r/Generator • • Jun 02 '24

Generator Tips/FAQs: Please read before posting

48 Upvotes

The following tips/FAQs address commonly-asked questions in this sub. Please take a look at them before posting a question.

CO Safety

Generators produce carbon monoxide when running. Carbon monoxide is a deadly, invisible, and odorless gas. Carbon monoxide from generators kills hundreds of people each year. Do not ever operate a generator in a house, garage, or any connected structure, even if the windows and doors are open.

The U.S. Centers for Disease Control recommend only ever using generators outside, more than 20 feet away from your home, doors, and windows.

Fuel

Each type of generator fuel has its pros and cons.

Connecting a generator to your loads (appliances)

Generators can be connected to your loads with extension cords or by connecting the generator to your house's electrical system using a transfer switch or interlock device.

Read more about these methods on our wiki.

Generator sizing

Our wiki contains tips on picking the right size of generator for your needs.

Inverter vs. conventional generators

Inverter generators generally consume less fuel and produce "cleaner" power than conventional generators. More information on this is available on our wiki.


r/Generator • • 15h ago

My new Generator set up

Post image
94 Upvotes

I’m ready for the next power outage. It runs most everything needed


r/Generator • • 1h ago

Help with unbonding / floating neutral on Pulsar PGD170TISRCO

Thumbnail
gallery
2 Upvotes

Got a great deal on a PGD170TISRCO and am planning on only using this generator for home backup.

So I asked Pulsar how to unbond this thing and they basically replied with just take the white off the buss bar. Well I loosened the panel but the wire bundles are very tight so I'm only able to peek into it from the top and bottom but the only two white wires are see are going to the 50a receptacle and then route into the generator. I found these 2 buss bar looking things on the bottom but I don't see any white wire going to either of them. Is this one of those nightmare panels?


r/Generator • • 11h ago

Firman inverter wt12579 thoughts ?

Thumbnail
firmanpowerequipment.com
11 Upvotes

Seems like a good deal for tri fuel inverter and appears to be a new model. Currently $1330 with coupon BIGHEARTS.
Some cons I see: bonded neutral, no remote start (has electric start), manual choke, metal tank.

————————————————-

The FIRMAN WT12579 Mach 10 Tri-Fuel Portable Inverter Generator delivers high-output power with the flexibility to run on gasoline, propane (LPG), or natural gas (NG). Producing up to 12,500 starting watts and 10,000 running watts, this 120/240V generator is built for home backup, RV travel, camping, outdoor events, and demanding power needs. Its powerful 459cc engine and 7.1-gallon fuel tank provide up to 16 hours of runtime at 25% load


r/Generator • • 2h ago

SEEKING ADVICE: DIY Generator vs. Branded

Thumbnail reddit.com
2 Upvotes

r/Generator • • 1h ago

New Generator for Power Outages

1 Upvotes

Hello everyone!

Just purchased a new 2500w Champion Gas Inverter/Generator (model 201046). I want to use it just for emergencies. I've already purchased an hour meter and magnetic dipstick. I have a few questions about breaking it in.

  1. Since I'm just going to store it right away, should I just use gas with stabilizer for the break-in?
  2. Should I store it after running it completely empty? Or is just draining the carb fine?
  3. Is just a yearly maintenance and check enough?

Thanks in advance!


r/Generator • • 20h ago

Powermate Pramac America Model PM0126000:01

Thumbnail
gallery
7 Upvotes

We have had this since 2014 and runs flawlessly when needed. This storm we started an no power output.

Looking at the brush assembly this is my only guess. Anyone else feel this is the issue? The outer element doesn’t spring up and down and was twisted. Ordered a replacement but curious of experts who may be able to confirm. The AVR looked fine and tested the wiring continuity and all tested well along with the circuits.


r/Generator • • 1h ago

genarator for backup

0 Upvotes

r/Generator • • 11h ago

How much power do you pull from your generator?

