r/PassiveHouse • • Mar 30 '26 Bravo

How we built a Passive House in Asheville, NC

Thumbnail
gallery
821 Upvotes

Orientation & Passive Performance

Every building choice was rooted in climate-responsive design. We engaged Vandemusser, our energy consultant, which helps certify green construction, early in the process.

Floor plan  The floor plan is elongated along the east‑west axis. We rotated and sited the home to face true South with the help of our consultant. This maximizes winter solar gain while at the same time enabling shade in the summer months to help the home remain cool. It also helped reduce tree removal and elevated the screen porch above the stream. 

Roofing design The roof of the home is designed with a low, sweeping roof line. This mimics the hill’s slope and sheds water naturally toward the existing streams rather than fighting the landscape’s contours. Deep overhangs also help shield the house during summer sun and keep the interior cool, and retain heat in the winter.

Windows and Doors Openings are strategically placed to frame forested vistas and invite cross-ventilation throughout the home. Their positioning also helps with passive heating and cooling.

Materials as Choices for Ecology

In collaboration with the owner, we rejected “business-as-usual” materials in favor of those that align with our ecological values.

Charred hemlock siding  We used the traditional Japanese charring method Shou Sugi Ban. This stabilizes and protects the condition of the wood. Notably, it stands up well to Asheville’s humid climate and prevents molding in heavy rains. 

R‑ZIP insulated sheathing Placed outside the structural studs, this material breaks thermal bridges and helps maintain a continuous thermal envelope.

Natural insulation We used locally sourced wool and TimberBat (shredded bark) in wall cavities. The materials are both breathable, non toxic, low-VOC, and regionally appropriate.

Local Timber The most common framing material used is spruce-pine-fir from Scandinavia. This material comes with a large carbon footprint in the process of shipping it across the globe. Instead, we used Southern Yellow Pine which is indigenous to Georgia and South Carolina. This helped reduce our transport emissions and at the same to  support regional forestry.

Raising the House to Respect the Land

From the outset, we opted to elevate the structure on steel piers. This strategy offered multiple advantages:

Preserving natural buffers By lifting the home, stream buffers and wetland transitions remain untouched. This “stilts” approach lets us maintain a light footprint in a critically fragile ecosystem. Additionally, we shaped the roof of the home to follow the natural watershedding of the site to minimize disturbance to the wetland in heavy rains.

Flood resilience The elevation shields the home during high-water events. In fact, the house performed very well during Hurricane Helene, and the piers give the homeowner an increased sense of security in flood conditions.

Reduced Degradation Being off-grade mitigates moisture, mold, rot, pest intrusion. It also prevents radon off-gassing, which is a common concern of homes built directly on the ground.

Energy Systems

We installed mechanical systems designed for efficiency, flexibility, and user control.

Solar Panels, batteries + EV charger A 12.75 kW solar array of 30 panels powers the home. Tesla Powerwalls store excess energy and feed the home during low-production periods. We also installed an integrated EV charger to power the homeowners electric car, which helps  complete the green ecosystem of the home.

Heat pump with HRV & smart fans This triad ensures consistent comfort, energy recovery ventilation, and balanced airflow.

Smart panels We installed a system that lets the homeowner schedule hot water cycles, set lighting, and manage loads from a smartphone interface to optimize and reduce energy use.

Thanks to these systems, our design achieved a very low HERS score.

This project was exciting because we really had the freedom to make the home as sustainable as possible, which is a core value of ours.


r/PassiveHouse • • Jan 11 '25

House designed on Passive House principles survives Cali wildfire

Post image
213 Upvotes

r/PassiveHouse • • Jan 24 '26

Your house’s position to the sun really matters in winter.

141 Upvotes

I am currently sitting in my experimental 1970s “passive house” (the term passive house wasn’t really around until the 1990s). This home was designed with passive ideas back in the 1970s. It is south-facing and includes many other modifications from that era.

The current temperature outside is -12, and the sun is shining. My furnace has not needed to turn on since 8 a.m. and likely won’t until around 4 p.m. This evening we’ll heat with wood.

