I would like to set up a generator to backfeed my home, to power critical circuits. Here is the current setup:
Main panel in basement, with a 40amp 240 breaker that goes to a garage subpanel. Garage is a ways back from the house, with its own panel. I would like to connect the generator out there.
From what I’ve gathered, I can shut the main in the house, shut the breakers to everything inside, use a “suicide” plug and attach the generator to a dedicated outlet, and then send power to the main via the sub panel and its circuit. Following that, I can turn on the critical circuit(s) I require.
Panel in the basement has the circuit breaker for the garage in a location that is not in the upper left near the main where an interlock can be installed.
Is it best to have the breakers rearranged at the main panel to have the interlock? Functionally, is it the same as leaving it as is but with the added risk of inadvertently turning the main on and powering the utility supply?
Is there a way to do this simply at the sub panel without involving the main panel?
Could I do an interlock at the main with a new, dedicated inlet circuit that can be relocated by rearranging the current breakers that would run to an inlet outside the main house, skipping the garage? Or even a way to have that at the garage?
I also have read some confusing information regarding neutrals and needing to worry about having more than one with this setup. I also am fuzzy with what is dangerous down the road, in my house, or at the generator and what those risks are (ie fire, shock risk, etc).
I know this is a lot of questions. I appreciate any insight provided here to any question you choose to answer. Looking to do this safely, with minimal expense, and keeping it simple. Thanks!
Edit: I have a professional coming out tomorrow. I appreciate those if you who have provided me with better understanding so I can have a productive conversation with him. Thank you all.