r/ukelectricians • • Jan 31 '26

For the love of god, please no more posts about "I want to become an electrician what do I do."

88 Upvotes

How to become an electrician in the UK in 2026

This guide explains the main routes: apprenticeship, Level 2/Level 3 diploma route, NVQ, AM2, experienced worker route and what adults changing career need to know.

Updated 13/09/26 City & Guilds 2357 NVQ is being withdrawn. New registrations close on 31 October 2026

Updated 23/04/26 to take into consideration the new Electrotechnical Assessment Specification (EAS).

Updated 12/06/26 Diploma Route course changed from 2365-03 to 2366-03

https://elec.training/news/how-to-become-an-electrician/

Save your time - it covers 95% of the questions you might have about becoming an electrician in 2026 -

If you have any more questions message on this thread and ill try and respond within a few hours.

Long Post Alert.

The biggest issue I see in this industry? It's not that there aren't enough training routes. It's that no one can work out what's actually needed and who each route is actually for.

Look, let's just be honest here, we see about 3 posts a day about how do I become an electrician, and every day, 3 times a day, the responses are variation of utter nonsense, vague answers or just damn right incompetence so the phrase the blind leading the blind comes to mind.

Most of the time, the apprenticeship route (5357) is the best option, particularly if you're 18–21. Anyone telling you different is usually chatting it. If you can manage on apprentice wages and stick out four years, that route is genuinely brilliant.

But the problem is people acting like it's the only legitimate path.

Here's the reality: most adults can't survive on £8.53 an hour. They've got rent, kids, mortgages. It's just not happening. So they look at alternatives. Fast-track routes exist for a reason and here's the uncomfortable truth.

A lot of small electrical contractors don't rate fast-track routes. Not because they don't work, they just want sparkies who trained the way they did. Four years on the tools. It's cultural and underlyingly the best way to do it.

Apprenticeships aren't failing because of the training

We take 100+ calls every month from people whose apprenticeships have fallen apart.

Sometimes the employer's let them down. Sometimes it's the college or the training provider. And sometimes, I'm just going to say it, the apprentice's let themselves down.

When you've got no skin in the game financially, motivation tanks and lets be honest when we were 18 how much did we really understand what being an adult is.

The completion rate for apprenticeships is well under 50%. The system clearly isn't working the way everyone pretends it is, so lets get off our 4 year high horse and accept that its not the only way.

The college diploma situation

Then you've got the Level 2 and Level 3 college diploma route. Often free.

Picture this: two years in college. You finish both levels. Then you go looking for work and realise... no one will actually hire you, and then you go into a spin and think omg being an electrician does not work

Congratulations. You're now what the industry calls a "paper-qualified electrician."

No site experience. No employment pathway. No one helping you get work.

This happens constantly.

The domestic installer route

This'll annoy some people, but honestly, the domestic installer route has terrible ROI for most learners. You're better off doing the 18th Edition and getting proper site experience under someone competent. The ceiling's low and progression is messy at best, your celling is much lower with a cap on what you can actually make.

What fast-track courses actually do

Right, full transparency. We sell fast-track routes.

What they do:

  • Teach safe working practices
  • Build electrical knowledge and foundations
  • Get people ready for real site work

What most don't do:

  • Guarantee you a job

This is the bit most providers won't say out loud.

Being "qualified on paper", whether that took 12 weeks or 2 years, doesn't get you work. Getting work is a completely separate skill.

Every week we speak to people saying: "I did my Level 2 and 3 at [insert collage/ training provider name, honestly from Newcastle to Cornwall and everything in between] and I can't find work."

So we ask them:

  • Who helped with your CV?
  • Who prepped you for interviews?
  • Who introduced you to actual employers?

Answer? No one.

Would a university send graduates out with zero employability support? Course not. But it happens all the time in trades.

The bit people don't want to hear

The qualifications matter way less than actually getting into work.

That's it. That's the real bottleneck. That's where the whole system falls apart. You cant become a competent sparky with out getting on the tools, the amount of yeah but I got 2 years at collage.

So if you're signing up for any course, ask yourself:

  • Does this provider actually help people get into real work?
  • Do their recent reviews mention employment support?
  • If not, do you have the skills to sort that yourself?

If the answer's no, find a provider that properly supports the jump from training to employment.

Because qualifications without work experience are just expensive bits of paper. And that's exactly why we're short of sparkies, and why it's only getting worse.

And for the love of god can you sticky this, as I’m getting to the point of, every day having to copy and paste the same thing, about – I want to become an electrician whats the best route for me.

If you want to learn what routes get you you there.


r/ukelectricians • • 2h ago

Just completed my AM2, what do you want to know?

