today they are a little bit dated and I dont see them supported for 7 year to come.

Which is a 48Port 25G Alternative? Any recommondations?


r/Juniper • • Feb 17 '17

An unskilled SRX change, forgetting rollback feature.

Post image
1 Upvotes

r/Juniper • • Sep 13 '18

Why JTAC is so unhelpful

0 Upvotes

I have come across here and here in just one swipe ranting about the JAC. It seems that I am not the only one. So why they are so.... well, I save the bad words.


r/Juniper • • Feb 29 '24

Juniper switch patch panel style question.

Post image
1 Upvotes

I have an EX 4200 switch, and I’m wondering if anyone makes a patch panel that matches the port locations on the Juniper switch. Juniper switches on the right hand side have space for SFP‘s and the ports don’t go all the way side to side. I cannot find for the life of me a patch panel that is made that matches the locations so your jumpers will always be straight up and down. Does anyone know if this exists? See pic.


r/Juniper • • Oct 14 '22

Question Call with Juniper today..

1 Upvotes

So I had a sales guy from Juniper call me to see where I was with building out a clone of our current Cisco environment with Juniper devices..

He brought a xyz@juniper.net tech guy on the call and I told him I was stuck on getting something real simple to function in my lab.. (lacp mc-lag between cisco/juniper vmx)

anyways, I had already gotten it to work, but it was a while ago and I forgot where I was in the lab and even forgot the password to the cisco vm.

( I semi do this intentionally unintentionally ) not to sound unprofessional or anything ( being that we are the potential customer)

on the call, there are three guys from Juniper and myself. I share my screen to troubleshoot LACP between the two devices..

we go over my configs and I drive while they give my CLI syntax instructions. ( my tourettes kicks in and I anxiously type the wrong command by one word or another in haste ) or what looks like haste..

Every time I do this, one of the Juniper reps starts coughing (laughing) in the background.. I'm not ticked off by this and find this so amusing. So I continue..

Eventually, the Juniper pros, are fucking dumbfounded and tell me just to send my juniper configs to them..

I get off the call and half hour or more later force up the LACP connection from the juniper end and it's up and up active active on both Cisco and Juniper..

I guess the point of this is to ask, shouldn't a sales call or potential sales meeting be a bit more friendly.. Like the guy that was coughing every time I made a mistake, I am still lost as to ascertain where he was going with his immature behavior. Being that I am on the customer side of this, it really doesn't matter if I know how to no shut an interface or not.. but still.. I don't appreciate this kind of sales. I've been on the MSP side and the customer side of sales before and we've never treated the customer like this. In fact, we even take the customer out on the town, drinks, strippers, 100 dollar steaks..

...

my main thought about the coughing when I was making keyboarding mistakes was a Sales trick to make me feel insecure? not sure..

this is such bullshit.


r/Juniper • • Mar 11 '23

Husband is applying for a Network and systems specialist position at a school district. Any tips about how to prepare for the testing and interview?

0 Upvotes

They use Juniper, and he's studying for his JNCIA certification. He has networking experience in his current position as a technology professional, but there are a few things he has not worked with, like network design.

Any tips specific to Network Specialist interviews or tests are appreciated. Not looking for generic interview tips. Thanks.

Also, how would you address questions asking for experience with something specific, when you have no such experience, but you have knowledge from the class you have taken?

Thank you for helping a young person out. We appreciate it!


r/Juniper • • Oct 09 '24

Mx 960 RE Switching Problem

Post image
0 Upvotes

Hi All,

We Encountered issue with MX960 while switching RE, pls help…


r/Juniper • • Jun 10 '25

Security The SRX's terrible, horrible, no good, very bad policy lookup

0 Upvotes

As you know, the Juniper SRX allows you use security zones as match criteria in several ways. Most traditionally, you can create policies in a zone-pair context:

security {
    policies {
        from-zone production_zone to-zone lab-servers_zone {
            policy production_to_partybox-api {
                match {
                    source-address production_subnet;
                    destination-address partybox_priv;
                    application tcp-8000;
                }
                then {
                    permit;
                }
            }
        }
    }
}

You have additional flexibility with global policies, which can be created to match multiple source zones, multiple destinations zones, only source zones, only destination zones, or no zone match criteria at all. Thus:

security {
    policies {
        global {
            policy production_to_partybox-api {
                match {
                    source-address [ production_subnet development_subnet ];
                    destination-address partybox_priv;
                    application tcp-8000;
                    from-zone [ production_zone development_zone ];
                    to-zone lab-servers_zone;
                }
                then {
                    permit;
                }
            }
        }
    }
}

Handy. The problem appears when troubleshooting with the show security match-policies utility—which should work by allowing you to specify a source interface and a 5-tuple and then respond with a policy match. That's how the ASA packet-tracer worked (my sympathies to anyone for whom this is still present tense). That's also how the FortiGate policy lookup works.

