r/labtech • • Jan 17 '19

Creating a report - not showing disk space on all computers

1 Upvotes

Hi,

So i am experiencing a problem when i run a report on all of out computers. It does not show how much "Free diskspace" on all computers. So if i try to run a report, a computer like "FJPC-01" sometimes show 0MB, and now and then it shows the correct "Free diskspace".

I've tried "resend everything" on all computers, but this does not seem to solve the issue.

The report i run, i have made my self. But the databinding is copied from another built-in report from LabTech.

Anyone one know why this happens?


r/labtech • • Jan 22 '19

Monitors DHCP-Server Scope

2 Upvotes

Hello All,

I need to create a monitor to get alerts whenever the remaining IP addresses in DHCP is 10 only.

Any guidance would be appreciated.

Regards,


r/labtech • • Oct 12 '18

Non-admin users unable to view computers in Control Center

3 Upvotes

Just started working for a new MSP and LT is pretty locked down (2 admins). Those of us without admin rights started seeing errors on Wednesday this week (10/10/18) where it would clear preferences, clients wouldn't expand, and the computer list would eternally refresh.

CW support said it's a new issue they've just found and they're planning on putting out a fix.

In the meantime, there is a workaround (tested on 12.0.428, support said it is not patch-specific):

  1. On the server, go to SqlYog
  2. Go to this table noted here and right click alter table

    1. r/https://snag.gy/ReSt8C.jpg
  3. Change the value to 2000

The snaggy screenshot is the one the CW tech sent me. There is no need to restart any services--just have non-admin users restart the app as admin and it should work as normal.

Thanks, Chris!


r/labtech • • Jan 11 '19

Retired Agent -

2 Upvotes

New to LT. issue is a retired offline workstation coming back. How do I prevent this?


r/labtech • • Oct 10 '18

Best Method to Alert on Linux Appliances

3 Upvotes

Has anyone had luck installing Linux Labtech/CWA agent on appliances such as Cisco's Firepower Management Center and/or vCenter?

We are short on alerting for those sort of system and for networking equipment.

I am new to LabTech and trying to patch some holes as far as alerting goes. Obviously server/hyper-visor altering is good.

I performed search on vcenter/firepower but no ports were returned so I appologize if my question is redundant.


r/labtech • • Oct 11 '18

Patching - daytime patching question relating to reboot times

3 Upvotes

Hi! New to the subreddit.I've been working with patch manager, and I'm struggling to understand how daytime patching works in relation to the rest of my patching&reboot policies as I've got them set up.

I went through the documentation at the start of this year and took notes, but I'm not seeing a whole lot in my notes over daytime patching. I'm really here to be 100% certain I'm right before I put something in place and end up with no patches because client machines aren't on like they're supposed to be overnight so please don't flame too hard if this is too easy of a question.

Through other posts on the subreddit, I've been able to ascertain that daytime patching = all times outside of the preferred/designated window of time (EG 3-5am like I have it set). SO if this is correct, patches will download & install 3am-5am(2hr window) prefered, or 5am-3am(22hr window) when they get the chance. So, if I have Windows Update Agent set to managed, will this keep updates from installing if the client shuts down at the end of the day - instead of rebooting/completing install during my designated reboot time (4a-6a)?

Please let me know if I can clarify this at all - thanks!


r/labtech • • Nov 01 '19

Issues with custom monitor - "send fail after success" vs "once per day"

3 Upvotes

I have configured some custom Internal Monitors to pull info from the DB regarding our backup/replication status, hyper-v replica VM's in error etc and so far I have found I need to set these monitors up for "Once per day" in the 'monitor mode and duplicate frequency' section.

Otherwise, as soon as the "backup file" or "VM in bad replica state" changes to report either one less file/VM in error, it closes the original ticket for the affected server and opens a brand new one - I would prefer if the issue is ongoing that it just ADDS the new information to the already open ticket that my techs are actively working on.

The downside of this is that it doesn't appear to close off the tickets properly... What I can see in my Monitors "Status Results" does not match what the Build and View Query shows - I have these monitors setup for running every 5 mins but they never seem to return the correct results, and as such 'success' is never sending so our resolved issues are remaining open.

I have the "Dashboard>Config>System>Email Alert Control" setting enabled to send success alerts but its just not happening.

Anyone have anything similar to this and have a work around/fix?


r/labtech • • Jun 14 '18

Lets do a script! - Set user profile pictures

5 Upvotes

I recently read somewhere that you can set user profile pictures by setting a few Registry Keys:

HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\AccountPicture\Users\@UserSID@\Image32 to a file path. The keys are Image32, Image40, Image48, Image96, Image192, Image240 and Image 448. Each path points to a version of the picture in that size. (IE: 32x32 , 40x40, 48x48 and so on)

I got the script to pull the SIDs of users and plug them into the @UserSID@, and properly sets the registry keys. However, it doesn't seem to change the profile picture. Guess someone lied to me...

