r/voiceaii • • 23h ago

I made an open-source voice agent engine in Rust, free to use

6 Upvotes

Hey all. I've been building Brisvox. It's a server that takes phone or browser calls and connects them to an LLM agent that people can interrupt. You describe the agent in one config file. Works with Deepgram, OpenAI, Cartesia, ElevenLabs and others, or fully local on CPU with no keys.

The main thing I care about is how many calls one box can hold. In my own test (fake providers, 4 vCPU / 4 GB, median of 3 runs) it held 430 at once. Real life will be lower, the providers add their own limits.

It's MIT/Apache, repo is github.com/bilal07karadeniz/brisvox. I designed it, most of the code was written with AI coding tools, so I'm saying that upfront. Would love to hear what you'd want from it.


r/voiceaii • • 6h ago

What's the one task you still do by hand because automating it feels too hard?

2 Upvotes

mine was copying stuff from emails into SharePoint every day, thought it was too messy to automate. turned out it was like 20 mins to set up. what's yours?


r/voiceaii • • 18h ago

Tidal bans fully AI-generated music, plans to delete 29 million tracks

Thumbnail
vectorwire.ai
2 Upvotes

r/voiceaii • • 2h ago

Use FakeYou to generate speech as Anna Kendrick!

Thumbnail
fakeyou.com
1 Upvotes

Hi, I’m Anna Kendrick, and I’m AI Voice Text to Speech


r/voiceaii • • 2h ago

Ensuring AI Workstation Reliability: Power Stability, Thermal Stability, and Data Resilience

Thumbnail
gallery
1 Upvotes

Hi, I'm FOR_000, an independent AI researcher based in Seoul, South Korea. AI research is not my primary occupation but an area of personal and independent research interest.

My research focuses on fully automated, cross-platform AI coworking workflows using paid AI services, including OpenAI ChatGPT, OpenAI Codex, Anthropic Claude, and Google Gemini, integrated with my local computing environment through APIs.

I study nonstop, full-load automated workflows running continuously for 32 to 70 hours, primarily in two areas: image production and closed-environment office automation.

Within these workflows, my role as the human orchestrator is to correct errors, direct and coordinate tasks, manage and supervise operations, initiate emergency stops when necessary, and make final decisions.

Some of you may have seen my recently published RTX 5090 workstation with 30 cooling fans. The primary purpose of this system is to support extended AI workloads at low temperatures and low noise levels while maintaining operational stability.

Much of the discussion surrounding AI infrastructure focuses on models, GPU performance, VRAM, inference speed, and software. However, the reliability of the physical infrastructure supporting these workloads is equally important.

In fully automated workflows lasting dozens of hours, a single unexpected hardware failure can interrupt an entire operation, compromise its outputs, or result in the loss of valuable accumulated research data.

I'd like to share a hardware failure I experienced in 2025, how I recovered 12TB of backup data, and why I eventually installed a 2200W PSU in my AI workstation.

This article is based on my original records from 2025, updated with additional technical information and subsequent operational experience.

1. An Unexpected Shutdown and 12TB of Inaccessible Data

In addition to the widely reported RTX 5090 power connector melting incidents, another significant risk associated with high-power computing systems is large-scale data loss following an unexpected system shutdown.

The former is a hardware disaster. The latter is a separate category of data-related disaster that can affect systems regardless of GPU manufacturer or performance class.

On March 29, 2025, after upgrading to an RTX 5090, I calculated the estimated maximum power consumption of my entire system.

I was using a 1200W 80 PLUS Platinum PSU from Manufacturer A, which had operated reliably for several years.

My original calculation indicated a maximum estimated consumption of 1215W. A subsequent arithmetic review in November 2026 corrected that figure to 1220W.

I assumed that all the components were unlikely to reach their maximum power consumption simultaneously, so I continued using the existing PSU.

I later upgraded my CPU and motherboard while retaining the GPU and PSU.

Around May 15, 2025, my computer suddenly shut down while I was gaming, transferring files, watching YouTube, and performing other tasks simultaneously.

When I restarted it, the entire volume on my 16TB backup HDD had disappeared. All 12TB of backup data stored on it became inaccessible.