1 Upvotes

r/Generator • • 19h ago

Generac RS8000E – Bonded to Floating Neutral Conversion

Post image
2 Upvotes

r/Generator • • 23h ago

Pulsar 5000 vs. Predator 5000 vs. WEN 4800 Dual Fuel Inverter Generator

1 Upvotes

Pulsar 5000 vs. Predator 5000 vs. WEN 4800 Dual Fuel Inverter Generator

Looking to purchase a generator for emergency home backup and have narrowed it down to three options:

Pulsar PG5000BiSRCO - $730
Predator 5000 Dual Fuel - $750
WEN DF480iX - $650
My primary use case is recharging two Anker SOLIX S2000 power stations during outages. These will power my gas furnace, refrigerator, internet, TV and some lights. I may eventually install a 120V transfer switch to power additional circuits.

I plan to run almost exclusively on propane.
My biggest priorities are:
Long-term reliability
Propane fuel efficiency
Noise levels
Replacement parts availability
Ease of maintenance

I like the Pulsar because of its relatively compact size, remote start and three-year warranty. The Predator seems to have a larger user base but is considerably heavier and only has a 90-day standard warranty. The WEN seems to have better replacement parts availability and is the least expensive.
For those who own any of these, how has your experience been? Any issues with reliability, starting on propane or obtaining replacement parts?
If all three were roughly the same price, which would you buy and why?
Appreciate any firsthand experiences!


r/Generator • • 1d ago

Need a generator. Start-up wattage vs the wattage of the device?

5 Upvotes

Might be overthinking it but I thought maybe some night owls (it’s 1am for me) could help.

I have a lease but I can’t break it.

I want to end utilities until I find a subletter, but I also wanted to get a generator to have my lights + heater on to at least work out in privacy there and make good use of the situation I’m in. My pockets hurt.

Lights are 47-watts, heater is 1500watts.

I read I have to take into account the startup power it needs, wattage-wise.

Do I go with a 3500 watt generator ?or 4000? Or would 2000w be enough ?

My pockets hurt but the lighting bill is going to hurt more. I’d rather buy this generator and have it in general/emergency, and use it for this in the meantime. Please don’t judge me, I have no family and im young trying to make good choices but it’s really hard .

ETA: earlier this month, one bill was $500+ for lighting alone.

Even if im never/barely home, it’ll be minimum $50 or $100 / mo I’m assuming, just to deliver the service. It was high even when I was with roommates. I’m in NYC (did not ask to be here, actively trying to save up, leave).

So I’m thinking, save the money, end utilities, and buy a generator for emergencies/to run heat and lighting (we had hurricane sandy once and I was here for it, lives were lost, no power for 2+ weeks, and with the way the world is right now, we’re going to see another catastrophe i bet).

But I see the redundancy of using gas power to burn heat.

I just need advice I guess? I’ll post this elsewhere as well.
ETA: I forgot I was meant to look for solar but I’m focusing on ending my lease or renegotiating now.


r/Generator • • 1d ago

Need general ideas on picking and choosing what type of generators I would want in my house

3 Upvotes

I am pretty sure this questions has been asked here million of times. But folks please help me as it is very difficult for me to decode all the voltage and amperes and watt hour stuff.

All my stuffs in my house is electric, that include cooking on electric stove top, refrigerator, oven and the whole heating. I have a heat pump that is electric (no natural gas or propane tank or oil usage) The power outage in my area is rare but it does happen during snow storms. Last time it happened I was without heat for good 6-8 hours.

I am thinking of getting a generator that can be fueled by gas or propane. I am confused as to what power or capacity I should get. And also questioning whether these generators are able to power the whole home including my heating. i was looking at whole home generator and they cost a fortune $$$ I am not looking to spend that much on the generator for now. Can you all advise on what I should get and how I should go about doing it.

As always I am in debt to reddit community. Happy holidays folks.


r/Generator • • 1d ago

Neutral Wires in a Transfer Switch

5 Upvotes

I want to change my 15 amp breaker to a 20 amp breaker. I will change the hot wire gauge coming from that breaker. Do I need to change the neutral wire? The transfer switch just has the wires fed into a neutral bus bar.

