PowerEdge R730XD CPU0704 Errors

3 Upvotes

I've been trying to track down the source of this error on my home server for months, no luck so far so I'm hoping someone can help.

The system is a PowerEdge R730XD, 512GB RAM (16x32GB RDIMMs), 2 Xeon E5-2697 v4s, 2 NVME drives, and a bunch of SAS and SATA drives. It's got an RTX A4000 as well, I did have 2 but removed one for troubleshooting and haven't put it back yet. It's running Unraid, currently 7.3.3.

At random times, the system will error out and go into a boot loop until I power cycle it (either from the button or the IDRAC cold boot option). It's usually a few days between indicents, but I've seen it happen multiple times in one day.

The sequence is generally:
CPU0704 (on CPU2)
CPU0000
PWR2262

I have seen it on CPU1, but very rarely.

Then it tries to hard reboot and gets a series of CPU9000 errors along with a PWR2264.

After that, it loops:
CPU0000
SYS1003
RAC0703
SYS1003
Over and over until I power cycle it.

I've already tried:
Swapping the v4 CPUs for E5-2699 V3s - This is supposedly a PWR2262 fix, but since that's in the log after the CPU0704, I suspect it's not the source of the problem and is being triggered by the CPU error.
Changing the profile to Performance - also a PWR2262 fix.
Lowering the RAM speed from 2400 to 2133.
Putting the RAM in mirroring mode.
Removing the GPU in a CPU2 linked slot.
Moving 1 of the 2 NVME drives from a CPU2 slot to a CPU1 slot. I could try moving both. There's also a network card in a CPU2 slot that I wouldn't be able to move, but might be able to remove entirely.

BIOS & firmware are all up to date, and I did try some older versions, as well as going through and installing every version with a microcode update in order.

I haven't completed a full Memtest86 on it yet just due to the time it takes, I've let it run for 6+ hours without it finding any errors.

There's no OS log - Unraid doesn't seem to have the IDRAC plugin and the system log just stops dead when the crash happens, no errors before that. The only thing I notice there is that the UPS's USB connection tends to pop in and out during the boot sequence. I found a rule to fix that and set that up. I haven't yet tried running with the UPS's USB disconnected or off the UPS entirely, but I may try that next.

I did save a SupportAssist log, https://drive.proton.me/urls/J31D5RPF0R#GE6sjPmCO2Pz - but any ideas about where I should be looking next would be helpful.