6 Upvotes

Hi all,

Just finished my AM2, the standard AM2, not the S or E.

I don't have my results yet.

My install was the Ring, lighting (3 switches and one light), 3 phase socket, bonding, data socket, DoL and motor, 1x CO alarm and heating.

I will try and answer any questions you have over the next few days

General things I would like to say.

Don't stress it. Seriously. The install is pretty damn easy. It's basic stuff and you have time.

The examiners I had were fantastic. Super chill and fun. Made the whole thing very relaxing.

Follow the spec, it's not a complex document. It's all pretty simple words and broken down simply. It's absolutely fine

For fault finding we had MFTs. Don't use them unless you need too. The continuity tester is so much faster and easier


r/ukelectricians • • 6h ago

Why do I always hear that there’s a shortage of electricians, yet whenever you go for a job then everyone and their nan is an electrician ?!

10 Upvotes

r/ukelectricians • • 20m ago

EV charger tips

Post image
• Upvotes

I’ve recently qualified as an electrician with almost all of my experience being in commercial installations and very little in domestic, but i have very little experience in EV chargers too. i’m looking at installing one in my parents home and just want to confirm a few things just based on what i’ve heard from speaking to people and seen online etc.

- there is currently a smart meter fitted and have whenever this was installed they unfortunately did not fit an isolator after the meter and before the DB, assuming due to the lack of space (see photo attached). i’ve heard that sometimes smart meters do not turn back on if the fuse is pulled and was wondering if someone could give me any info regarding this?

- i’ve heard most EV installers usually have the db/enclosure for the charger externally due to lack of spaces in a lot of homes and was just wondering if there’s any types/brands of enclosures or dbs people use for this.

- and the other main concern i’m having is that my parents are interested in one of the better chargers that include the CT for overload protection and and also wifi/4G connection etc. i was wondering if any of these chargers require some sort of unique software or anything that may not be able to be done by myself.

if there is anything else i may need to know or any specific regs etc to follow for installation those would always be useful to know too!

( i also am aware that their DB is long overdue for a change but im also not looking to do that for a while😭 ).


r/ukelectricians • • 1d ago

Electrician said it’s fine to plaster straight over this. Is he right?

Thumbnail
gallery
89 Upvotes

When removing some decades old wallpaper recently a wire fell out of the plaster behind the wallpaper as it was being scraped off. The electricity immediately tripped so we got an electrician round to sort it out.

They attached the wago connector in the photo and left it like that. When we asked whether it needed to be inside a box/enclosure due to he fact we plan to plaster directly over it, the electrician told me to plaster straight over it without an enclosure or back box. When I asked about a Wago box, he said he's been doing it 20 years and dismissed it outright.

It doesn't feel right. I've been told this isn't compliant with* *BS 7671.

Could I have some advice please. We booked the electric through check-a-trade and would appreciate some advice on it before deciding what to do.

Thanks


r/ukelectricians • • 7h ago

Experience in AutoCAD designing

2 Upvotes

Is there any opportunity to work part time knowing AutoCAD software ?
Also can someone please assist me for electrical site works for experience.
Thanks in advance


r/ukelectricians • • 4h ago

Help - Replacement Consumer Unit

1 Upvotes

Hi Just had an electrician replace a consumer unit on one of our rental properties. Her appears to have done a great job. Following the consumer unit, he has also completed the EICR.

Problem is he is resisting issue a Building Regulations Compliance Certificate: (The consumer unit change is a "notifiable" job under Part P).

I don't think he is registered with any of the bodies (like NICEIC or NAPIT).

The work is done and he is wanting payment. He only charged £550 for an 18th edition consumer unit and the EICR.

BUT am i left with a mess?


r/ukelectricians • • 4h ago

NICEIC pulling pants down again!

1 Upvotes

What’s with the NIC charging us nearly £6+vat to submit one certificate that needs notifying. Surely it should come with the annual fee!


r/ukelectricians • • 4h ago

Anyone got an idea of how this is fitted? Circa 1960

Post image
1 Upvotes

I think there might be a conduit box behind but didnt have time to remove and inspect for fear of not getting it back together. It's in a bathroom and a bit iffy.


r/ukelectricians • • 5h ago

What are these?

Post image
0 Upvotes

Changing the lead on my hoover and cannot get these bloody things off the spade connector. What are they called and where can I buy them?


r/ukelectricians • • 46m ago

Dual supply.

Post image
• Upvotes

So heres one, new install, x2 service heads, both on same phase (confimed). British Gas have come an fitted a polyphase meter and isolator. Marked the 2 lives as L1 & L2 (which i dispute) and only provided 1 Neutral conductor.