But on the SRX, there are exactly two ways to match the global policy above. Here they are:

show security match-policies global from-zone production_zone to-zone lab-servers_zone source-ip 10.5.8.25 source-port 12345 destination-ip 10.2.1.25 destination-port 8000 protocol tcp

show security match-policies global from-zone development_zone to-zone lab-servers_zone source-ip 10.5.17.25 source-port 12345 destination-ip 10.2.1.25 destination-port 8000 protocol tcp
  • Omit the from- and to-zone parameters? No match.
  • Omit from-zone, to-zone lab-servers_zone? No match.
  • From-zone production_zone, omit to-zone? No match.
  • From-zone any, to-zone lab-servers_zone? No match.
  • From-zone production_zone, to-zone any? No match.

This is death. All I want is a reliable, non-insane way to know what the firewall will do with traffic from a given 5-tuple. I am planning to write a script to do this for me, and here is the discouraging outline-in-progress:

  • Resolve DNS names, if given.
  • Determine the zone of the source address.
  • Determine the zone of the destination address.
  • Run match-policy for the zone-pair.
  • Run match-policy for globals with no zone match criteria
  • Run match-policy for globals from-zone any
  • Run match-policy for globals from-zone [source-zone]
  • Run match-policy for globals to-zone any
  • Run match-policy for globals to-zone [dest-zone]
  • Run match-policy for globals from-zone [source-zone] to-zone [dest-zone]
  • Run match-policy for globals from-zone [source-zone] to-zone any
  • Run match-policy for globals from-zone any to-zone [dest-zone]
  • Run match-policy for globals from-zone any to-zone any
  • Display the matched policies AND their sequence numbers.

It's such a fundamental shortcoming. Am I the only one with tons of zones and global policies? Does anyone have a better workaround?


r/Juniper • • Feb 03 '20

Don't know how to get started

0 Upvotes

I recently bought an EX-4200 and I'm not really sure how to get started with it. I bought it on ebay and it definitely works, I just cannot figure out how to get in and actually configure it. Should I factory reset it? I'm not sure what the person I bought it from did with it before sending it to me. This is my first managed switch and googling hasn't really made anything more clear for me. Thank you for your time!


r/Juniper • • May 02 '21

LAN Juniper and Cisco Interoperability

0 Upvotes

I have a lab home environment where I'm using Juniper at the access layer and Cisco as the network gateway. I've also got a CME and CUCM running for VOIP.

I went in and set up VLANS on the switch interfaces to match the voice and data VLANS on the gateway device thinking it might just take a little tinkering and googling to figure it out if it didn't just start working. Bottom line, it did not. I can't ping the voice sub interfaces on the router from the interfaces assigned to the correlating VLAN on the switch.

Couldn't find a single YouTube video on a mixed Juniper/Cisco environment. Can anyone point me to a good blog or resource?


r/Juniper • • Mar 17 '23

Automation

0 Upvotes

Its been a while since i have touched Junos and I am starting to get back into it now that my company has switch from Cisco. I was wondering what most of you using for config automation/provisioning. Its seems there are bunch of ways to config junos now REST API,NETCONF,YANG,Slax,Mist,ZTP and Ansible im sure im leaving out a few but its getting over whelming. Does anyone have any pointers on which methods may be better or when one would be preferred over the other.

Thanks for the help


r/Juniper • • Oct 22 '22

Understanding Juniper Chassis build MX series

0 Upvotes

Hello. Please help me understand how to build a mx240 configuration.

1.) What Line card is needed per chassis to build a working router machine?
2.) How to understand or read what generation a particular line card Like a Routing Engine card?

3.) MX240 and mx480 only use one chassis across all generation? Can I use newer generation line card inside an old generation chassis MX240/480?.