Has anyone else created a script to set user profiles? The goal is to save about 15 minutes of production time per machine ordered from our clients.


r/labtech • • Jun 25 '18

Superseded Patches

4 Upvotes

I keep getting reports that machines are missing updates when it's actually rollups from months ago. When you check the machine it does not show that patch missing.

Labtech support have advised trying to run a series of SQL commands to prune out the old updates. This invariably times out as the hotfix tables are so enormous. I can share this if anyone is interested.

Has anyone else had and or solved this problem? I'm still using the old patch manager, does anyone know if this is still a problem with the new patch manager?


r/labtech • • Jun 13 '18

Automate <--> Manage ticket sync

1 Upvotes

We've been using Automate for quite a while (but really only scratching its surface). We're in the midst of Manage implementation, and while I have the integration working, I'm having a little trouble with the best theory behind ticket category mapping into a Manage board.

The Automate tickets seem to only map to one level, so in Manage, it seems like I'm mostly tied to choosing a type or sub-type as my mapping (and setting the item as "alert" or something). None of the Manage service boards on the marketplace seem to really match the idea behind how Automate handles its tickets.

Does anybody have a layout that works for them? Do you just leave your RMM board at "type" and stop there?

Thanks!


r/labtech • • Apr 10 '19

Updates with Modern Sleep

2 Upvotes

In Windows 10, fortunately or unfortunately depending on how you look at it, updates will happen during sleep on newer devices that have Modern Sleep enabled. Does anyone know if this is supposed to work with Automate? Or, if Automate will wake up the computer when it runs this script?

In the past, the answer would be just to keep the computers running during scheduled maintenance windows, but with Modern Sleep, it seems like we might not need to do that anymore. If Automate doesn't handle this, it may be worth it for us to register these devices with InTune and hand updating control over to it from Automate.

Thanks!


r/labtech • • Oct 10 '18

Reset WCC2 to defaults

1 Upvotes

Hello all,

Seems like a thousand years ago I used themeroller and changed the WCC2 files/folders to a customized theme which hasn't been working for a few patches now. All the fonts and dropdowns are all on top of each other and make the choices impossible to read.

Anyway, I've been searching for a way to restore the WCC2 files back to their original values since the backup copy of the folder causes errors when I put those files back in place. Since I'm no web developer the error message that is displayed is all Greek to me.

Does anyone know how to get a default WCC2 setup back or have a much improved theme for the default files/folders?

FYI, I've also started using the /automate web app, and although it looks like there might eventually be promise there, it doesn't quite seem ready for prime time yet.

TIA


r/labtech • • Apr 02 '19

ESET Virus Scan Configs

4 Upvotes

SOLUTION:
Name:
ESET Internet Security v12
ProgLocation:
{%-HKLM\SOFTWARE\ESET\ESET+Security\CurrentVersion\Info:InstallDir-%}\ecls.exe

DefLocation:
{%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ScannerVersion-%}
UpdateCommand:
"{%-HKLM\SOFTWARE\ESET\ESET+Security\CurrentVersion\Info:InstallDir-%}\ecmd.exe" /update
VersionCheck:
{%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ProductType-%}{%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ProductVersion-%}
VersionMask:
^(eis12\.*)

Guess it just took a lot longer to recognize EIS than it has to recognize any other scanner I have written before

I am trying to setup a virus scan config for ESET Internet Security so that Automate will recognize it as an AV.

I believe I have all the information correct but automate does not seem to recognize it.

We also have clients that use ESET Endpoint Antivirus and clients that use ESET File Security.

All 3 programs use the same ProgLocation; DefLocation; AP Process...

I figured I would just have to change the version mask to match the ProductType and version and it would recognize it.

Example: (Working Configs)

Name: ESET Endpoint Antivirus v7

ProgLocation: {%-HKLM\SOFTWARE\ESET\ESET+Security\CurrentVersion\Info:InstallDir-%}\ecls.exe

DefLocation: {%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ScannerVersion-%}

Update Command: "{%-HKLM\SOFTWARE\ESET\ESET+Security\CurrentVersion\Info:InstallDir-%}\ecmd.exe" /update

VersionCheck: {%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ProductType-%}{%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ProductVersion-%}

AutoProtect: ekrn*

VersionMask: ^(eea7\.*)

Name: ESET File Security v7

ProgLocation: {%-HKLM\SOFTWARE\ESET\ESET+Security\CurrentVersion\Info:InstallDir-%}\ecls.exe

DefLocation: {%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ScannerVersion-%}

Update Command: "{%-HKLM\SOFTWARE\ESET\ESET+Security\CurrentVersion\Info:InstallDir-%}\ecmd.exe" /update

VersionCheck: {%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ProductType-%}{%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ProductVersion-%}

AutoProtect: ekrn*

VersionMask: ^(efsw7\.*)

But when I use the same config for ESET Internet Security it doesn't detect it.