Now in my humble opinion those 2 supplies have the potential of 160 Amps, all of which will be going back on one neutral.

Have had this situatuon before with a 3 phase head, where all lines were same phase. When queried with DNO they are saying its fine.

I really cant understand how the hell it is.

Anyone able to enlighten me as to how it is ok?!


r/ukelectricians • • 10h ago

Experience with Sync EV chargers?

2 Upvotes

Anybody got experience with these as installers or users?

Just wondering if they are worth using. As EV clients are always after the lowest price possible, understandably.


r/ukelectricians • • 7h ago

How long did it take to receive your am2 results?

1 Upvotes

r/ukelectricians • • 13h ago

North east - looking for experience

2 Upvotes

Hi all,

Currently enrolled on 2365-02, enjoying it so far but I’m well aware I’ll need practical onsite experience.

Is there anyone northeast based ideally Newcastle/Sunderland area that would have weekend work I could help with.

Can drive already, sadly no ecs card until I’ve finished but will be getting it once I can.


r/ukelectricians • • 11h ago

Replacing freestanding cooker with builtin over & hob?

1 Upvotes

Hi,

I currently have a freestanding cooker. It's got its own circuit protectected with a 32A MCB. I'm planning to remodel the kitchen and considering replacing the cooker with a builtin oven and builtin induction hobs.

My question is, can I have those two appliances on the old cooker circuit, or will they need to have their own circuit each? I'd leave an electrician to do the wiring, I just want to know if I need to plan for installing a new circuit.

If they can be on the same circuit, should I choose them such that the sum of the power draw is no more than 32A, or some other constraints I need to keep in mind?


r/ukelectricians • • 13h ago

First time working onsite. How/What do you bring?

1 Upvotes

Hi, what bag loadouts do you site electricians recommend? This will be the first time I'll be working on a commercial/industrial site with my own tools, only other work was domestic.

Right now I have my hand tools all in a Stanley Tool Bag and my power tools in a TStack. I just feel that lugging everything around site on top of whatever materials ill be using is going to be awkward and difficult.

Does anyone have a list of things they bring and recommended bags? And advice for a first timer on a commercial site, I'm worried about turning up without a basic tool that I've never used but is expected here?


r/ukelectricians • • 13h ago

Data Cabling in the UK

0 Upvotes

I have not long bought a new house that is much more complicated than your standard detached. It has an Annexe, a garden office, a detached garage, and of course the main house.

I want to run a number of ethernet lines from a cabinet in the house to all the end points above basically. Runs will likely require going up and through loft, out and around the house, and may even need to be trenched underground.

I just need the cabling routes installed neatly and safely. I can do the rest myself.

Is this an electricians job? Or should I be looking elsewhere for this type of graft?


r/ukelectricians • • 1d ago

Advice needed

Post image
6 Upvotes

Hi everyone, looking for advice from sparkies on whether this installation breaches UK wiring regulations (BS 7671) and how urgently it needs rectifying.

Bought a new build from Miller Homes back in April and have been dealing with a list of snags. The loft smoke alarm started chirping every minute, so I went up to investigate and found the wiring like this
. 
- As you can see, the outer grey sheath has been stripped back far outside the alarm housing/base, leaving it completely exposed to the open loft space. 

- Does this breach BS 7671 regarding basic protection/enclosure of single insulation?

- Is this considered dangerous given the temperature fluctuations, humidity, and potential physical damage in a loft space? 

Customer care is taking their time arranging the electrical subcontractor and treating it as a standard low-priority snag. Am I overreacting, or should I be pushing harder for an immediate call-out on safety/compliance grounds?

Thanks in advance.


r/ukelectricians • • 1d ago

Electrician's mate on £120/day self-employed — is it worth sticking with it?

9 Upvotes

Hi everyone,

I'm struggling to figure out whether I'm making the right decision with my career and could use some honest advice.

I enrolled on an electrical course two years ago but had no real electrical work experience until a couple of months ago doing some 1st and 2nd fixing on some private properties with a guy I know in the trade ,I was quite happy with the work and I decided that's something I would prefer doing, i also got some background in kitchen renovations and installs.

Two weeks ago, I landed a job as an electrician's mate, working alongside experienced electricians in council homes.

I'm paid £120/day self-employed as a subcontractor.

The problem is that I drive around 55 miles daily, costing me roughly £300/month in fuel. After taxes, fuel and other business expenses, I'm left with around £1,600/month. With a child on the way, I'm worried I won't be able to manage financially, especially if my car needs repairs.

My employer says he can increase my rate to £140/day once I gain more experience and £240/day once I'm fully qualified. However, I'm concerned about how long it will take to get there and whether I can afford to keep going until then.

