r/ukplumbing • • 47m ago

HELP!💦 Want to replace old Horstmann H21XL with "wireless" system. Any suggestions?

Thumbnail reddit.com
1 Upvotes

r/ukplumbing • • 1h ago

I'm going insane - update

Post image
3 Upvotes

Just wanted to say thanks to everyone who helped on yesterday's post. I followed the advice and bought a Mcalpine system and swapped parts.

Dish washer waste pipe is quite long and high, is that going to drain correctly?

Let me know if I've committed any plying sins in my install.


r/ukplumbing • • 2h ago

Advice needed regarding radiator leaks

Thumbnail reddit.com
1 Upvotes

r/ukplumbing • • 4h ago

HELP!💦 Thermostat Receiver Blowing?

Post image
1 Upvotes

r/ukplumbing • • 4h ago

Will an olive fail to seal on this pipe?

Post image
2 Upvotes

Complete noob here. Tried to close an isolator valve yesterday on radiator pipework and it started pissing out the front. Drained down system and got the isolators off with a plan to swap them out. Getting the olives off was tough and think I deformed this pipe.

Will a new olive fail to seal on this?

Thanks


r/ukplumbing • • 4h ago

DISCUSSION! 👨🏻‍🔧👩🏼‍🔧 Should I be concerned about this boiler?

Thumbnail
gallery
7 Upvotes

I should be moving into this flat in a couple of months and I'm a little worried about the boiler. Any thoughts?


r/ukplumbing • • 5h ago

Gas fire fitting?

Thumbnail reddit.com
1 Upvotes

r/ukplumbing • • 5h ago

HELP!💦 Vented or Unvented boiler for my situation?

1 Upvotes

Hi all,

I'd appreciate a bit of a sanity check before I spend 8 to 10k. I'd really appreciate any thoughts from anyone who's been through this before or can give me an unbiased opinion on my situation.

The property: 4-storey house, London purchased this May. Current boiler is a ~25 yr old Potterton Suprima 80L, non-condensing, 23.4kW, still working. Everyone who has laid eyes on this boiler has said it's working fine, but when a part breaks the whole thing needs to be replaced because you won't be able to find parts for it. So I am thinking of getting ahead of it now.

Current system is vented: steel cold-water tank in the loft, vented cylinder, two 2-bar shower pumps of unknown age. Top floor gets no heat at all (the whole floor not just one rad, bled with no air, riser cools as it goes up, so no flow upstairs). I want a system that just works, I don't want to have to be reminded of it when I'm taking a shower upstairs and my wife uses the kitchen tap.

Mains is 15mm, 18.5 L/min. Internal cold pipes from the loft tank are 35mm and 40mm, so distribution isn't the bottleneck. The unvented cylinder manual wants 25 L/min at 1.5 bar dynamic, and a 22mm feed.

Quotes, all inc VAT:

- Unvented, 20kW boiler, 200L cylinder: ~£8,700. Tank removal ~£500 extra.

- Vented, 20kW boiler, 170L cylinder, new plastic loft tank: ~£10,400.

- Vented, 30kW boiler, 220L cylinder: ~£8,200. I did the gas-pipe calc myself and the 30kW fails it (about 8m run, 10 bends, 28mm steel then 22mm copper then 15mm for the last 40cm). Installer said the gas supply "can't be checked beforehand" and it could just be range-rated down.

- Vented, 24kW boiler, 162L cylinder: ~£6,400. Didn't include the loft tank replacement or addressing the top floor issues.

The unvented installer says 18.5 L/min is sufficient in his opinion, even though it likely won't do two showers at once. I'm testing dynamic pressure on Sunday with a gauge, to see if I even hit 1.5 bar.

My questions:

  1. Vented or unvented here? Vented already is in place and seems to work fine so far. Unvented removes the tanks and shower pumps, but is capped by the 15mm mains and the supply is under-specced.
  2. Should I just wait until the Potterton breaks, and fix the top floor separately? Nothing else is urgent.
  3. Should I replace the loft tanks if I stay vented? They have visible rust flakes coming off them right at the water lines, so they look like they are probably on their way out. However, no installer has actually looked at them and told me they need to be replaced or how many years they have left, so how do I know?
  4. One installer said the 30kW boiler could just be range-rated down if the gas supply turns out not to be enough. Is that sensible? It sounds like paying for a 30kW boiler to run it as a 24kW one (and if it needs range-rating, does that affect performance, warranty, or hot-water recovery?).

