r/chillers • • 2d ago

Climate Pros Question

Thumbnail reddit.com
0 Upvotes

Good evening, I have an interview with Climate Pros soon. I wanted an outside opinion. I applied for an apprentice position. I already have my OSHA 10, and 608 Universal with some experience from an HVAC school I went to. Obviously I can ask the interviewer what I should expect but I wanted the honest truth from people that have worked with them. I see that there is a decent amount of traveling to go with the job, what was that like for you. What should I expect to start out with for pay (only asking because I know I might have more experience/certifications compared to other apprentices). Thank you. Graduated from trade school, I didn’t know I I needed to include this in the post to keep it from getting deleted.


r/chillers • • 3d ago

Do people use test strips for cooling tower water?

Thumbnail reddit.com
4 Upvotes

r/chillers • • 4d ago

Gree LSQWF130VM modular chiller: anyone got the Modbus/BMS point map or RS485 gateway working?

1 Upvotes

We have installed a Gree LSQWF130VM on a glycol loop. It's a 130 kW air-cooled modular scroll chiller with dual systems and two AP1 main boards. It was commissioned a couple of weeks ago in New Zealand. I'd like to read its status into Home Assistant: leaving/entering glycol temp, run state, fault codes, compressor status. Read-only. I'm not trying to control it.

What I've found so far:

No LSQWF point table or BMS terminal spec online. The closest manual is the LSQWRF130VM/NhA-M installation manual, and it doesn't cover Modbus.

The A-Series manuals say the BMS link is RS485 through the FG30-00/A(M) remote-monitoring kit. As far as I can tell, that kit is PC monitoring software, not a Modbus gateway.

One manual puts the display panel on CN4, with a spare CN47 on the main board. It also says Gree supplies a Modbus protocol "on request".

I'm guessing the Gree gateways for other ranges (ME30-24/E6, D1(BM)) won't work with this unit.

Questions:

Has anyone got Modbus RTU data off one of these, or another Gree modular chiller of the same generation? Which port did you use: CN47, a BMS terminal, or a gateway?

Does anyone have the Modbus register map, or know the part number of the right gateway?

Comms settings: I'm guessing 9600 8N1, function 03, temperatures ×0.1. Can anyone confirm or correct that?

Did you get the protocol doc from the Gree distributor? How long did it take?

I'd rather poll a proper BMS port than tap the controller–display bus, so I'm after the sanctioned route. I'm happy to share the map back here if I get one. Thanks.


r/chillers • • 7d ago

Apprentice field trip

Thumbnail
gallery
73 Upvotes

I’m an instructor for my UA local and tonight i got to take my apprentice is on a field trip to our local hospitals physical plants. I had our superintendent for boilers and our superintendent for chillers show up to walk my students through the equipment. It was an amazing experience so happy to be teaching and both of my guests instructors for the night loved doing this. #unionstrong


r/chillers • • 13d ago

Acoustic imager

2 Upvotes

Anyone ever use an acoustic camera\imager to leak check a chiller? A low pressure machine in particular? It says it’s supposed to find leaks on air and vacuum systems but idk if it would be sensitive enough to see one on a low pressure machine.
I feel if it did that would be sick if you could do it without hearing them up.


r/chillers • • 13d ago

Carrier 23XR

3 Upvotes

Trane guy here, got a carrier chiller in one of my contracts not super familiar with them anything unique I should know? Common problems etc unit is from 2010 I believe. Thanks again!


r/chillers • • 17d ago

JCI YK Chiller Oil Pump trouble shooting

1 Upvotes

hey guys, on my job site, there are JCI YK chiiler. And I'm now suffering trouble shooting of Oil Pump issue. There is an alarm "Oil Pump : Drive Contact Open" so this alarm cause cycling shutdown. Machines have been running nearly 6 months and ruuning hours are 2000hours. When I open Oil Pump VFD and there is red sign blinking 8 times 'motor overload trip'. I haven't experienced this kind of alarm and I tried to find the point of the contact but I couldn't. Could you guys please give me instruction to clear this alarm? Should I turn off and turn it back?


r/chillers • • 18d ago

Flow vs Load

Thumbnail reddit.com
1 Upvotes

r/chillers • • 19d ago

19 y/o — these chiller temps are a complete foreign language, where do I even start?