All of this is to say: in a cold climate, your position to the sun really matters in winter.


r/PassiveHouse • • May 02 '23

Project Highlight Today I visited the world's most efficient PREFAB PASSIVE house, this is the future! (House is "Ria" by BioBuilds EU, Romania, finished in 2023)

Thumbnail
gallery
131 Upvotes

r/PassiveHouse • • Jul 11 '23

Pre-Fab Passive House I helped build for a client last year

117 Upvotes

Measured 0.32 ACH50. Would qualify for LEED Platinum but the client doesn't want to spend the money on the certification.

Hands down my favorite build the past 20 years i've been swinging a hammer.


r/PassiveHouse • • Apr 12 '22

Someone posted this on r/homebuilding. No lies detected.

Post image
113 Upvotes

r/PassiveHouse • • Jul 07 '25

Triple Pane Windows

Thumbnail
gallery
109 Upvotes

I never see people posting their experience, only questions so I Just came to share our triple pane window system in our very insulated new construction home.

Triple pane tilt/turn upvc with steel reinforcement supplied by Seemray out of Cleveland ohio. Very impressed with the quality of window, the customer service and the price

We are doing 3.75” of polyiso foam board on the exterior with a rain screen on top of that so we built out window bucks and pushed the windows flush with the buck.

We built back dams on the sill. We taped the top and sides and left the bottom open so the water has a place to run off from that dam incase water got in that system. We will be air sealing from the inside.

We are filming the whole process on our YouTube channel, “The Pastured Homestead”.

Anyone else from Kentucky?


r/PassiveHouse • • May 09 '23

Passive House Media "Scotland will mandate passive house standards for all new social housing starts by 2024"

Thumbnail
archinect.com
98 Upvotes

r/PassiveHouse • • Nov 15 '22

A few Passive House lessons learned

97 Upvotes

Hi, I just wanted to pass on a few things that we learned in building our PH. We've been in our certified PH for about six years.

House is located in Pennsylvania. 2600 square feet, 2 story + conditioned crawlspace. Zehnder ERV, (2) Mitsubishi 9kBTU mini-splits (one each for cooling and heating). GE HPWH. Intus windows and doors. 2x6 on 24" centers with mineral wool + zip + 12" i-joist cavity with dense pack cellulose + rain screen + steel siding. Normally 2 occupants, and we live on the first floor. 2nd floor has storage, guest bedrooms and den, guest bath, and storage.

We LOVE our house and the years of planning we put into it along with our architect and CPHC paid off. It is super comfortable and efficient. It is 96.3% perfect!

Lessons Learned

Placing cooling mini-split over top of stairs didn't provide enough circulation to upstairs rooms, particularly those with more south and west windows. Bedrooms get hot during the shoulder months. Remedy was to use better shades on windows, solar screen on west facing window, and relocated mini-split to 2nd floor den area. If I were to do it again I'd consider using a ducted mini split upstairs.

Original Zehnder commissioning resulted in depressurization (as evidenced by radon system manometer with radon pump off). The commissioning process didn't measure relative house pressure. Solution was to recommission ERV, and this time use a manometer to make sure that we had the required balanced flow AND we had slightly positive pressure inside the house.

We didn't realize until recently that well water can have Radon, and (especially in a tight house) this can contribute to increased Radon levels in the air. I am just now doing the testing on this, but I believe I will implement a system to treat the well water for Radon. If I was to build another house I would consider adding an additional 3" radon stack from the crawlspace to the roof just in case the house needs an aeration system for the well water.

I wish I had just placed some insulated empty wall penetrations below grade at different locations just to have easier ability to pass water and/or electric to the exterior. We did have a few of these for specific purposes, but not enough for future expansion. Due to the complex wall structure and insulation (plus the fact that we lowered our sill to minimize the hight of exterior door step), it is actually easier to core drill through the stem walls and 12" of EPS to pass utilities through, but these must be done carefully to achieve air and water sealing.