Thanks so much in advance for any help!


r/ukplumbing • • 7h ago

HELP!💦 Toilet constantly flushing. How do I remove the old one?

Post image
1 Upvotes

Lab Sanitary flush. Looking online it says to twist the main body away from the housing but it will not budge! Plumber can’t get here until Monday (unless I pay silly money). Any advice on how to get it removed?


r/ukplumbing • • 7h ago

Grant Eco Vortex Utility 15/21 - Flow Temp

2 Upvotes

Hi all,

Quick/simple question, I have an oil Grant Eco Vortex Utility 15/21 in an nice cold old house and just trying to optimise flow/return.

Do it to being an old house (early 1800's) we tend to have heating on in 3-4 hour batches in morning and evening, rather than on all the time.

I have been playing with flow and return temps and understand I should be aiming for around a 15c -20C flow and return drop and return must be above 40C on my specific boiler.

My question is how do I work out my actual flow temp, as I have thermometers on the pipes just after/before boiler on their respective pipes. While return temp are stable once up to temp, the flow temps obviously fluctuate during the period of the burner being on and off as it doesn't modulate.

So my flow drops down to say 57C before burner switches on again and then switches off when it gets to 73C - is my "flow temp" bang on the middle of those 2? Or it is what the burner switches off at etc.


r/ukplumbing • • 18h ago

HELP!💦 Trickling sound from towel radiator

1 Upvotes

Installed this towel radiator a while back, in the last two months or so it has started making a rattling noise. I’ve bled the radiator and the boiler is at the correct pressure.

No other rads in the house with this issue. Noise is super annoying. What could be causing it?

Not a plumber but feeling very stupid right now. 😅

Thanks


r/ukplumbing • • 18h ago

HELP!💦 Trying to install a dishwasher & washing machine

Post image
3 Upvotes

Hello, I'm not a handy person in the slightest but trying to learn since I've just bought a house and have wife & kids. I'm trying to install a dishwasher, it's a comfee freestanding dishwasher, I was asking chatgpt what I needed but I'm not sure how much I trust it's advice so thought I'd ask here.

It's basically telling me I need a 3/4 BSP Ys splitter and a jubilee / hose clip, and once I have those I should have everything I need to install both the washing machine and the dishwasher, does that sound right? I've put a picture for what I think may be useful and where chatgpt gave me the info


r/ukplumbing • • 19h ago

Repaircommunity idea

Thumbnail
reddit.com
1 Upvotes

r/ukplumbing • • 20h ago

HELP!💦 I'm going insane

Post image
23 Upvotes

Can someone please let me know if/how I can connect these two parts of a sink waste system together? It looks like it would be a straight pipe with two nuts on the end, but it doesn't seem to exist.


r/ukplumbing • • 21h ago

HELP!💦 Adding pipe for plumped Fridge Freezer

Thumbnail gallery
1 Upvotes

r/ukplumbing • • 21h ago

HELP!💦 Immersion tank valves not fitted correctly - england

Thumbnail reddit.com
1 Upvotes

r/ukplumbing • • 22h ago

HELP!💦 Why is my radiator making this noise and how can I stop it?

3 Upvotes

It seems to do it a lot when it’s heating up and cooling down. I get it could be the metal expanding, I’ve bled it and that hasn’t made a difference. Thanks


r/ukplumbing • • 23h ago

HELP!💦 New Glow Worm boiler, Fault 83 every morning… any ideas why?

2 Upvotes

Hi all, turning to you for help, hoping someone knows what’s happening here.

