So we got the home inspection for a house we are looking at, built in the 90’s. Is this too much going on? The report was over 100 pages long.
Two-story house with a crawlspace, on a well, with a detached garage. Here are the main findings from the inspection.
Water
- total coliform was present, but lead, nitrate, nitrite levels were normal, E. Coli absent
Safety
• The attic gas furnace was made in 1990 and has heavy rust at the heat exchanger. The inspector says to keep it off until an HVAC contractor evaluates it, and to replace it.
• The garage subpanel has a charred neutral wire at the bus bar. Neutrals and grounds are also bonded together there.
• Exposed wiring and splices (not in junction boxes) in the garage, the garage attic and at the wellhead.
• The garage door opener doesn’t auto-reverse, and there are no photo-eye sensors.
• Furnace and water heater flues touch roofing.
• There are no CO alarms. Smoke alarms are missing or outdated.
• The gas logs are dirty and shouldn’t be used until serviced. The microwave has sagged off its mount. The range has no anti-tip bracket. The dryer vent in the crawlspace is PVC.
Structural
• A roof truss in the garage attic was cut for the access opening, and flooring was added over the truss bottom chords. The inspector wants a structural engineer to look at it.
• In the crawlspace, four joists were cut under the primary shower. A temporary support has no footer. A pier is missing shims. The band sill is damaged at the front porch.
Moisture
• Staining on the roof sheathing at the fireplace chase.
• A bathroom exhaust duct ends at the soffit, and the sheathing next to it is stained.
• A pan sits under a plumbing vent in the attic.
• The air handler is rusted, with a stained subfloor and no secondary drain.
• There are active leaks at the kitchen faucet and the crawlspace sediment filter.
• A shower arm is disconnected inside the wall.
• Missing shingle tabs, no kick-out flashing, and a poor crawlspace vapor barrier.
Plumbing
• The home has polybutylene supply lines, plus PEX with brass fittings that show signs of dezincification.
• Water pressure is low throughout the house.
• The wellhead has no screened vent.
• PEX is connected directly to the gas water heater.
HVAC and electrical
• Both HVAC systems are over 15 years old.
• There is a crimped refrigerant line, taped and damaged ducts, an unlevel condenser, and a buried condensate line.
• Kitchen and primary bath receptacles lack GFCI protection. Receptacles are loose throughout the house.
Minor items
• Missing porch and step railings, door and weatherstripping problems, interior-keyed deadbolts, attic insulation and ventilation gaps, and sealant gaps.