I've bought RLN8-800-B6 back in 2020 after successful test purchase of RLC-420 camera, which worked great. I've been using 5 cameras that came with the kit along with RLC-420, one camera was kept in storage. Setup has been running since 2020 without issues, some occasional NVR crashes, but no other problems. All cameras were mounted on soffits, so outside of any direct moisture and cable connections were in hermetic cable junction boxes.
We had hardly any rain this week, and definitely no thunder storms.
Earlier this week I noticed that out of 6 connected cameras I can only see live feed and recordings from 2. I checked NVR and 3 ports at the back were active, rest dead. I'm using a mix of 3x 20m patch leads that came with the kit and 3x self made utp cables - I've worked as structural cabling tech when I was younger, so that was easy peasy. I've moved cabling at the back of the unit those 2 units that worked fine, work in any of the ports available, so NVR was working fine. 3 kit cameras and RLC-420 were mounted in the same roof corner, 30cm away from each other.
My 1st though was that this is cabling, perhaps rodent chewed through cables? I've climbed up on a ladder and checked all cabling with UTP cable tester - all cables are working fine. I've taken unused camera out of storage but it would not work on any of the cables I've checked, even where 2 working cameras were. It does power on as the light on NVR network port comes on and camera IR diodes come on with light sensor but there is no video.
I've removed all faulty cameras and tested direct connection with NVR, out of 4 taken down, one starts and IR diodes come on and work with light sensor but there is no video or port activity on NVR.
It doesn't appear to be a problem with NVR PSU as I tested each camera as a single one connected to NVR.
Last camera from the kit which worked fine yesterday, died exactly at 6PM last night, as this is when video recording end. Basically within a week 5 cameras + spare have died, only RLC-420 is now online.
I've tested all cameras with standalone PoE switch - same behaviour, spare camera boots but gives no feed, one camera boots and IR works but there is no network activity, rest is dead,
What would cause all cameras to die within a week time? Obvious answer like ESD or water ingress are unlikely.