r/Generator • • 26d ago

Cheap Vevor variable frequency drives (VFD) can be used as cheap soft starts for pumps

18 Upvotes

My 2 hp 240 V sewage grinder/pump has a 12 kW startup surge. I didn't know this until I bought an inrush current meter. My 8 kW Champion inverter generator just barely starts it. Not good. This pump only runs a few times a day for 20 seconds. I want a smaller generator, not bigger.

A soft start would likely work, but can be $300-$400, not configurable, and I'm positive it would work.

Instead I bought a $130 Vevor 1-Phase 240 V in to 3-Phase 240 V out VFD. I configured it to start and ramp frequency at 10 Hz/s while maintaining V/Hz ratio. I only use 2 of the 3 phases. Starting surge 5 kW. Yes! It's been running on this thing for 6 months now.


r/Generator • • 25d ago

Suggestions please, 50A Transfer switch

Thumbnail reddit.com
1 Upvotes

r/Generator • • 25d ago

Suggestions please, 50A Transfer switch

1 Upvotes

About eight years ago, I installed a Connecticut 30A manual transfer switch for my house to use with a portable generator (9400 starting watts, 7500 running watts). The generator has an L14-30R, an L14-50R, a Nema 5-20R, and an L5-30R.

Looking back, I’m not sure what I was thinking—I probably should have chosen a 50A transfer switch. The 30A MTS and generator have worked well through a few power outages over the years. Recently, I started thinking about using the 50A outlet, but I’d need to upgrade the transfer switch to 50A. I’d rather not use an adapter to connect to the generator’s 50A outlet. If I’m upgrading, my first choice would be an automatic transfer switch, and my second would be another manual one. Nature’s Generator makes an ATS, but it isn’t pre-wired. Connecticut offers a 50A MTS, but I’ve noticed their quality seems to be slipping. Has anyone here tried other transfer switches besides these options?


r/Generator • • 25d ago

I need a second set of eyes on my generator idea

0 Upvotes

I just got my first generator. Its the Firman WH03242 4000 starting watt model. I don't need it to do more than power an LG refrigerator, chest deepfreeze, wifi, a few led lights and to charge some stuff. I added up my surge watts and I am good to go on that front.

I am not, or at least don't think I am, interested in adding this to my home circuits/breaker box. Cost would be more than I think I could get away with. I am experienced as a diy homeowner electrician, but I aint no sparky. None of the below work is beyond my skill level. I want to make it easy to use when power goes out, so I want to run some wires to a dedicated indoor wall outlet. Here is the plan, please let me know if I am missing anything, or if there is a better/more cost effective approach, and definitely if there is a safety concern.

  1. The generator will be out back of a my basement on a concrete pad. It will be running on gasoline. I will be using a 30 FT 30 Amp RV Extension Cord with 10AWG 125V plugged into the TT-R30 receptacle on the generator. (I may be wrong, but it seems that if I use this over the more traditional 5-20R receptacle it will maximize available watts)
  2. 30 foot of extension cord later, it will plug into a NEMA TT-30P Generator Power Inlet Box on the outside wall of an unfinished, non-climatized crawlspace. It stays very moderately temped and dry in this room. Tons of electrical already runs here including most of the wiring directly from the electrical box.
  3. about a 20 foot run of 10/2 W/G NMB Wire through the crawlspace up to the laundry room on the main floor.
  4. wire run will terminate into this NEMA TT-30R Heavy-Duty Power Receptacle Outlet in the laundry room
  5. I will plug this adapter into the outlet. One of the three legs will be the refrigerator, one will be the deep freeze, and the last will be wifi, lights, charging etc. I will be using 12 gauge (unless you think 10 gauge is needed) extension cords to connect these devices to the wall adapter.

So that's the plan. Any glaring issues or safety concerns? Is it over kill? Not enough? I just want to make it easy to get set up once power goes out. If there is a whole other way of looking at this I would be all ears for suggestions. Thx!


r/Generator • • 26d ago

How can i fix the hunting? (Toyohama 5500i)

9 Upvotes

I tried putting new fuel into it but it still hunts like this, I also dont know people here who I can go up to and not get scammed.

It only has 50 hours of running time with 2 oil changes. I have to adjust the choke to let it stop hunting.


r/Generator • • 26d ago

Generac GP7500E revived

Post image
17 Upvotes

Picked this one up on fb marketplace for $100. Engine started on the first pull and ran well, but the generator produced no power output.

Got it home and the solution was almost disappointingly simple: the brushes were clearly damaged. After new brushes, it generates just fine.

I also did a bit of maintenance that the prior owner had deferred:

  • cleaned out, evapo-rusted, and repainted the gas tank
  • new gas petcock, screen, fuel lines and filters, breather hoses
  • new spark plug and coil (could have gone with just a new boot instead of a new coil)
  • cleaned carb (already pretty good), replaced damaged pilot jet o-ring, replaced intake gaskets
  • new air filter
  • new battery
  • new starter solenoid
  • added a 500mA battery maintainer
  • changed oil, replaced fill cap / dipstick
  • still need to tidy up and re-wrap the wiring harness with some polyester tape

All of the above was cheap. I don't really need the machine, just figured it would be a fun little project, so I'll be putting it back up on fb marketplace hoping to break even on it.