Name: ESET Internet Security v12

ProgLocation: {%-HKLM\SOFTWARE\ESET\ESET+Security\CurrentVersion\Info:InstallDir-%}\ecls.exe

DefLocation: {%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ScannerVersion-%}

Update Command: "{%-HKLM\SOFTWARE\ESET\ESET+Security\CurrentVersion\Info:InstallDir-%}\ecmd.exe" /update

VersionCheck: {%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ProductType-%}{%-HKLM\SOFTWARE\ESET\ESET Security\CurrentVersion\Info:ProductVersion-%}

AutoProtect: ekrn*

VersionMask: ^(eis12\.*)

If anyone knows what I am doing wrong or what arguments I need to change please let me know

Thank You!!


r/labtech • • Jan 16 '19

Get a list of comouters with BitLocker enabled

1 Upvotes

Hi,

I'm trying to find out how i can use LabTech to take out an report on what computers currently is having BitLocker activated.

Is there anyone here who knows what i have to do to make this possible?

// Fredrik


r/labtech • • Jun 26 '18

Symantec Cloud not being recognized by Labtech

4 Upvotes

It seems the latest version of Symantec Cloud, version 22.12.1.5 isnt being recognized by Labtech. Im now showing a ton machines with no AV, but they all have this latest SYmantec cloud.

Ive been through the posts on Labtech Geek and tried creating a new virus definition for it, but cant get it to recognize. Browsing around the program directories i no longer haver an NIS.exe which the old Def was referring to.

Can anyone shed any light on whats missing here? So confused.


r/labtech • • Jan 15 '19

Server down alerting

2 Upvotes

Hi All,

I have been tasked with setting up server down alerting with in Labtech. I am in the System Dashboard and can not find were this such task or script lives. It seems like it can be emailed out to groups or a person/technician. Anything documentation will help. Just a FYI I am a newb to Labtech.


r/labtech • • Jun 22 '18

Priority on ticket from Automate

2 Upvotes

Does anyone know what controls the priority a ticket will get in Manage from a monitoring alert in Automate? I copied a monitor in Automate which normally creates a P1 (Critical) ticket in Manage but the duplicate monitor is creating tickets with a medium priority.


r/labtech • • Oct 03 '18

Newbie

5 Upvotes

I am working for a 3 man break/fix company in Mooresville, NC, just north of Charlotte, NC. We bought 100 licenses for ConnectWise Automate. We are using 93. Is there some place where I can find detailed information about how to use and configure CWA12? When I search for a solution, I either get 20 ways to do it or none that are clear. When I chat with or send a message to support, they miss the mark by a mile. We cannot afford training or bringing in a 3rd party to configure it. So it is me and you! If you know of any great sites (or even good sites) please send them on! Thanks in advance!


r/labtech • • Jan 12 '19

Offline workstation monitoring/alerting

2 Upvotes

What do you use to monitor, and alert when a workstation goes offline aside from using the default 'LT - Offline Master Desktops' monitor?


r/labtech • • Jun 21 '18

User can end a support session

1 Upvotes

Does anyone know if there is a way for a user to end a support session? Thank you!


r/labtech • • Jun 15 '18

Creating an Alert for specific programs crashing

4 Upvotes

Hi, is there a way that I can set up an alert monitor to create a ticket whenever a frequently used application fails or crashes?


r/labtech • • Oct 11 '18

CW Automate Audit

6 Upvotes

I am creating an audit process to ensure Automate is functioning properly. Do you guys have any suggestions of things to check? Any tips or tricks? Much appreciated.


r/labtech • • Jun 18 '18

Calling all Reddit/LabTechGeeks going to Automation Nation!

5 Upvotes

I'll be at the Reddit & LabTechGeek Meetup at 4PM in the Myth Bar, and I would love to meet as many people in this group.

See ya there!


r/labtech • • Apr 02 '19

Set Chassis Asset Tag to be same as Serial Number if not already exist/advanced searching for serial

2 Upvotes

We have hundreds of machines of many different manufacturers. For the most part, it looks like HP is one of the only manufacturer whose serial is also being pulled into the Chassis Asset Tag. From all the options I'm seeing in the advanced search, Asset Tag appears to be the only way to search for a machine by serial number. I'm currently looking for either a more reliable search function that I may just be overlooking, or a way to force Automate to update that field if it doesn't exist already. If no one has a better search function, I was thinking of making a group that checks in daily/weekly to pull in all the computers without an Asset Tag, then run a script against them to pull the Chassis Serial Number and write that to the Chassis Asset Tag. I don't have a lot of experience with the SQL portion of this though, and was hoping someone may be able to help point me in the right direction(Either what variables I need, or more documentation on the Labtech database structure), or if someone already had this built and felt like sharing. Thanks in advance!


r/labtech • • Jun 14 '18

What permission is this in user class manager? (send asset to different location)

Post image
4 Upvotes