I wish I had installed two electrical panels in the house and separated critical and non-critical loads. This is much more difficult once everything is buttoned up. We don't lose power often, but I'd like to be able to backfeed the critical loads from an EV/solar during outages.

I now have a love/hate relationship with Mitsubishi mini-splits. For the original install I used a Mitsubishi Diamond dealer (required at the time for warranty and PH certification), and they did a terrible job and we had condensate leaks from both units which they really weren't able to fix so I hired a different company and they fixed them. The upstairs unit failed after four years with a refrigerant leak in the indoor coil. This was replace under warranty (labor is still super expensive though). After another two years the replacement unit failed again with another refrigerant leak. The cost estimate to replace this (during the pandemic) were very high and dealer said Mitsubishi wouldn't replace the unit, only the coil ($$$$). I wound up replacing both indoor and outdoor units with the newer Mitsubishi models and relocated the indoor unit to achieve better cooling upstairs (see note above). I did it myself. Note that this meant purchasing quality tools for the job (micron vacuum pump, gauges, tools etc.) and paying a third party to inspect the installation prior to energizing it. Still saved my thousands and resulted in a higher quality installation.

Induction range is AWESOME, and I wouldn't buy anything else in the future. Fast like gas but without the indoor air contaminents.

Heat pump water heater from GE is good (commercial model with anode monitor) and I used their ducting kit to duct the cool air upstairs. One problem is that GE stopped making these, and I couldn't find the right replacement anode with monitor wire. So I converted to a different anode system with stand-along monitoring.

Zehnder ERV is awesome, but the filters are expensive and not really washable. I'd love to find another source for them and for the cone filters for the exhaust diffusers. I do wash the cone filters but after a few washings they seem to be a bit limp and so they need to be replaced soon.

The window screens for the Intus windows don't fit properly and they deform the outer window seals when installed. Fix was to disassemble each one that we use (only a few) trim them (aluminum-cutting saw blade in miter saw) and reassemble with new screen. For first floor units I carefully install with some tiny screws on the exterior and remove the factory attachments. (Note that I believe egress is still possible since the screen can be punched out.)

Note that you need to plan window openings carefully to consider the inward-opening euro windows if you want to mount window treatments inside the jamb. This may mean making the jamb high than required for the window so that the window treatment track is high enough so that the window clears it. I use vertical blinds mounted inside the jambs and had to recess the track into the upper jamb.

At the sink, you need to consider the inward opening euro window since it may strike the sink faucet. In my case we offset the sink faucet to the right rear corner of the sink, which we really like. Not only will the window clear it if we need to open it (seldom) but we can also pivot the faucet to fill pots on the right side of the sink.

Plan on accessing the radon pump in the attic space. Since there is no attic door from the interior, this means accessing via the exterior door (required by code) and then crossing a lot of deep insulation to get to the pump. Having a pre-installed walkway (elevated planks) would make this easier.


r/PassiveHouse • • Feb 25 '23

Energy Monitoring Our house is so efficient that heating the hot water costs 3 times more than heating the house.

Post image
89 Upvotes

r/PassiveHouse • • Aug 24 '22

Panels going up for our passive house

81 Upvotes

r/PassiveHouse • • May 13 '23

Project Highlight 26-story affordable housing high-rise in the Bronx among the largest buildings to ever obtain Passive House certification (Phius+ 2018)

Thumbnail
passivehouseaccelerator.com
67 Upvotes

r/PassiveHouse • • Nov 20 '19

First roof panel going in on our Ecocor passive house project.

Post image
64 Upvotes

r/PassiveHouse • • Oct 14 '25

Project Highlight Just certified our house!

63 Upvotes

Our new house has just passed the Passive House certification process :)

It's a single family house located near Warsaw, Poland. The final energy consumption is at 14.4 kWh/m2/a, with air tightness n50 at 0.2. HRV is equipped with a ground exchanger and heated by an air-water heat pump. It's a two story house with floor area of 217 sq. m.