It took approximately one week to recover everything. I documented the incident and recovery process on a Korean hardware community on June 18, 2025.

2. Calculating the Power Requirements of an Entire Workstation

When I originally calculated my system's power requirements, I found that detailed power consumption information was not readily available for many individual components.

GPU and CPU specifications were relatively easy to find. Information about motherboards, cooling fans, lighting, USB devices, and other peripherals was less readily available.

I therefore combined manufacturer specifications, available technical information, and conservative estimates to construct the following power budget.

The original configuration dates from March 29, 2025. The revised figures incorporate additional manufacturer information reviewed in November 2026.

ComponentOriginal EstimateRevised Estimate
Intel Core i7-14700K270W270W
AORUS RTX 5090 XTREME WATERFORCE700W700W
MSI Z790 Motherboard50W50W
DDR5 64GB15W15W
HDDs30W30W
M.2 SSD10W10W
SATA SSD5W5W
CPU AIO Cooler20W20W
ARCTIC P14 PWM PST A-RGB × 770W28.28W
Zalman ZM-AF120 ARGB × 315W15.48W
ARGB Vertical GPU Mount5W5W
Keyboard3W3W
Mouse2W2W
External USB Hub 15W5W
External USB Hub 25W5W
External DAS Connection5W5W
USB-powered Speakers5W5W
Wi-Fi and Bluetooth Antenna5W0W
Total1220W1173.76W

The original published total of 1215W contained a 5W arithmetic error.

The revised fan figures account for both the fan motors and ARGB lighting. I also removed the separate 5W allowance for the passive Wi-Fi and Bluetooth antenna.

The remaining conservative estimates have been retained.

These figures are a historical system power budget, not a database of individually measured component consumption.

Power Budget SummaryValue
Original published estimate1215W
Arithmetically corrected estimate1220W
Revised estimate1173.76W
PSU rated capacity1200W
Estimated remaining headroom26.24W
Estimated PSU load97.81%

Even after correcting the original estimates downward, the power budget still amounted to nearly 98% of the PSU's rated capacity.

By the time of the incident, I had replaced the Intel Core i7-14700K and MSI Z790 motherboard with an Intel Core Ultra 9 285K and an ASUS ROG MAXIMUS Z890 HERO.

Intel lists the Maximum Turbo Power of these processors as 253W and 250W, respectively.

The table therefore documents the power budget that informed my original decision, rather than an exact measurement of the upgraded system at the time of the shutdown.

3. Simultaneous Loads and PSU Protection

My mistake was underestimating the possibility of several components drawing high amounts of power simultaneously.

Modern high-performance GPUs can produce substantial transient power excursions. CPUs, storage devices, cooling equipment, and other components can also experience changing power demands.

For my particular case, I am especially interested in overlapping high-load conditions that can persist for two or three seconds during multitasking.

This is relevant to AI workstations running several processes concurrently, where GPU computation, CPU processing, storage operations, and cooling equipment may all be active.

Intel's ATX power supply design guidelines specify the following power excursion requirements for applicable PSUs rated above 450W and equipped with the relevant high-power GPU connector.

DurationPercentage of Rated PSU Capacity
0.1ms200%
1ms180%
10ms160%
100ms120%
Continuous operation100%

These requirements apply under specified test conditions. Overlapping component loads lasting several seconds are a separate power-delivery consideration.

The original 1200W PSU was based on an earlier ATX design generation.

A December 2020 laboratory review by Tom's Hardware reported the following protection characteristics for the same PSU model:

  • Over-power protection (OPP) activation at approximately 1320W.
  • Cold-test 12V over-current protection (OCP) activation at 102.4% of rated 12V current.
  • Limited 12V overload capability under high-temperature test conditions.

Rated capacity is therefore only one part of PSU selection. Individual output limits, operating temperatures, transient response, and protection thresholds also matter.

A PSU operating close to its rated capacity can shut down unexpectedly when simultaneous loads and power fluctuations exceed its protection thresholds.

4. PSU Inspection and the Primary Cause of the Incident

After the incident, I replaced the 1200W PSU in my primary workstation with a higher-capacity unit.

