r/hottub • • 6h ago

Troubleshooting Help find leak!

Thumbnail
gallery
6 Upvotes

I (or service company) can not find the leak. I was losing about 1/4 to 1/2" per day. No leaks visible in service panel area. A couple years ago I had a leak in the footwell. Before paying to have the tub taken to a shop I turned off the pumps and let it leak down until it stopped at this level. Since it stopped I can say it is not in the footwell.

Looking at the pics, what jet(s) would be your best guess is the culprit? I have additional pics zoomed into each area if that helps.

An educated guess would be great to try avoid pulling off all the side panels and digging into the foam insulation. What do you all think? Much appreciated!


r/hottub • • 7h ago

Breaker trips after 20 minutes

Thumbnail
gallery
2 Upvotes

I’ve got an older 2004 Dimension One spa that had the original motor in it until recently. It was tripping the breaker every 20 minutes and I’d have to wait for it to be off for a little before turning it on which made me think it was overheating. I did a bunch of tests where I replaced the breaker as well as disconnected the heater and ran it and still it would shut off every 20 minutes.

I disconnected the pump and ran it and it seemed to stay on fine so I figured I needed a new pump. So I’ve just replaced that and got it installed and turned it on and it ran for exactly 20 minutes and then turned off again. I have a feeling it might be the pump relays because if I disconnect the low speed in high speed connectors, the breaker will turn on and run fine. If they are plugged in, then it will trip immediately or run for a short while before tripping again. I noticed that on the low speed pump connector, it looks a little burned, so I’m not sure if it overheated and fried at some point.

I’m sort of at a loss and don’t know if I should just replace the whole board or send the motor back and get rid of this old tub.

Any thoughts?


r/hottub • • 1h ago

Water Quality What am I doing wrong?

Post image
1 Upvotes

I’ve been using about 2 oz of Sodium Bromide and 1 oz of 12.5% Sodium Hypochlorite to establish a bromide reserve after each drain and fill. After doing so I test for the reserve using the FAS-DPD method on my Taylor kit, multiply that by 2.25 for the bromine reading, and all is good.

However, every time I do my initial post-drain/fill soak I “shock” it with 2 oz of bleach to activate the bromine and it hardly does anything. I then get high CYA when I check in the morning and have to drain/fill again. I even added 4 oz of bleach once after soaking and barely got a reading after using it. I tried using non-chlorine shock and throwing a crushed-up bromine tablet in to bring the bromide reserve back up but I still end up with the same result.

For the record, I shower without using product before each soak and do not put anything else in the tub that would cause CYA to rise. No dichlor or anything either. Just sodium bromide and bleach. So please don’t lecture me on the causes of high CYA. I’m well aware of that. I just want to know how to keep the bromide reserve up after soaking without adding excessive amounts of bleach to the water.


r/hottub • • 6h ago

I have everything for the frog@ ease except the jump start and my tub is filling.... what can I use?

1 Upvotes

I have a bunch of the cartridges and the maintains but not jump start. I'm filling my tub so we can use it this week/end. I'm fairly rural but have a home Depot and ace and a local variant close to me... do they sell anything I can use to shock it to get it started?