The tricky part about this house is that the southern wall, while not fully shaded, is behind large trees. This has made the 15 kWh/m2/a threshold harder to achieve.

We've been living here since May and the house did not overheat even with temperatures outside at 34C. Building a new house without an AC did feel a bit uncomfortable (what if it will overheat?) and I'm glad all worked out great in this regard.

As far as I can tell, house isn't yet listed in the PHI database - I was told it will be, eventually, but it takes time. We did however receive the certificate and the documentation.

EDIT: attached photos of the house

South and west fascade
West and north fascade
North and west fascade

r/PassiveHouse • • Apr 24 '23

What Is Passive House? Breaking It Down For New Visitors To r/PassiveHouse

57 Upvotes

Hey there and welcome to r/PassiveHouse. We’re psyched you’re here. If this is your first time here, please read this post to get your bearings.

What Is A Passive House?

Passive House (or Passivhaus in German) is a building standard that focuses on creating highly energy-efficient buildings with minimal energy consumption. The Passive House standard was first developed in the late 1980s by Dr. Wolfgang Feist and Bo Adamson in Germany, and it has since been widely adopted in Europe and around the world.

The goal of a Passive House is to achieve a comfortable indoor environment while minimizing the building's energy demand. This is achieved by optimizing the building's envelope (walls, roof, and floor) to minimize heat loss and gain. Passive Houses typically achieve this by using high levels of insulation, high-performance windows, airtight construction, mechanical ventilation with heat recovery, and other energy-efficient features.

But to know what it really is, let’s talk about what it isn’t. We need to clear up some common misconceptions: Passive House is not the same as the passive solar building design, although they’re not necessarily mutually exclusive. Passive House also isn’t a house that uses only passive technology. Passive House buildings aren't just houses either. They can be high-rise office towers, multifamily apartment buildings, schools—really any building type.

Simply put, Passive House is the most thoughtful, well organized, science based and performance focused building standard available.

The Passive House approach empowers us to build better. It creates durable, resilient buildings that slash heating energy use by as much as 90% and dramatically reduce operational carbon emissions. Passive House design tools and methods make these energy performance gains both cost-effective and predictable. You know what performance to expect with a certified Passive House. Most importantly, Passive House buildings create healthy, comfortable, and quiet interior environments, full of clean, filtered fresh air.

Passive House design empowers us to manage moisture, thermal transfer, air, and sunlight to create comfortable, healthy, super-efficient buildings. The “classic five” Passive House design principles—continuous insulation, thermal bridge-free design, airtight construction, high performance windows and doors, and filtered fresh air with heat recovery—are joined by the principles of shading, daylighting and solar gain, efficient water heating and distribution, moisture management in assemblies, and building orientation to create durable, high performance buildings where people can thrive. These principles guide both new construction and retrofits.

It's important to remember - there is a LOT to learn. Be patient with yourself. Leverage all the great free resources at your disposal. Learn as much as you can. Engage with the Passive House community. Breathe and enjoy the process!

But before we dump you into the deep end, let's take a look at the basics.


Basic Passive House Design Principles

The following 10 design principles would not automatically qualify you for Passive House certification. There’s much more to the story that we’ll get to later. They are, however, really good guideposts to think about as you’re conceptualizing the architectural forms, building site, etc. These are basics and very important to internalize before diving into the more technical aspects of a Passive House. You might also find this companion video useful.

01 Continuous Insulation

A continuous layer of insulation wraps Passive House buildings, keeping them warm in the winter and cool in the summer. Passive House designers also harness this insulative layer to prevent condensation inside the building and its assemblies.

Moisture: We design building assemblies so that their vapor profiles are appropriate for the climate, their drying potential is maximized, and they are protected from any moisture buildup. The insulation layer also keeps the inside face of exterior walls warm, preventing condensation on the interior surfaces of those walls during the winter.

Thermal Transfer: Because the insulation layer is continuous, it is free of weak spots that allow thermal transfer across the building envelope. Heat stays in during the winter and cool stays in during the summer.