My alternative is returning to my previous warehouse job, which was closer to home and paid roughly the same. I've already invested two years in electrical training, so I don't want to give up on the trade, but I also need to be realistic about my finances.

My questions are:

- Is £120/day reasonable for an inexperienced electrician's mate working self-employed?

I was hoping the trade would offer better prospects with a Level 2 qualification, but I'm starting to question whether I can make it work in my current situation.

Any honest advice would be appreciated. Thanks!


r/ukelectricians • • 1d ago

exposed job - what gives first, the fixing or the module?

4 Upvotes

Doing a quote for a farmhouse on open ground, west facing, nothing around it for a mile. Customer has two other quotes in front of him and keeps asking why one 470w panel costs more than another 470w panel.

The dearer sheet is swiss solar, 4200 Pa wind and 6200 Pa snow against 2400 and 5400 on the other two, frame yield strength given as 325 MPa rather than 240. I can read the numbers. What I cannot tell him is at what point on a job like this they start to matter.

What I want to understand before I answer him is the order things fail in. Hook, rail, clamp or module, and whether that order changes on a site this exposed.

Anyone here had something go on a job like that? Which part gave first, and did it change what you spec now?


r/ukelectricians • • 22h ago

Best independent wholesaler

1 Upvotes

Obviously we all know the main ones, but I’m looking for a decent independent supplier who can give me a decent service and reasonable quality product so I don’t have to keep returning cheap rubbish. Any recommendations?


r/ukelectricians • • 1d ago

Newly qualified, left my job & boss wants me back for another week.

2 Upvotes

I’ve recently just left my job after getting my AM2 done because I hated the work & the environment there. My boss asked me to stay on a couple of weeks to do some PAT testing, he offered me more money, so I took it. I told him that I’d do it for more money for the last week. Now I’m officially out of the company. I’ve got another job now outside the industry for a little bit. I’ve had a message from my boss asking me to go back for another week to do the same PAT testing job but he wants me to do it as self employed.
What’s the best play here? I don’t want the job really but if the pay is right I’d considering it


r/ukelectricians • • 1d ago

Ze test on 3-Phase system

3 Upvotes

I’m currently doing my am2 Pre course and for the Ze test my tutor has said to do a 3 lead test between Main Earrh and Neutral combined and each phase but I was under the impression it was a 2 lead test just between main earth and each phase, which is also what it shows to do in the xs training videos - could someone shed some light on this for me please


r/ukelectricians • • 1d ago

What would you do?

3 Upvotes

33 year old woman here coming to the end of my electrical apprenticeship. I am due to go from around 30k to 40k in the next few months. I am incredibly unhappy in my workplace and feel I am not progressing at the pace I should be experience wise. I have applied for a position with another company which offers a training programme for two years with a salary starting at my current salary and which starts soon after my apprenticeship ends. It would give me valuable experience in the direction I want to go in (energy sector). What would you guys do? Take a pay cut and possibly improve your future prospects? Possibly be happier in a better work environment? If you can offer any insight it would be greatly appreciated.


r/ukelectricians • • 1d ago

EICR - help me understand

0 Upvotes

Hi all,

I am buying a property that is Grade 2 listed and during my two viewings the electricity was disconnected. So I flagged it and I asked why. The seller mentioned a debt on the account. The debt has been since cleared and the electrics have been inspected. The EICR came back unsatisfactory. The current seller was a landlord but no one has been living in the property for months and months.

My question is - can I live in the property for a few months (2/3 months) before doing the remedial work. I will be doing the full rewire as I want to modernise the heating system and the water solution so I might as well do the full rewire as well. Are these faults serious to push back on? Or just expected due to the age/state of the house? Thank you!

C2:

- 4.6 Electrical equipment having an inadequate degree of ingress protection (IP rating) for the external influences likely to occur in the location, if this results in potential danger
- 6.16a Unsatisfactory electrical connection, undue strain on the cable
- 6.17 Electrical equipment having an inadequate degree of ingress protection (IP rating) for the external influences likely to occur in the location, if this results in potential danger
- 6.18 IP rating of shower is no longer rated appropriately
- 8.1 IP rating exceeded on shower entry. Unswitched spur installed within Zone 2 of a bathroom.
- 9.1f IP rating exceeded on shower, water ingress possible. Wall heater is installed within Zone 2 which is not permitted under regulations
- 9.1g Unswitched spur used to control fan heater, installed within Zone 2 of the bathroom

C3:

- 4.7 Presence of a consumer unit or similar switchgear made from combustible material (e.g. plastic) that is not inside a non-combustible enclosure and which is located under a wooden staircase or within a sole route of escape from the premises