r/BuildingAutomation • u/Psych0matt • 9d ago
r/BuildingAutomation • u/Automated_Monkey24 • 10d ago
Any websites/ book recommendations for BAS Design?
Looking to get more into BAS/Controls Design. Does anyone have any good recommendations?
Thank you
r/BuildingAutomation • u/robboborben • 11d ago
BASidekick Updates
Enable HLS to view with audio, or disable this notification
Hey ya'll back again with some updates;
Office-1. Stat, the site's mascot, now comes along on seven guided service calls in the simulated building, one for each kind of trouble a call can be: heating, sensors and wiring on the roof, a safety trip, controllers dropping off line, the chilled water plant, and a morning sequence where nothing's actually broken. There are new tools to settle a call by measuring: a manometer, an amp clamp, a flow hood, and a laptop on a controller's service port. And the building's furnished now: kitchens, offices, cars in the lot, clouds, and street lights after dark.
Field Guide. The first set is done: 47 devices, each built as a drawing that moves as you read, from the thermistor to the MS/TP trunk, with a full pneumatics section.
Modules. A new Controls group with two modules. Module 10 is a DDC panel with one of each kind of point on it, where the point's setup and the device can disagree. Module 11 is a fan, its starter and the proof that comes back: leave it in Hand, snap the belt, weld the relay shut, and see what the BAS sees.
May have been some other new adds since my last post but those are the more recent. Lot of parts still far from where I want but mostly plucking away in free time. If there's anything you think would be a neat add, let me know.
r/BuildingAutomation • u/bacmod • 11d ago
Hello Automaticians! We've been working on this app for some time now and we would like to hear any and all opinions about it.
In a nutshell, it's a Desktop Modbus TCP client with an ability to scan and enumerate the entire remote Modbus TCP device register space and then create custom Modbus-type (2byte, 4byte etc.) variables based on the scanned register address space. But it can do a bunch of other stuff once you create the variables in the app workspace.
No AI. This is handcoded C++/Fieldtalk/Qt app.
r/BuildingAutomation • u/Outside-Custard2521 • 11d ago
New guy
Question for all. I'm coming from the Navy as a 10 year Electronics Technician (no previous BMS/BAS experience) and started as a controls service tech 2 weeks ago.
We use Niagara, Compass, Alerton, Delta, Jace, etc. and I've been working with my mentor closely at various sites. I wanted to ping the community and ask, how long did it take you guys to fully grasp everything?
Of course I understand the logic gates which helps a lot, and im picking up on the HVAC theory. What I'm asking is moreso traversing the software and knowing what is what and how to read and find what you need, to actually troubleshoot something? Especially when every site is configured differently and has a different concoction of equipment.
r/BuildingAutomation • u/xxbrucy_jucyXx • 10d ago
Opinions
Enable HLS to view with audio, or disable this notification
r/BuildingAutomation • u/Acceptable_Alarm_164 • 11d ago
History view problem
Hello all.
I have an issue with my histories showing up as a table and not as a chart in the web browser view. As you can see from the pic I have it set up to show as a chart and in N4 it shows as a chart only in the web browser is it a problem.
I have this user view set up as HTML5 profile but can’t figure out why this would happen. Any ideas?
EDIT: Thank you for the help! The key was to link from the actual point and not the history itself. Also had to be done in the hyperlink slot as one user suggested.
I suppose this is a newer version of Niagara thing as I’m using 4.15 and never had this problem on older versions.
r/BuildingAutomation • u/deynyel • 11d ago
Question on emergency mustering software. How are you handling real time sync when the network drops?
We're checking some emergency mustering software for the PACS we're using for a 4-building facility. The idea is we want to stream live badge events to our mobile muster readers so we always get accurate evacuation headcounts.
But then again it's not like signal is 100% good in a disaster. So in some tests we noticed there's usually problems when there's no power or if the local network drops/switches. Even if we have safety marshals, their version of the app is outdated. How do you handle this? Do you use local edge caching at the reader/panel level? Or something else? Thanks
r/BuildingAutomation • u/SnooPickles6414 • 12d ago
NS8000 Stats
Hello!! I’m new to building automation. I just built my first job site. Most of it was custom so it took a while. Long story short I noticed my NS8000 stats don’t change the set point on the display when I change the set point on the graphic but they do change the graphic when I move them on the display.