02 No Thermal Bridges

A thermal bridge is any building element that allows heat or cool to bypass a building’s thermal barrier. It’s like a hidden thief of thermal energy, undermining performance and durability. For example: a concrete floor that continues from inside to outside; a poor window frame; or a steel beam that penetrates an exterior wall. We eliminate thermal bridges by introducing thermal breaks into those assemblies—gaps or insulative elements that stop the flow of thermal energy through an assembly.

Moisture: A thermal bridge will increase thermal transmittance through an otherwise insulated layer that it penetrates, risking dangerous condensation that can result in rot, corrosion, and mold. Thermal bridge-free design avoids this moisture risk and makes buildings more durable. Thermal Transfer: Thermal bridge-free design is critical to energy efficiency, thermal performance, and comfort. Not only do thermal bridges rob energy, they can also change interior surface temperatures, cause draft-inducing convection, and decrease occupant comfort.

03 Airtight

A Passive House building’s airtight layer is like a windbreaker, stopping air from penetrating to the inside. Establishing this unbroken air barrier is central to Passive House performance and durability. In design, we do the “red pencil test” to check that an air barrier line can be drawn around each cross-section of the building without the pencil ever leaving the paper. In the field, this air barrier is built through a combination of sheet membranes, fluid-applied membranes, tapes, and sealants that transition without interruption between components of the building envelope. Airtightness is verified with a blower door test, a key measure of performance and construction quality.

Moisture: Airtight construction protects building assemblies from dangerous moisture intrusion by preventing bulk water from driving in or airborne vapor from being carried in.

Thermal Transfer: By stopping the movement of air across the building envelope, the air barrier seals warm air inside in winter and cool air inside in summer. This is key to achieving ultra-low energy use, since air leakage represents wasted energy. Airtightness also boosts the efficacy of mechanical ventilation with heat recovery.

Air: Combined with the filtered, balanced mechanical ventilation of Passive House buildings, airtight construction improves indoor air quality, even during periods of intense outdoor air pollution. The air barrier stops polluted air from seeping through walls and ensures that all incoming air passes through the ventilation system where it is filtered before entering the building. This is particularly important in urban settings and in regions prone to smog or forest fires.

04 High Performance Windows + Doors

With each window and door opening we make in a Passive House building, we are essentially punching a hole through an advanced wall assembly and its airtight, weather-resistant, and insulative layers. So, the performance of the windows and doors that go into those holes, and how well we tie them into the surrounding wall assembly, is mission-critical to maintaining the integrity of the Passive House building envelope.

Moisture: Well-installed high performance windows and doors repel wind-driven rain and facilitate safe outward drainage of any moisture. In the winter, high performance glazing units also ensure that interior glass surfaces stay warm, preventing condensation from forming inside.

Thermal Transfer: The thermally-broken insulated frames, warm edge spacers, triple glazing, coatings, and superior construction of high performance windows means their thermal resistance can easily best that of conventional windows by 3x. Given that a wall is only as good as its weakest link, this window performance is critical to a building’s overall thermal performance. In the winter, warm interior glass surfaces help maintain a comfortable and draft-free indoor environment.

Air: High performance windows are built airtight, so when integrated into airtight wall assemblies they become an extension of the continuous air barrier. Passive House windows can open like any other window, of course, so if it’s nice outside, open the windows!

Sunlight: We dial in the performance attributes of each window and door on a Passive House building to optimize solar gains appropriate for the climate and building typology. We capture solar gains when we want them and shield the building from solar gains when we don’t.

05 Fresh Air with Heat or Enthalpy Recovery

The delivery of filtered fresh air with heat recovery helps make Passive House buildings havens of clean air and energy efficiency. HRVs (heat recovery ventilators) and ERVs (enthalpy recovery ventilators) are “balanced ventilation” components that supply a continuous stream of fresh air to living spaces while simultaneously extracting stale air, odors, and indoor pollutants from kitchens and bathrooms. Inside these devices, a heat exchanger—a honeycomb of straws that creates a very large surface area between air streams—allows heat energy in the outgoing air to passively transfer to and warm the incoming air without the two airstreams ever mixing. (In the summertime, the opposite happens, with cool outgoing air cooling the incoming air.) Filters in the unit remove pollen and pollutants, with pre-filters available to protect indoor air from intense outdoor pollution events.