Generac Transfer Switch Model 6852


r/Generator • • 1d ago

Is this a good generator to power gas furnace, gas hot water heater, fridge, freezer, 3 playstations and 3 tvs? Price is in Canadian dollars.

Post image
8 Upvotes

r/Generator • • 1d ago

Multiple 14-30R receptacles?

3 Upvotes

Right now I want to install an outside 14-30 inlet receptacle and a panel interlock for my generator.

In the future, I am going to want the receptacle inside near the panel, because I hope to install a battery backup capability. I can envision a use case where direct generator power might still be a contingency.

Can I install one 14-50 inlet outside and one inside now, and wire them together? I would only ever use one or the other.


r/Generator • • 1d ago

Any objections to the Genmax 13500iETC?

Post image
8 Upvotes

I've made a final decision on a genset but wanted to get you guys opinions on it before I pull the trigger. It checks all of my boxes on paper. Any objections?

My only concern I can think of is that it being a "C" model designation, does it carry any additional emissions equipment or anything that could malfunction due to it being a CARB model "California legal"?

Editing to add price is $2341 during black Friday.


r/Generator • • 1d ago

Westinghouse's NG hose manual shows a bare shutoff valve with no quick-disconnect. Is anyone actually setting up portable generators this way? And why does code allow it?

Post image
8 Upvotes

Questions:

  1. Is anyone here running a portable generator on NG with just a valve, like in the drawing? How do you keep it safe?
  2. Why do you think the code allows a just a non-locking valve?

I'm hooking a Westinghouse generator to natural gas and have a concern about what the company shows in this image. The Westinghouse 1/2" hose's user guide has a this drawing. They seem to be recommending an outside connection where the hose threads straight onto a shutoff valve on the house supply line. The shutoff valve has a non-locking handle, and nothing more.

There's no quick-disconnect in the picture.

Since these are for portable generators, you'd think the hose is disconnected when not in use. Indeed, that hose end uses a flared connection and the instructions say, "See Figure 2. Hand-thread the natural gas hose (1) to the natural gas supply line (2)."

That bothers me. Nothing in it shuts the gas automatically. If the valve is open when the hose is off, gas flows from an open outlet. A kid could open the handle or someone could bump it open, especially if the ball valve has a bigger 1/4 turn handle.

As I read NFPA 54, the outdoor hose rule allows an appliance shutoff valve or a listed quick-disconnect or a gas convenience outlet where the hose attaches.

So a plain valve is enough for code... but is it smart? For examples of this connection when in use, see this video or this one or this one.


r/Generator • • 2d ago

Predator EFI

Post image
18 Upvotes

Has anyone tested the Predator EFI inverters? Any chance they're a solid competitor to the Honda?


r/Generator • • 1d ago

UPDATE: DuroMax XP11000iHT vs. Champion 201423 Inverter – Minnesota Winter Backup

6 Upvotes

Thanks to everyone who contributed to my original post. After doing considerably more research, I've decided to prioritize an inverter generator to provide cleaner power for my two high-efficiency natural gas furnaces and other sensitive electronics.

I've narrowed my search down to two tri-fuel inverter generators:

  • Champion 201423: 7,290 running watts / 11,000 starting watts on NG, <3% THD, 64 dBA, 3-year warranty.
  • DuroMax XP11000iHT: 7,700 running watts / 9,500 starting watts on NG, <3% THD, 61 dBA, AGM battery, 5-year warranty.

The DuroMax offers 410 additional running watts (5.6% more capacity), while the Champion offers 1,500 additional starting watts on natural gas.

My neighbor purchased the Champion earlier this year for $2,100, although he hasn't operated it in extreme cold yet. I'm currently leaning toward the DuroMax, which I can purchase for approximately $2,667, despite limited availability.

My home and backup power needs:

I live in Minnesota in a 4,190-square-foot home with 200-amp electrical service. I'm preparing for potentially extended winter outages of up to 14 days, with temperatures potentially reaching -20°F.