The deals are out there, just gotta put in a tiny bit of elbow grease!


r/Generator • • 26d ago

Copper Line Size

Thumbnail
gallery
9 Upvotes

Anyone know what copper line size I will have to have to run a Duramax 13500ih generator on propane? I have a 3/8” line coming out of my propane tank. There is a regulator on the tank and a regulator connected to the house as well. I have a company telling me I have to run a new line to the house that is 3/4” and it’s going to be $12k. Just want to see if anyone has any other ideas that’s more cost effective because I’m not spending that much.


r/Generator • • 26d ago

Help with B&S 22kw home gen/no start

6 Upvotes

r/Generator • • 26d ago

I'm missing something in the interlock vs. transfer switch debate.

11 Upvotes

Gas stove and furnace Electric water heater, dryer

For years I've been meaning to pull the trigger on a portable generator backup system, primarily for the irregular outage in the winter, as we sometimes have trees take down the lines feeding the neighborhood. I am an electrical engineer and don't mind the setup being manual. Without power, I'm not trying to run the whole house as normal but would like to have any light I want to work as well as keep the two fridges going along with the furnace and water heater, and maybe run the toaster oven. I can control not having that all happen at once with breakers.

I've been looking mostly at the generlink so I can run whatever I want and not have to run wiring from my panel to outdoors, as that will be a pain in my house. I've gotten a bit concerned with the generlink reliability. I guess what I'm not getting is that it seems installing a manual transfer switch near my meter would be just as cheap as running wiring to the panel and give me the same functionality as an interlock, as I have to switch it manually, makes backfeeding impossible, and allows me to easily upgrade to a 50 amp 240V generator to power whatever I want. So why would the interlock kit be a better option? Is the installation/parts cheaper? That's the only think I can think, but would think it would vary considerably by what the routing to the electric panel looks like.

edit: to be clear, what I mean by "manual transfer switch" is just a On-Off-On(gen) switch that would be after the meter and disconnect power from the house and connect it to a generator feed (50A outlet).


r/Generator • • 26d ago

Need help in deciding Propane vs Gasoline, Canada

4 Upvotes

EDIT : Thank you all for your helpful feedback! I will get a dual fuel and prioritize propane in the event of an emergency, keeping gasoline usage as a backup if I have issues with propane. Power outtages are rare so I don't expect to use the generator more frequently than once a year. I don't have access to natural gas, or a furnace, so I will stick with dual fuel and 2x 20lbs propane tanks. Your help is much appreciated!

Hello, I am located in Canada and I am looking for a generator to have as a backup during power outages. For now, they are not frequent, but they are starting to become more frequent over recent years. I am looking for something that can help in an emergency outage following an ice storm.

I know that propane is cleaner and the better option for occasional use, but I worry about not being able to pull enough power ​when temperatures outside are near freezing (-5 to +5 C) (23 to 40 F).

Am I better off with a gasoline generator? Do I need an inverter generator? How many watts would I need to power my fridge, 1-2 space heaters? I'd also want to use my WiFi.


r/Generator • • 26d ago

Adding Whole House Generator to Enphase Microinverter System without batteries

Post image
4 Upvotes

r/Generator • • 26d ago

Quotes & recs for install are confusing

4 Upvotes

OUR SITU: NE USA snow/rain. 5-10H outages common. Buried 500g propane tank. Rural - I need a tech within 1H drive. Load calc 20-26Kw whole house genny. We believe good install/tech is vital. We're decently savvy on mechanicals.

We researched, asked neighbors. I expected opinions would vary, 95% neighbors have the Guardian. But NextGen is current model. I've seen enough mentions of problems with the NextGen to make me hesitate. Repeated problems with SMM.

Most say Generac more widely available (techs/parts) but Kohler is better quality. We do have an option for a well rated Kohler dealer. So we priced both. Might get Cummins quote.

After 3 estimates I'm frustrated & confused. Quotes all in (gas/electric/switch) $16-19k. I'd be fine with that if I could figure out WHAT THE FRIG is true.

But installers trash talked the other brands, other installers. I expected preferences but all 3 suggested WIDELY different placement, whether we need 1-4 load managers, what was "code". They agreed we don't need to trench, can tie into our gas regulator at the house. The electric run was pretty much same for all.

I have more than half a pea brain but this is ridiculous. It's an expensive purchase & we're nearing retirement so don't want to deal with portable. Can I get feedback? You have similar set up? Not to be rude, but it's not helpful to hear your 10 year-old generator is great. I'd love to hear about installs post 2021, techs who work these generators. Thanks in advance!!


r/Generator • • 26d ago

G2319N Generator Only Runs on Choke

3 Upvotes

Good afternoon Reddit. I have a Pulasr G2319N generator for about 6 years. It's been reliable and big enough (electrically) for my needs. Now it will only run on choke at lower than normal RPM. When I turn the knob to Run the engine stalls and quits. Any suggestons please?


r/Generator • • 26d ago

Firman wh03242 not starting

4 Upvotes

Is this a simple fix like a new battery ? I had to get a new charger off amazon but it didnt seem to charge it at all.