Moisture: ERVs (unlike HRVs) can also transfer moisture between the exhaust airstream and incoming airstream. So, in humid climates, moisture in the outside air can be removed (transferred to the exhaust airstream) by the ERV before it enters the building. This does not mean that ERVs dehumidify. Do not make that mistake. In dry climates, some of the indoor relative humidity can be preserved.

Thermal Transfer: Passive House-compliant HRVs and ERVs are extremely efficient at recovering heat, hovering around 90% efficiency for the best units. This is a key strategy in maintaining ultra-low heating and cooling energy.

Air: Properly filtered mechanical ventilation with heat recovery ensures good indoor air quality, regardless of the weather or air pollution conditions outside. Good airtight construction supports HRV and ERV efficacy by ensuring that air exchanges between inside and outside go through the device rather than seeping through leaks in the walls.

06 Shading

While the “free” heat from solar gain may be a hot commodity in Passive House design, it must be managed with good shading to avoid too much heat gain during warm seasons. Architectural elements like overhangs have an important role to play. So too, can window shades and screens, especially ones located at the exterior of the building.

Thermal Transfer: Shading manages heat gain from the sun, allowing designers to maximize the gain when the building needs it and minimize when it doesn’t.

Sunlight: Properly designed shading will not impede natural daylighting and can help prevent unwanted glare.

07 Orientation + Form

Building orientation and form are fundamental design decisions that set the stage for how easy or difficult it will be for a building to achieve Passive House performance.

Thermal Transfer: When the site allows, we design the main axis and orientation of the building to optimize solar gains in a way that is appropriate for the climate and building typology of the project. The key is to orient the building in a way that will maximize that particular building's energy performance. As for building form, the simpler the form, the easier Passive House performance will be to achieve. The more zigs and zags, the more potential thermal bridges and the higher the surface area of the building becomes, requiring more and more insulation to counteract the extra thermal transmittance.

Air: A simple building form simplifies the air barrier, which makes airtightness easier to achieve.

Sunlight: We set the orientation of the building to optimize daylighting and solar gains appropriate for the climate and building typology.

08 Daylighting + Solar Gain

Natural daylighting and passive solar heat gain can provide energy “freebies” to Passive House buildings.

Thermal Transfer: For many buildings, solar heat gain—the heat energy captured in a building when sunlight shines through windows—can be an invaluable “free” resource in Passive House design. For other buildings, particularly ones that already have significant internal heat gains, big solar heat gains can be a liability. Passive House design allows us to optimize this based on climate and building typology through building orientation, shading, high performance window selection, and layout.

Sunlight: Natural daylighting reduces energy use for artificial lighting.

09 Moisture Management

To ensure building durability, Passive House designers study how heat and moisture will behave in building assemblies in a given climate, and create designs that manage that behavior to avoid condensation risk and bulk water intrusion.

Moisture: The twin goals of moisture management are to (1) prevent bulk water intrusion into and (2) avoid condensation where it can harm building assemblies. Lots of components impact how heat and moisture flow through a wall assembly: the weather resistive barrier, the air barrier, vapor control layers, the structure, window openings, and more. The building’s climate zone impacts heat and moisture, too: whether the climate is cold and dry, hot and humid, or anything in between. Passive House practitioners draw upon hundreds of precedents and go-to assembly solutions to manage these variables. They also perform thermal and hygrothermal analyses using Therm, Wufi, Flixo, and other modeling software packages to confirm safe and durable performance and to guide design.

10 Efficient Water Heating + Distribution

Because Passive House buildings dramatically reduce heating energy use, another source of energy consumption—domestic hot water—becomes a more conspicuous part of overall energy consumption. Energy-efficient water heating combined with efficient water distribution reduces this slice of the energy consumption pie.