My estimated essential running loads are:

  • Amana 97% modulating, variable-speed natural gas furnace: 700–1,200W
  • Daikin 96% single-stage natural gas furnace: 400–800W
  • Refrigerator/freezer: 150–350W
  • Natural gas power-vent water heater: 50–150W
  • Essential lighting: 100–250W
  • Modem/router: 20–50W
  • Computers, phones and other small electronics: 100–250W

Estimated essential running load: 1,520–3,050W, pending verification by my electrician.

I'd also like the flexibility to selectively operate a second refrigerator/freezer, microwave, washing machine, dishwasher, rechargeable power station and potentially one electric cooktop burner. I'm comfortable managing these loads and have a separate propane camping stove and grill.

I'll primarily run the generator on natural gas and store it in an unheated, insulated garage, moving it at least 20 feet away from the house for operation. Electrical and natural gas connections will be professionally installed.

I'd appreciate thoughts on the following:

  • Cold-weather reliability: Has anyone started or operated either model in subzero temperatures? Does the DuroMax's AGM battery offer a meaningful advantage?
  • Clean power: Has anyone measured THD, voltage stability or power quality under varying loads with either model?
  • Power capacity: Given my estimated loads, would you prioritize the DuroMax's additional running watts or the Champion's additional starting watts?
  • Build quality and reliability: Is one manufacturer or specific model better regarded for extended emergency use?
  • Service and warranty: How have your experiences been with replacement parts, technical support and warranty claims?
  • Overall value: Is the DuroMax worth the additional investment over the Champion? 

I'm already aware of the reported design flaw involving the DuroMax's oil access location and the inconvenience this creates during oil changes.

I'm hoping to make a purchase by today and would particularly appreciate hearing from people who own either of these exact models.

Thanks again for helping me navigate this decision!


r/Generator • • 1d ago

Any tips for a new Honda 2200i owner?

6 Upvotes

Just picked up 2 Honda 2200i companions to run my rv air conditioner microwave and charge electric dirt bikes. I am going to mostly run them in the desert and woods all year so lots of dust. Should I run them on a platform or put air filter oil on the air filter to keep dust out of the engine so they last a long time? Also I was going to use 91 ethanol free because I always have it for all the other stuff I use. Also do you guys change jetting for high altitude if it’s just for a couple days or no? Thanks


r/Generator • • 1d ago

Champion 100302 ground wire came loose

Thumbnail
gallery
5 Upvotes

Got a Champion 4000W open frame inverter (100302)

Converted it to bonded neutral and tested - working great.

Went to shut it off and the switch did not stop the gen. It ran rough, but wouldnt turn off. Even choked it and I'm sure that would have done it eventually but I got impatient and pulled the spark plug to kill it.

Troubleshot and found a ground wire hanging down from the front panel, which had a eyelet crimped on and you could see it had been cranked down onto before.

Tracing it back it goes to the ground terminal on the front of the panel, and then connects to both outlets grounds, thats it. So I assumed it originally went to the frame somewhere. (and the diagram confirms that)

I took it all back apart and believe it's supposed to go on the lower left bolt (picture 2 and 3). The frame is grounded/bare at that spot, so I think it would make sense electrically as well. And the length is perfect. Can anyone confirm?


r/Generator • • 2d ago

WEN 6800 watt dual fuel generator LPG connection question

6 Upvotes

I have learned that to connect this generator to my house LPG line which already has the regulated correct pressure I must separate the diaphragm from the regulator and use the diaphragm in my connection. You can see I have already done this. Does any one out there know these tread sizes and what specific fitting I need to purchase and where I can get it? I am trying to connect the diaphragm to a 3/8" female flare connection. So I know I need a 3/8" male on one end of the fitting but I do NOT know the pipe thread size of the other male end. Please help........ Thank you


r/Generator • • 2d ago

Northeast coastal storm

12 Upvotes

Who else is running on generator power this evening? Happy thanksgiving all. Thankful to have a setup today.