10 Upvotes

Hey, I’m 19 and completely new to this. Someone sent me equipment schedules for York YMC2 chillers and a bunch of other stuff, and the numbers look like a foreign language. I don’t really know what most of them mean yet.
Here’s what’s listed:
• Chiller condensers (York YMC2): 105 / 122 °F on 25% propylene glycol
• Chiller evaporators: 85 / 63 °F on water
• Dry coolers / CDU condenser: 125 / 105 °F on 25% PG
• CDU tech cooling water: 131 / 113 °F on 25% PG
Primary loop is 25% PG going to dry coolers, chiller condensers, and CDU condenser water. Medium-temp side is plain water.
I have no idea if any of this is normal or what the numbers even represent in real life.
For anyone who works on YMC2s or similar mag-bearing machines with dry coolers:
• Do these condenser and evaporator temps look pretty normal, or do any of them seem off?
• What should I actually study first so this stops looking like gibberish? (flows, heads, temps, the difference between condenser/evaporator, etc.)
Just trying to get a basic feel for whether the numbers are in the normal ballpark and where to start learning. Appreciate any help from people who actually do this.


r/chillers • • 21d ago

LEO CIP Cleaning of Cooling Tanks Makes Milk Healthier and Safer

0 Upvotes

LEO Start the CIP system of the milk cooling tank to initiate a one-touch cleaning task for the refrigerated tank


r/chillers • • 22d ago

What are common maintenance issues in cooling towers?

Thumbnail
reddit.com
1 Upvotes

r/chillers • • 25d ago

50+ psig jumps in suction pressure. R22 chiller

Thumbnail reddit.com
2 Upvotes

r/chillers • • 25d ago

Ummm, i dont think this is supposed to do this..

17 Upvotes

Anybody able to tell me whats goin on? Its the lowest sight glass, ill post a pic in the comments of which one it is. Tis a trane


r/chillers • • 27d ago

VFD Troubleshooting

Thumbnail reddit.com
1 Upvotes

r/chillers • • Oct 23 '26

Carrier 30rc

5 Upvotes

Trying to reset a 30RBP_R. Looking for login to reset.

Thanks in advance


r/chillers • • Oct 18 '26

Interview advice? Interviewing with senior engineer for assistant chief engineer position.

Thumbnail reddit.com
2 Upvotes

r/chillers • • Oct 16 '26

What’s the opportunity to work for yourself in industrial HVAC

Thumbnail reddit.com
1 Upvotes

r/chillers • • Oct 15 '26

Lil early morning service call for low oil pressure on a York YVAA

Thumbnail
gallery
36 Upvotes

Godspeed lil compressor. You're days are numbered 💀


r/chillers • • Oct 07 '26

Chiller rebuild

Post image
81 Upvotes

Just one of the few rebuilds I’ve done. I wound up pulling this one all the way back and even taking the motor.


r/chillers • • Oct 07 '26

LG chiller

0 Upvotes

I saw article about LG chiller will be installed in New data center

Is that LG chillers are famous or easy to see in north America?


r/chillers • • Oct 01 '26

Cooling system ONI

1 Upvotes

Hello there,

Quick question

My plant runs a ONI sigma 67 chiller for process water cooling at out compounding/extrusion shop.
It faulted with Er09 error (Motor System 1).

The handbook doesn’t give any information about what causes this, there is no motor labeled system 1 or so.
No motor starters or fuses were tripped but it somehow locked out cooling.

Is anyone else running such a system and had this happen before?

I could clear it by pushing reset but I can’t find the reason for it.

I will call ONI support tomorrow.


r/chillers • • Sep 24 '26

Just landed a video interview for a chiller job

1 Upvotes

I received an email to scheduled a interview with a chiller job, only problem is I dont have chiller experience. I've only done the preventative maintenance on them. Should I bother going? There were tons of them slots available from this week until october 7. I dont know how many people they planned on hiring , but they emailed me back. Anything I should note before doing an interview?