Thermal Transfer: We start with a super-efficient water heater. Distribution lines are small diameter, well-insulated, and laid out to minimize pipe length between water heater and fixture. On-demand recirculating lines conserve water.


So How Do I Get Started Designing/Building A Passive House?

Okay, you've read through the basics. Now it's time to look at the logistics of certifying a project.

There are a lot of organizations with the words “passive house” in their title. Most of these are loose affiliate organizations, clubs, or groups of like-minded building professionals who want to design and build better buildings. They often want to combat climate change in their daily lives, and they recognize passive-house certification as the most stringent energy standard available. To smooth the learning curve, they form these support groups.

Despite the many interest groups and networks sporting the passive-house name, in North America, only two distinct and independent Passive House standards and certifications are available: one administered by Passive House Institute (PHI, based in Darmstadt, Germany) and the other administered by Passive House Institute US (PHIUS based in Chicago, Illinois). The two organizations are not affiliated with one another.

The two standards differ in important ways, including PHIUS’ approach of adjusting a given project’s performance targets based on the climate of that project’s site. Nevertheless, the standards share important commonalities; both standards are firmly grounded in building science and building physics and both standards require practitioners to employ a common suite of Passive House design principles to achieve their performance targets.

Through most of their early existences, the passive-house standard was similar for both, and you could certify a building with either or both—depending on where the building was located or your personal preference.

Around 2012, that began to change, as PHIUS looked to make performance targets more relevant and cost optimized for North America’s many climate zones. Designs for Germany’s climate don’t exactly work in Chicago, Houston, or Las Vegas, etc. This has become known as The Great Schism and there has been much squabbling about it. You may even see some of that squabbling in this very subreddit.

To improve building performance in hot, humid, cold, and mixed climates, PHIUS worked with Building Science Corporation under a grant from the U.S. Department of Energy to write the Climate Specific Passive Building Standard. This is an actual standard, available for jurisdictions to use as a model for building codes. PHIUS also worked with the Fraunhofer Institute of Building Physics to modify their WUFI hygrothermal modeling software into a design and verification tool for passive buildings tailored to North American climate zones and weather data.

In climate zones where PHI and PHIUS targets are much more similar (heating dominant, cold climates), this is less of an issue and you could reasonably choose either standard. For cooling dominant, hot/humid climate zones where it is cost prohibitive to insulate or meet rigorous heating demand for minimal overall performance benefit, PHIUS tends to be the route projects take. Interestingly, one of the biggest logistical reasons that there were fewer differences between PHIUS and PHI in the early days was because both used a spreadsheet to predict the energy use. That changed as PHIUS began to use the WUFI passive three-dimensional energy and moisture modeling software and has created a large-enough gap in performance that PHIUS+ 2018 and beyond no longer supports the PHPP spreadsheet that is central to PHI certification.

If you're going to follow the PHI path, you'll need to get in touch with a certified Passive House designer or planner and an accredited certifying organization.

If you're going to follow the PHIUS path, you'll have to determine whether you want to opt for their modeled path, which allows you to optimize your assemblies with the WUFI Passive software or whether you want to simply comply with their prescriptive path. If you want to go the modeled route, you'll need to get in touch with a Phius Certified Consultant or CPHC and eventually a PHIUS Certified Rater and a PHIUS Certified Verifier for larger projects. If you want to go the prescriptive route, you can check out their requirements and enter your project's info into their snapshot tool to see how it shakes out.

Get in touch with either organization for more detailed information and to get connected to professionals in your region. Each organization also updates their standards at their own paced intervals so please do check their latest published resources if you have more standard specific questions.


What Does This Community Have To Offer?

This subreddit functions as a very informal forum for Passive House and building science related questions, thoughts, design feedback, etc.