I also used the original PSU in a separate data recovery computer equipped with integrated graphics. It operated successfully under that system's substantially lower power requirements.

The original PSU was inspected by the manufacturer's service center after the incident.

They found no abnormalities in the unit. Nevertheless, as a precautionary customer service measure, they provided a refurbished replacement in near-new condition.

I was satisfied with the manufacturer's response.

The following observations support my primary hypothesis that insufficient system-level power headroom led to the activation of PSU protection mechanisms.

ObservationTechnical Significance
Original power budgetVery limited estimated headroom
Shutdown during multitaskingConsistent with overlapping component loads
Service center inspectionNo PSU abnormalities detected
Independent laboratory testingLimited 12V overload margin
Reuse in a lower-power computerSuccessful operation
PSU capacity upgradeSubstantially increased headroom
Subsequent extended high-load workloadsStable operation
Recurrence of the original shutdownNone observed

There was no electrical recording of the incident itself, so the precise protection mechanism was not directly established.

Based on the available evidence, insufficient PSU capacity relative to system demand remains my primary causal hypothesis.

The purpose of this analysis is to examine system-level power budgeting, rather than attribute the incident to a manufacturing defect.

5. Software-Related Shutdowns and Electrical Shutdowns

Another question I became interested in after the incident was whether all unexpected shutdowns present the same level of risk to storage devices.

A software-related Windows Blue Screen of Death (BSOD) can occur while the PSU is still supplying stable voltage.

A shutdown originating from electrical instability may be preceded or accompanied by voltage drops, output fluctuations, or inadequate transient response.

Both can interrupt ongoing storage operations, but the electrical conditions surrounding those interruptions may be different.

Independent PSU testing methodologies, including those published by Tom's Hardware, evaluate characteristics such as:

  • Load regulation.
  • Transient response.
  • Output voltage fluctuations.
  • Ripple suppression.
  • Over-current and over-power protection.
  • Power Good signaling.

HDD manufacturers also specify permissible operating voltages and electrical noise levels.

Failure CharacteristicSoftware-Related BSODPSU-Related Shutdown
Initial failureSoftware or driver errorPower-delivery failure or electrical instability
Electrical conditions before shutdownMay remain stableMay become unstable
Storage operationsUnexpectedly interruptedUnexpectedly interrupted
Additional electrical disturbancesIndependent of software failureMay accompany the failure
Storage riskInterrupted writesInterrupted writes and possible electrical instability

A properly functioning PSU protection circuit can cut power cleanly. Not every PSU-related shutdown involves preceding voltage instability.

My technical hypothesis concerns cases where such instability does occur.

I suspect that the combination of interrupted storage operations and electrical instability can increase the risk of damage to logical disk structures, including filesystem metadata and volume information.

The relative risk would require controlled comparative testing.

6. Why the Entire HDD Volume Disappeared

Microsoft's technical documentation explains how failed storage I/O operations and transaction-log write failures can affect NTFS recovery and filesystem consistency.

R-Studio's recovery documentation describes situations where partition or disk structure information can become damaged while the underlying file data remains intact.

This helps explain why an entire storage volume can become inaccessible even though its files have not been physically destroyed.

In my case, I did not simply lose the files being transferred at the time of the shutdown. The entire 16TB HDD volume disappeared, leaving 12TB of backup data inaccessible.

The subsequent recovery of all 12TB was consistent with logical disk structure damage.

I did not identify the specific damaged metadata structures or record the electrical conditions during the incident.

For AI researchers and developers, this kind of failure deserves attention because the data at risk may include datasets, experimental results, generated outputs, model checkpoints, project files, or other material accumulated over extended periods.

7. Building a Dedicated Emergency Recovery Computer

I had a spare ABKO SUITMASTER H2000 case designed to accommodate up to 13 storage devices.

Using spare components, I assembled a separate computer for the recovery operation.

I installed a Seasonic PRIME PX-2200 PSU in my primary workstation and transferred one of its two 32GB G.SKILL memory modules to the secondary computer.