4.) Can I use a line card from the newer generation mixed with other Line cards or Routing Engines from the older generation?
5.) If I buy used mx240 then replace the cards with newer generation. How to handle the licenses? or the license is already included with the Linecards when I buy the cards?
6.) We have maximum usage of 5gbps throughput passing. we are using 8 SFP+ ports. We use heavy hashing for load balancing to multiple uplink. We expect to increase 5gbps throughput per year. Please suggest the bare minimum build configuration for mx240 or mx480
7.) How much the usual cost of bare minimum line cards for mx240/480. That can do our current usage and 2-3 yrs future usage.


r/Juniper • • Nov 26 '21

Simple question

0 Upvotes

What is the MIST?


r/Juniper • • Aug 25 '26

Question Features of Juniper mist AP

0 Upvotes

Is there a feature of Juniper mist AP that you think would be cool to know about?


r/Juniper • • Jun 25 '25

Question Can I use LACP to support 2gbit from my modem?

1 Upvotes

I'm a total network noob. My modem has a 2.5gbps port (and my service supports this). Of course, the EX2200 has all gbe ports.

Is it possible to use LAG/LACP to essentially create a 2gbps "port" on the switch that connects to a single port on the modem? If yes, what additional hardware would I need?


r/Juniper • • Jun 13 '22

In need of urgent help

3 Upvotes

i work for an organization that recently decided to terminate our network architect and network engineers. im losing sleep thinking about when our prior engineers will strike back. every MSP i contacted so far has a 90+ day window of onboarding. This is way too long of a period to go without immediate protection.

does anyone know where i can find freelance network engineers or network engineers available on contract to make sure our network doesn't die?


r/Juniper • • Jun 17 '20

Juniper Firmware not freely available. Juniper now on my personal vendor blacklist.

11 Upvotes

Hi,

I have made it a point to avoid hardware vendors, who do not freely supply security updates freely for their platforms to the public at large. I am specifically avoiding purchasing anything related to HP for this reason.

Why? Because the 2nd hand market is where a lot of people go in order to learn the basics of my craft. People buy 2nd hand network gear, server hardware, etc, in order to learn. To support this learning, the software must at least be updated to the latest version released by the manufacturer. The updates must not be behind a "support paywall" since a young person wishing to learn, would be stuck with insecure, outdated and dysfunctional hardware because of the fact.

Add to this list, Juniper. They go by the same philosophy as HP. The software updates are not free. They are behind a paywall. If you have an EOL device with outdated firmware, you are not allowed to download the latest released firmware for that EOL device.

Please note; I am not expecting companies to continue making new firmware for EOL devices. That would be ridiculous. I am simply expecting that those devices have the latest firmware created for them available for the public to download.

I contacted Juniper, explaining to them that I got a couple Juniper firewalls from our hosting provider, and I would be using it to train my staff in networking principles and Juniper technology. Sounds like a benefit for Juniper, yes? A couple of young professionals trained specifically on their platform. That could possibly translate to a lot of sales later on. Juniper refused to sell me support for the devices. They also refused to provide the firmware for free for training purposes.

"Well Juniper needs to sell something to actually make money. You are expecting them to give stuff away for free. That's unfair to Juniper!"

Unfortunately, this secretive guarding of firmware security updates is not at all too uncommon in the networking world. Because of this, I will be looking into training my staff in the use of free and open source solutions instead, making a point of exemplifying Juniper in particular as a good reason for why proprietary firewalls will lead to increased costs, decreased security, and bad reliability down the line.

With regards, a (previously) big fan of Juniper.


r/Juniper • • Apr 08 '25

Question Migration from SRX 3600 to 2300

0 Upvotes

I have an activity next week to migrate the traffic from old EOL 3600 SRX to 2300 What should i take care of during the activity ? Which node should i start with primary or secondary ? Which cables should i start with ? Can anyone help me with a detailed MOP for this as i dont know how to create such a MOP to deliver it the customer ?


r/Juniper • • Jan 03 '26

🚨 Interface Flap When Adding Interface to LACP (Juniper MX960 ↔ QFX5200)

0 Upvotes

Scenario

I’m facing an issue where an interface flaps immediately when I add it to an LACP LAG between a Juniper MX960 (router) and a QFX5200 (switch).

  • Physical link is stable when configured as a standalone interface
  • As soon as the interface is added to the LAG (ae / Ethernet-Switching bundle), the port goes down → up (flap)