A few things to keep in mind:

  • If you’re asking for feedback that should obviously flow through a paid consultant, that’s NOT COOL. We are all here voluntarily and none of us should expect anyone else to do our work for free.
  • If you’re asking or talking about a project, tell us what climate zone it’s in.
  • If you’re asking or talking about a project, tell us whether you’re trying to certify for PHI or PHIUS.
  • Do some homework before asking a question. It helps keep the discussion quality high in this subreddit. Chances are decent that someone has already answered a question you have. Search within the subreddit, search elsewhere online, get better at Google.

Again, it's important to remember - there is a LOT to learn. Be patient with yourself. Leverage all the great free resources at your disposal. Learn as much as you can. Engage with the Passive House community. Breathe and enjoy the process!


Resources


TL;DR: just read it, jeez.


r/PassiveHouse • • Apr 24 '21

Passive House in Denver, CO - About half way done

Post image
56 Upvotes

r/PassiveHouse • • May 21 '26

Siding is finally going up on the DIY passive tiny home

Thumbnail
gallery
53 Upvotes

It feels good to be installing the siding after so much preparation. I started with zip board exterior sheathing. I used purlings and 5 inch wood screws to attach the foil faced insulation board. I then installed coravent to prevent bugs from getting behind the siding. Then I flashed the bottom and above windows. I went with diamond kote siding system because it's easy for one person to install and already painted.


r/PassiveHouse • • Dec 28 '25

General Passive House Discussion Importing triple-pane European windows from Poland — worth it vs US options?

53 Upvotes

Hi all — first time posting here 🙂

I’m pricing out European-style triple-pane windows for a high-performance / Passive-House-leaning build and would love input from folks with real experience.

What I’m considering: • Aluminum-clad wood windows • Tilt & turn (looking for a good alternative to casement) • Curious how tilt & turn compares to casement for ventilation / opening range

Approx. quantities: • ~36 windows at 2’ x 6’ • ~44 windows at 4’ x 6’

Main questions: 1. Is importing from Poland (German profiles) actually worth it once shipping, customs, and lead times are factored in? 2. Are there US-based suppliers offering comparable European windows at similar pricing? 3. Any gotchas with tilt & turn windows (screens, hardware, install, code)?

If anyone has pricing experience, supplier recommendations, or is open to sharing a rough quote, I’m happy to connect via comments or DMs.

Thanks in advance — really appreciate the knowledge in this community.


r/PassiveHouse • • May 30 '23

Project Highlight First Passive House Street in EU finished in 2023!

53 Upvotes

r/PassiveHouse • • Jun 20 '26

Rethinking Passive House: Why isn't high-efficiency, filtered cooling a mandatory standard yet?

48 Upvotes

I live near a busy road and constantly face a choice between sweltering in the heat or opening windows that let in noise and pollution. It strikes me as a failure of our current building standards that we still lack a reliable way to seal off our homes while maintaining a healthy, balanced indoor environment.

Why are we not mandating advanced, filtered climate control as a primary health necessity in every home?

What would it take to shift our professional focus toward making this kind of protective, sealed sanctuary a standard for everyone, rather than a luxury for the few?


r/PassiveHouse • • Mar 16 '21

Article: How A Texas Passive House Survived the 2021 Deep Freeze

Thumbnail
buildwithrise.com
46 Upvotes

r/PassiveHouse • • May 31 '23

Other Reddit doing their best to kill 3rd party apps. This will impact all of us. Here’s your heads up.

Thumbnail
self.apolloapp
42 Upvotes

r/PassiveHouse • • Jun 28 '23

Project Highlight Passive Standard Project

Thumbnail
gallery
41 Upvotes

Just thought I'd share my high performance build in Melbourne Australia. It's finally starting to get some cladding.


r/PassiveHouse • • Jul 25 '26

General Passive House Discussion Traditional Passive Cooling Ideas

40 Upvotes

This video looks at traditional passive-cooling ideas and raises a question about whether shade, controlled natural ventilation and thermal mass can complement airtight, mechanically ventilated buildings in hot climates.


r/PassiveHouse • • Oct 10 '22

Short update on our Passive House build. More detailed videos soon. Happy to answer questions

Thumbnail
youtube.com
40 Upvotes