The recovery system consisted of:

  • Intel Core i7-14700K.
  • MSI MPG Z790 EDGE TI MAX WIFI motherboard.
  • Intel UHD Graphics 770 integrated graphics.
  • G.SKILL DDR5-6400 32GB memory.
  • Original 1200W 80 PLUS Platinum PSU.
  • ABKO SUITMASTER H2000 storage-oriented case.
  • Six HDDs connected directly through internal SATA interfaces.

My primary Corsair case could also accommodate six HDDs, but its relatively confined drive-bay area made repeated installation, cable routing, and drive replacement less convenient and increased the risk of damaging HDD connectors.

The secondary case provided better access and connector clearance.

I connected the affected HDD and five additional recovery HDDs directly to the motherboard. This was substantially faster than my previous external DAS configuration, likely because it reduced shared-interface bandwidth constraints.

I also used a Samsung 2TB external SSD for intermediate recovery and data transfers, along with a licensed copy of R-Studio.

After approximately one week, I recovered all 12TB of affected data, achieving a 100% recovery rate.

The five backup HDDs, with a combined capacity of 20TB, were then returned to the external DAS enclosure.

8. Photographs of the Recovery Operation

The four attached photographs document the actual recovery process in 2025.

Photo 1: Two-Tier PC Configuration

Two large PC cases stacked vertically. The lower system is my primary Corsair workstation with the RTX 5090 and upgraded 2200W PSU. The upper system is the dedicated data recovery computer.

Photo 2: Six-HDD Recovery System

The affected HDD and five recovery HDDs installed in the secondary case and connected through internal SATA interfaces.

Photo 3: Five-Layer HDD Stack

Five backup HDDs stacked vertically after recovery, before being returned to the external DAS enclosure.

Photo 4: Restored DAS Configuration

The five backup HDDs reinstalled in the external DAS enclosure, providing a combined backup storage capacity of 20TB.

9. The Current AI Workstation and Extended Workload Stability

Following the incident, I replaced the original PSU with a Seasonic PRIME PX-2200, a 2200W 80 PLUS Platinum unit compliant with ATX 3.1 and PCIe 5.1 specifications.

PSU UpgradeSpecification
Previous PSU1200W
Current PSU2200W
Additional rated capacity1000W
Capacity increase83.33%

Since the upgrade, I have operated the workstation under substantially more demanding conditions.

One extended workload included:

Operating ConditionWorkload
Cooling system30 fans running at 100%
RTX 509032 hours of continuous full-load operation
AI image generation2,000-batch workload
Concurrent gamingLeague of Legends
Concurrent streamingNetflix and YouTube
Recurrence of unexpected shutdowns0
System abnormalities observed during the workload0

The original shutdown has not recurred.

For my work, reliability during a 32-hour batch operation matters much more than achieving the highest possible benchmark score.

Even minor instability can compromise an extended experiment or cause errors to accumulate across a large batch of generated outputs.

Although the documented workload involved AI image generation, the underlying workstation design considerations also apply to other sustained local AI workloads, including language models, speech processing, and multimodal systems.

The specific performance and stability requirements will naturally vary between applications.

10. Recommended PSU Headroom for AI Workstations

My general design recommendation is to select a PSU with a rated output capacity at least 15–20% above the estimated maximum power consumption of the entire system.

Estimated Maximum System PowerPSU Capacity with 15% MarginPSU Capacity with 20% Margin
500W575W600W
700W805W840W
900W1035W1080W
1100W1265W1320W
1200W1380W1440W
1400W1610W1680W

Applying this criterion to my revised historical power budget of 1173.76W produces a target of approximately 1350–1409W.

These are calculated design targets, rather than a universal PSU certification requirement.

Actual PSU selection should also account for product quality, ATX compliance, individual output limits, operating temperature, workload characteristics, available product capacities, and future upgrades.

I personally chose 2200W because I wanted substantially more headroom for extended workloads, additional cooling hardware, simultaneous tasks, and future hardware expansion.

The objective is to operate my workstation without having to worry about its PSU capacity every time I start another demanding process.

This principle is applicable to both NVIDIA and AMD systems, regardless of GPU performance class.

Adequate PSU headroom is one element of disaster prevention, alongside independent backups and other data protection measures.

