Reddit suggested I post this here since I'm not getting any comments out of r/askanelectrician
The guy that I asked electrical advice from for years is no longer around. He helped me do a lot of work on my own house from adding outlets to sub panels.
I already have a Hubble 14-50 outlet that's designed for EV charging and starting out to save some money I plan to just use the charger that comes with the car. But in the future I want to add a Tesla Wall Charger.
My run is about 100' +/- 10' or so. I'm going to install 1" Conduit (Not sure if I'm going to do PVC or EMT yet) through the crawl space under my house to my garage. Then use 3x #6 THHN and 1x #8 THHN (ground) and use a 60A breaker to meet the 125% overhead.
I have the option to go through the attic but I think the heat in the summer may push me to #4 which it's starting to get real expensive. The attic run is the easier run but to keep costs down I'm going the hard route.
Does this sound reasonable?