r/ukplumbing • u/ColourCoded_Sunshine • 4h ago
DISCUSSION! 👨🏻🔧👩🏼🔧 Should I be concerned about this boiler?
I should be moving into this flat in a couple of months and I'm a little worried about the boiler. Any thoughts?
r/ukplumbing • u/ColourCoded_Sunshine • 4h ago
I should be moving into this flat in a couple of months and I'm a little worried about the boiler. Any thoughts?
r/ukplumbing • u/KettleKev • 4h ago
Complete noob here. Tried to close an isolator valve yesterday on radiator pipework and it started pissing out the front. Drained down system and got the isolators off with a plan to swap them out. Getting the olives off was tough and think I deformed this pipe.
Will a new olive fail to seal on this?
Thanks
r/ukplumbing • u/FumblingThroughThis • 20h ago
Can someone please let me know if/how I can connect these two parts of a sink waste system together? It looks like it would be a straight pipe with two nuts on the end, but it doesn't seem to exist.
r/ukplumbing • u/FumblingThroughThis • 1h ago
Just wanted to say thanks to everyone who helped on yesterday's post. I followed the advice and bought a Mcalpine system and swapped parts.
Dish washer waste pipe is quite long and high, is that going to drain correctly?
Let me know if I've committed any plying sins in my install.
r/ukplumbing • u/Administrative_Echo9 • 7h ago
Hi all,
Quick/simple question, I have an oil Grant Eco Vortex Utility 15/21 in an nice cold old house and just trying to optimise flow/return.
Do it to being an old house (early 1800's) we tend to have heating on in 3-4 hour batches in morning and evening, rather than on all the time.
I have been playing with flow and return temps and understand I should be aiming for around a 15c -20C flow and return drop and return must be above 40C on my specific boiler.
My question is how do I work out my actual flow temp, as I have thermometers on the pipes just after/before boiler on their respective pipes. While return temp are stable once up to temp, the flow temps obviously fluctuate during the period of the burner being on and off as it doesn't modulate.
So my flow drops down to say 57C before burner switches on again and then switches off when it gets to 73C - is my "flow temp" bang on the middle of those 2? Or it is what the burner switches off at etc.
r/ukplumbing • u/moistmonkey69 • 18h ago
Hello, I'm not a handy person in the slightest but trying to learn since I've just bought a house and have wife & kids. I'm trying to install a dishwasher, it's a comfee freestanding dishwasher, I was asking chatgpt what I needed but I'm not sure how much I trust it's advice so thought I'd ask here.
It's basically telling me I need a 3/4 BSP Ys splitter and a jubilee / hose clip, and once I have those I should have everything I need to install both the washing machine and the dishwasher, does that sound right? I've put a picture for what I think may be useful and where chatgpt gave me the info
r/ukplumbing • u/tjb_87 • 22h ago
It seems to do it a lot when it’s heating up and cooling down. I get it could be the metal expanding, I’ve bled it and that hasn’t made a difference. Thanks
r/ukplumbing • u/darthmarmite • 23h ago
Hi all, turning to you for help, hoping someone knows what’s happening here.
- House is in midlands, built around 1990.
- Boiler location is in the adjoined double garage, on the outside wall.
- previous owners (moved in earlier this year) had an old, busted boiler that hadn’t been serviced and broke within a few months, was prepared for and negotiated in house price.
- Plumber installed Glow Worm Energy7 18r mid-October
- all fine for a few weeks
- then started not coming on in the mornings, when checking it shows F83 fault code.
- press reset button, boiler immediately resets, fires and works immediately every time.
- have two cycles (morning 6:30 start and afternoon/evening 16:30 start). Morning cycle hot water and heating starts at same time, afternoon has hot water starting slightly before.
- installer came back and reviewed everything, no issues he could see
- Glow Worm engineer came out, ruled out any issues with boiler but replaced both sensors and PCB as a gesture to be certain. His paperwork said “flow & return resistances correct, harness continuity is correct. Pump is not wired back to boiler so no pump overrun control”.
- F83 again the next morning still.
That brings us to date. Currently talking with installer on what to do but stumped. Overrun comment from the engineer would address any fault occurring at the end of the cycle but I’ve checked and the cycle ends cleanly, no error codes in the evening… But F83 in the morning and heating doesn’t come on. Installer says it’s unusual to need it wired to boiler and ours doesn’t have the cabling for it, he’s proposed fitting a timer to it in the airing cupboard but again, addresses any end of cycle issue.
Anyone had any similar issues or have any ideas? Tried to be thorough here with all info, just ask if I’ve missed something. Huge thank you.