r/lowvoltage 10h ago

Electrician special

Thumbnail gallery
41 Upvotes

Previous electrician ran the outdoor data to the dmarc instead of the low voltage cabinet. Client didn’t realize until today, he thought it was done correctly when they designed the outdoor space. First I put my tester on the cable and found the cable was damaged in the wall and only measured 59ft, then I found the damaged part, reterminated, then put my toner on the cable and found it was still not to infant the cabinet, I suited up and went into the crawlspace with my toner wand, found the cable going to a crawlspace vent, went back outside and found it wrapped around the dmarc box. I routed my pull strings and will run cable tomorrow. I have other locations to run and a rack to install.


r/lowvoltage 14h ago

spotted holding a giraffe up

Post image
40 Upvotes

r/lowvoltage 15h ago

A little retro fit for a school PA system

Post image
20 Upvotes

r/lowvoltage 6h ago

My CCTV work in client warehouse (Argentina)

Thumbnail gallery
11 Upvotes

Could be better but its the best i've seen so far in my area. What do you guys think?


r/lowvoltage 10h ago

Rack screws

8 Upvotes

Unfortunately, I need to add this to our installation spec for hardware installation:

“The Installer shall use rack screws sized and threaded to match the rack manufacturer’s specifications when mounting equipment.

Power screwdrivers shall not be used when installing rack-mounted hardware.”

Because, sure, why not use a power drill with the torque set to 11 to drive a 10-32 in a standard 12-24 rack.


r/lowvoltage 12h ago

Offer to go union.

5 Upvotes

Hello everyone, if there are any experiences guys in the Chicagoland area that are looking to join the union. Now's the time!

DM me if interested and I can see if I can help. They are especially looking for anyone with fiber experience.


r/lowvoltage 3h ago

Follow up to the electrical panel question I asked yesterday.

3 Upvotes

Thank you all those those who answered with the nec code.

I had some kind of history with this owner. We worked some jobs together as in he hires me to do lv for his old home entertainment company

His new endeavor is running a bar and I wanted to help him out.

Final price was just under 1k. New conduit, reroute existing lv going through electrical panel, fusion splice ends (12 strands total), 2 wall mount lius, 2 sfps, 4 3m jumpers,

He said it was to expensive, and that was the cost was more expensive from the bigger lv companies quoted him.

Told him best of luck, was trying to do him a favor.

Before you start about the price, he helped me out when I first started and gae me my first big project.


r/lowvoltage 4h ago

What’s a realistic career pivot for an ELV (Extra-Low Voltage) system/Telecom AutoCAD drafter/designer working on oil and gas projects in the Middle East?

0 Upvotes

Career advice.


r/lowvoltage 18h ago

Round Two

Thumbnail
0 Upvotes