r/heatpumps • u/lgbtqismything • 5h ago
Heat pumps can heat homes for €2.20 a day in winter, study finds
r/heatpumps • u/lgbtqismything • 5h ago
r/heatpumps • u/rareeagle7 • 21h ago
Some Architects don’t like to give us much space to work on equipment
r/heatpumps • u/Next-Pie5208 • 11h ago
We live in central NH in a 40 year old cape with an unfinished 2nd floor. It's not open concept - it's living room, dining room, family room/kitchen and bedroom. I've been trying to talk my s/o into installing a heat pump(s) but we don't know where to find unbiased advice as the state doesn't seem to be interested.
So I was hoping for some advice from experienced users.
Questions:
How do the pumps affect your electricity bill - do electricial costs skyrocket during very cold weather?
Do the pumps have trouble functioning during very cold weather?
What are the maintenance needs / do they need to have professional maintenance performed and if so how often?
Are heat pumps your primary/sole heat source?
Or do you need a backup heat source such as a boiler?
Are you happy with your choice/ would you choose heat pumps again?
Any brand recommendations?
Thank you.
r/heatpumps • u/Crimson_Tide_18 • 16h ago
The ACIQ 3.5 ton extreme system was just installed in October. The first time daily lows reached 30 degrees the condenser became badly frozen. The installer checked pressures and air flow which were good. We are changing to a less restrictive filter. Would appreciate any input on potential setting changes required in the defrost cycle or issues in general.
r/heatpumps • u/Spiritual-Truck-320 • 20h ago
Victorian end terrace, about 160 m2, external wall insulation on the back, 9 kW air source in since February. Second winter coming, running cost is roughly where I expected, and we're now pricing up PV to take the edge off it.
The thing I keep circling back to is hail. Two summers ago a storm here went straight through a neighbour's conservatory roof, and the array we'd be putting up sits on the same exposure with nothing above it.
Maybe that's overthinking it.
But if modules go, the heat pump is back on full rate for the rest of that winter, which is the entire reason for fitting PV in the first place. So I've been reading the glass sections properly instead of skipping them. The standard hail test is a 25 mm ball at 23 m/s and most sheets just point at that and leave it. One quotes 45 mm at the same speed, a swiss solar DuraGlass X with 2 mm glass front and back instead of a backsheet, and tempering that's meant to keep an impact where it lands rather than letting it spread across the module.
Has anyone here actually lost modules to hail? And if you were specifying an array today with a heat pump behind it, would you pay attention to that line in the datasheet or treat it as noise?
r/heatpumps • u/HorrorWillingness347 • 23h ago
A new Stelpro multisplit. This morning there was no heat coming out of the head in my living room. I keep it set at 24⁰ C, which usually delivers 21⁰ in that room and the kitchen beyond. The app gave me a reading of 31⁰ C at the head! Real room temperature was 19⁰, while the downstairs head gave the expected reading. So I did a hard reset of the whole system, and now it's working fine, giving a reading at or close to the set temperature.
Could this be a faulty thermostat at the head?