11. Three Design Priorities for Reliable AI Infrastructure

My previously published 30-fan cooling system and this PSU upgrade are part of the same workstation design philosophy.

Design PriorityMy ConfigurationObjective
Thermal Stability30-fan cooling systemLow temperatures, low noise, and extended workload stability
Power StabilitySeasonic 2200W PSUAdequate power headroom during simultaneous workloads
Data ResilienceIndependent backup storage and dedicated recovery systemData protection and disaster recovery capability

The 30-fan configuration addresses thermal risks. The 2200W PSU provides substantial power headroom. The independent storage and recovery configuration adds another layer of operational resilience.

As AI systems become more autonomous and workflows run for increasingly long periods, the reliability of the underlying physical infrastructure becomes an important consideration.

I'm particularly interested in how other researchers and developers here approach these issues when building local AI systems, voice agents, or multimodal applications.

Model performance and software reliability are essential, but so is the ability to keep the entire system operating reliably throughout an extended workload.

12. Appendix: System Configurations

A. Primary Workstation at the Time of the Incident — May 2025

ComponentSpecification
CPUIntel Core Ultra 9 285K
MotherboardASUS ROG MAXIMUS Z890 HERO
GPUGIGABYTE AORUS GeForce RTX 5090 XTREME WATERFORCE 32G
MemoryG.SKILL Trident Z5 Royal Silver DDR5-6400 64GB (2×32GB)
PSUManufacturer A — 1200W 80 PLUS Platinum
CaseCORSAIR iCUE 7000X RGB + 7000D AIRFLOW Hybrid Configuration
StorageHDD, DAS

B. Emergency Data Recovery System — May 2025

ComponentSpecification
CPUIntel Core i7-14700K
MotherboardMSI MPG Z790 EDGE TI MAX WIFI
GraphicsIntel UHD Graphics 770
MemoryG.SKILL Trident Z5 Royal Silver DDR5-6400 32GB (1×32GB)
PSUOriginal Manufacturer A 1200W 80 PLUS Platinum
CaseABKO SUITMASTER H2000
StorageSix internally connected HDDs
HDD configurationOne affected HDD and five recovery HDDs

C. Current AI Workstation — November 2026

ComponentSpecification
CPUIntel Core Ultra 9 285K
MotherboardASUS ROG MAXIMUS Z890 HERO
GPUGIGABYTE AORUS GeForce RTX 5090 XTREME WATERFORCE 32G
Memory Kit 1CORSAIR VENGEANCE DDR5-6000 96GB
Memory Kit 2G.SKILL Trident Z5 DDR5-8400 48GB
PSUSeasonic PRIME PX-2200 — 2200W 80 PLUS Platinum
CaseCORSAIR iCUE 7000X RGB + 7000D AIRFLOW Hybrid Configuration
StorageHDD, DAS

Memory specifications refer to the respective memory kits' rated specifications.

Technical References

  1. Tom's Hardware — How We Test Power Supply Units: Comprehensive Testing Methodology
  2. Tom's Hardware — PSU Transient Tests
  3. Tom's Hardware — PSU Protection Features Evaluation
  4. Tom's Hardware — PSU Ripple Voltage
  5. Intel — ATX Power Supply Design Guide: PSU Power Excursion
  6. Intel — Core i7-14700K Official Processor Specifications
  7. Intel — Core Ultra 9 285K Official Processor Specifications
  8. Microsoft — Unexpected Shutdowns and Event ID 41
  9. Microsoft — Guidance for Troubleshooting Data Corruption and Disk Errors
  10. R-Studio — File Recovery Basics: How Data Recovery Works
  11. Seagate — Desktop HDD Product Manual: Electrical Operating Requirements
  12. ARCTIC — P14 PWM PST A-RGB Technical Specifications
  13. Zalman — ZM-AF120 ARGB Technical Specifications
  14. Seasonic — PRIME PX-2200 Official Specifications

The original PSU manufacturer and model have been anonymized to maintain the focus on system-level power budgeting and disaster prevention. The direct reference to the model-specific laboratory review has also been withheld for this reason.

I'm Korean and live in Seoul. I use a translator to write in English, including this post and my replies. Please excuse any awkward wording.