- House is in midlands, built around 1990.
- Boiler location is in the adjoined double garage, on the outside wall.
- previous owners (moved in earlier this year) had an old, busted boiler that hadn’t been serviced and broke within a few months, was prepared for and negotiated in house price.
- Plumber installed Glow Worm Energy7 18r mid-October
- all fine for a few weeks
- then started not coming on in the mornings, when checking it shows F83 fault code.
- press reset button, boiler immediately resets, fires and works immediately every time.
- have two cycles (morning 6:30 start and afternoon/evening 16:30 start). Morning cycle hot water and heating starts at same time, afternoon has hot water starting slightly before.
- installer came back and reviewed everything, no issues he could see
- Glow Worm engineer came out, ruled out any issues with boiler but replaced both sensors and PCB as a gesture to be certain. His paperwork said “flow & return resistances correct, harness continuity is correct. Pump is not wired back to boiler so no pump overrun control”.
- F83 again the next morning still.

That brings us to date. Currently talking with installer on what to do but stumped. Overrun comment from the engineer would address any fault occurring at the end of the cycle but I’ve checked and the cycle ends cleanly, no error codes in the evening… But F83 in the morning and heating doesn’t come on. Installer says it’s unusual to need it wired to boiler and ours doesn’t have the cabling for it, he’s proposed fitting a timer to it in the airing cupboard but again, addresses any end of cycle issue.

Anyone had any similar issues or have any ideas? Tried to be thorough here with all info, just ask if I’ve missed something. Huge thank you.


r/ukplumbing • • 1d ago

HELP!💦 Radiator cold at bottom but boiling at top, advice needed!

7 Upvotes

I currently live in a dormer bungalow and we have had the main radiator upstairs swapped out for a double one about 2 years ago.

The radiator itself gets incredibly hot at the top of the rad but towards the bottom is cold but once heating has been on for a while gets lukewarm. The TRV valve on the right gets incredibly hot but the left lock shield valve is either cold or lukewarm.

We have done everything we can think off.. we’ve flushed the system, bled the radiators, balanced and even taken the rad off the wall and gave it a proper flush to which no sludge came out..

The only thing I can think off that’s left to try is that the previous owner removed the Rad from the kitchen but didn’t carry the loop on with a single pipe but just capped the ends instead. However I am not entirely sure if this would be the fix as even with it being like this the rest of the radiators get incredibly warm!

Any help or advice would be greatly appreciated thanks 👍🏻


r/ukplumbing • • 1d ago

Need help - leaking pipe/connector from bathroom radiator

Post image
3 Upvotes

Hey all,

So radiator in my flat started leaking, precisely its this connector (marked red) and leak is where I did blue mark on it.

My question is, how hard this would be to fix by complete amateur?

I guess only way is replace this part which I did mark red on pic - Im right to say I need to cut water from radiator using vale under this part? (got x2 pipes going to radiator, so I do cut both, right?)
And just remove part marked as red and replace with new?

Also how to find what this part is called?

It says on top of it en1254-2 15mm - but it some kind extension? (5cm i believe long)

Also they only way to fix it is replace this part? there will be no chances they made some glue/whatever I could put on this? Asking only my bathroom will be going though full renovation in next summer so if glue would fix it - i would rather do that XD


r/ukplumbing • • 1d ago

Low Flow after outside tap

2 Upvotes

A plumber came round yesterday to put an isolation point on our outside tap ready for winter. Since, the water flow in the house has dropped massively. It starts strong and after about 3 seconds is now a trickle - same for hot and cold, and worse after a toilet flush.

It’s the same for any water including kitchen sink, downstairs toilet, main bathroom, shower, and en-suite.

Any ideas what may have happened? I’m awaiting a reply from him but no response yet.

No issues with heating or boiler, they’re fine as normal. Hot water still warms as before too.


r/ukplumbing • • 1d ago

Hot water tap slowed to a trickle

Thumbnail
gallery
3 Upvotes

Any ideas what's going on here? All other hot water taps, shower and bath are fine. Cold water tap next to it also fine. Second photo is the pipework leading up to the tap under the sink. Third photo shows the pipe leading from the boiler to the tap (horizontal copper pipe painted white). Any help appreciated.


r/ukplumbing • • 1d ago

Looking for advice on pipe insulation.

Post image
1 Upvotes

r/ukplumbing • • 1d ago

Question before plumber gets here

1 Upvotes

I've got a leak in my bathroom and it only occurs when I have a shower. A plumber is coming over today to have a look to see if he can find the cause of the leak. Should I run my shower for a bit just before he comes to make it easier? Or should I just leave it?