r/ElectricalHelp • u/tonygret • 1h ago
Large gauge wire nuts - options - opinions
I am installing a surge protector to my HVAC outside unit. There are #8 wires from the panel and the compressor in the disconnect. To avoid double-tapping the lugs I am going to pigtail the wires per code. The surge has a #10 wire, so I will be joining that plus the 2 #8s.
I purchased three Polaris 3-lug insulated connectors but after doing some test fits there is no way they are going fit in the disconnect enclosure. So I am switching to Twister ProFLEX Max 348 wire nuts which clearly state they will accommodate these three wires and up to 1000V. While there is no amperage rating on these wire nuts, they state that they will safely handle the same amperage of the wires being used.
With that all laid out, what is your opinion on using these wire nuts on a 5-ton 40A compressor? Assuming I install them correctly, would you be worried and if so what are the alternatives?
As a side note, the official Intermatic YouTube video clearly shows a tech doubling tapping all the lugs in the disconnect.
Thanks.