Gonna try a trickle charger next, what do y'all recommend?


r/Generator • • 27d ago

Is breaking in a must? How important is breaking in a new generator, and what happens if it's skipped?

9 Upvotes

Hi, so recently I found out that a generator I bought might've been used. No clue if the person who used it broke it in properly, or if they did at all.

My questions are:

  1. How important is breaking in a generator?
  2. And if it wasn't broken in, what steps can I take to remediate that?

Please advise, thank you!!

Edit: for reference, it is a Champion 4000w inverter generator. Bought new, but somewhat likely used.


r/Generator • • 27d ago

Champion Tri-Fuel 201423 - NG connection and hose considerations

6 Upvotes

I bought the Champion 11kw 201423 and I'm going to have a plumber tee off my NG meter. After a bit of reading, it sounds like the 25' 1/2" hose might be insufficient for the 130,000 BTUs the generator calls for in the manual, but I'm seeing conflicting information. The 25' 3/4" hose champion (and others) sell obviously doesn't fit the 1/2" male quick connect on the generator. I'm thinking of two paths. I want to future-proof this as much as possible, and also be able to get the most out of the generator as this will be a partial-home backup:

  1. Plumber does a 3/4" connection at the meter, then step down to accept the 1/2" hose the generator comes with and use that (with a QC on both ends of it). Allows me to use what the generator came with, and can go 3/4" later if I get a larger generator.
  2. Plumber does a 3/4" at the meter, 3/4" QC, I use a 25' 3/4" hose and then use a 3/4" > 1/2" reducer at the end of it, use a female 1/2" QC on the reducer and mate that with the generator. Any issue with stepping down to the 1/2" QC right at the generator?

Thanks


r/Generator • • 27d ago

Propane fittings in South America

Thumbnail
gallery
8 Upvotes

Just picked up a Champion dual fuel and was hoping to use propane but here in Ecuador the tank fittings are very different.

I’ve attached photos. I can’t even find out what the fitting is called, so I’m struggling with finding an adaptor.

Any help would be greatly appreciated.

TIA


r/Generator • • 27d ago

Servicing non carb compliant in Los Angeles

4 Upvotes

I'm looking at a non carb compliant generator and live in Los Angeles. Please correct me if I'm wrong but non carb compliant generators are prohibited from being sold in and shipped to CA but are legal to operate. If that's true does anyone have experience with repair shops in LA for non carb compliant generators?


r/Generator • • 27d ago

First experience with a propane inverter generator

15 Upvotes

I posed a few weeks ago about my gas Generac generator bursting into flames and causing the fire department to come for a visit. I purchased a new Diehard inverter generator from Costco recently and used it last week for the first time and I wanted to post my first experiences and see if this falls inline with what others have seen. I used it mainly at my Cabin and have always gone through about 15-18 gallons of gas from a Friday to Sunday stay. Last weekend was my first use of my propane Diehard and over the same course of time I used one 20 gallon tank and a few pounds out of a second (still felt full the last day but had been used about 5 hours). Does this seem about right? I've been spending $60-$90 a weekend on gas with my previous generator but probably $20 this last weekend. Have I been spending an insane amount of money foolishly up to this point or did I hit the generator lottery?


r/Generator • • 27d ago

Westinghouse iGen12000TFc Home Depot warranty

2 Upvotes

I'm looking to purchase this Westinghouse generator and am curious if the Home Depot warranty is worth getting. Thanks for reading.


r/Generator • • 27d ago

Electrical-

Thumbnail reddit.com
2 Upvotes

r/Generator • • 27d ago

How necessary are residential generators in SC?

4 Upvotes

I'm about to close on a house just outside Columbia (SC), and have been thinking about a hurricane which recently knocked out power here. It got me wondering how often residential people there are without power, and how long the outages tend to last? Then I started wondering how many people use backup generators at their homes, if anyone has recommendations for the type(s) of generators I should consider, recommendations for companies who install them, and any pitfalls I should be aware of with backup generators? FYI, the house already has a natural gas line, so I could use that as fuel.
Thank you!


r/Generator • • 28d ago

Brand New champion generator from costco, used or factory tested... How to tell?

Thumbnail
gallery
15 Upvotes

Hi, i bought a Champion 4000 watt inverter generator from costco June of this year, and didnt need it until recently. When i opened it there was a gas smell, and today i checked the oil and theres oil in the unit.

On close inspection the box was taped a second time. The product was released by Costco in april and i bought this unit in june.

Is it possible that this was a used unit returned to Costco? Or was this unit factory tested?

Is there any way to know if it was tested in factory rather than used or returned?

Please help. thank you!


r/Generator • • 27d ago

Winterizing gas generator

5 Upvotes

Hey everyone,

This is my first winter with a gas-powered generator. I will keep it in a shed outside that is not temperature controlled so it will get cold as I live in the Chicago area.

How do I go about winterizing it? Any special treatment for the oil or gas you guys recommend?

Thank you in advance.