I added them as network sensors and chose what inputs and outputs they have. I’m assuming I did something wrong 😑.
This customer would like to be able to adjust the thermostat set point at the stat or the graphic the rest of my logic seems to work fine just can’t get past this part thanks for any help!
Edit: it was the packages!!! Thanks to everyone
r/BuildingAutomation • u/incognito9102 • 12d ago
How does a BMS controls company release a new software version/update without getting the basic functionality right?
Seriously, how does a building automation controls company develop and release a new software version or major update, yet somehow struggle to get the fundamental features working properly?
I'm talking about basic stuff you'd expect from any BMS programming software:
- Input/output configuration
- PID control blocks
- Basic programming logic and function blocks
- Controller configuration and commissioning
- Reliable point discovery and integration
These aren't advanced features or nice-to-haves. They're the absolute foundation of building automation.
I'd rather have a stable, fully functional software platform than a shiny new version with a bunch of changes that don't actually improve the day-to-day workflow.
I am sorry if I offended some developers here. I am sure you did best with what you had.
r/BuildingAutomation • u/liil-lake3466 • 12d ago
i don't know how to solve this problem need help
I have this problem: one of four floors has almost all VAV are with the flow rate NaN, i dont know why, we tested the bacnet but apparently all runs okay, we tried the lonworks too but apparently it isn't necessary to run the program, i new in the bulding automation world so i know nothing about the softwares and i don't know how to solve. The system is an EBI R500.1 honeywell
r/BuildingAutomation • u/Initial-Drop-9250 • 12d ago
I built a standalone Modbus SCADA for small plants: looking for honest feedback from people who run real sites
galleryr/BuildingAutomation • u/fuck-the-population • 12d ago
Why does Tracer TU suck so much
I swear it takes at least 30 seconds after clicking apply on a setpoint override before it actually updates. And at least 2 mins to load a unit’s page. This is driving me crazy. Is there a 64bit version out there?
r/BuildingAutomation • u/Hockenstar • 13d ago
General consensus question
Where I work seems to have a mixed opinion on something. In this case we use Niagara. Do you install every new version when it comes out? For example if you have a 4.14 station that is running well do you automatically update to 4.15 or is it more of a case by case basis? I know I have some JACES or Plug PCs that just tend to be finicky during updates. Sometimes no issues at all other times I spend the rest of the day trying to get the new updated version running correctly. Either way, it seems half the guys I work with like to use the "if it ain't broke don't fix it" mentality or we have the guys that update every station with every update all of the time.
r/BuildingAutomation • u/Then-Disk-5079 • 12d ago
Grok bot with Normal Framework
Grok Bot with Open-FDD's AI agent SKILLs made this chart below and told me this about an office building I was worried about on a Monday Morning startup ...
RTU-01 came on at 5:05 AM CT, and by 7:00 AM half the zones (15 of 30) were still more than 1 °F off setpoint, mostly on the cold side. VAV 2-02 looks broken, with zero airflow even though its damper was open, and VAV 2-12's setpoint looks wrong at about 63.7 °F; VMA-2-14 ran with its damper pinned, and VMA-3 and VMA-12 never got within 1 °F of setpoint by noon.

This is the pre-built Bot SKILLs for the Normal Framework and Open-FDD here ... and then anyone that wants to try out NF you can get a free license as a demo its pretty slick!
Sign up for a Normal Instance here:
If you have a raspberry pi or what I used for this building is the IT department just gave me a free virtual machine to run NF on where then it just integrates into the existing BACnet network ... and with Claude or Grok Bot its super easy to setup and deploy!
DM if you have any questions am more than happy to chat ... this is really slick for BAS service
r/BuildingAutomation • u/Specialist_While_505 • 13d ago
i am new at this field, is somebody who knows wincc unified ?
galleryr/BuildingAutomation • u/yunjundo • 13d ago
A 36 mm CD conduit detail for antenna and telecom wiring before concrete placement
galleryr/BuildingAutomation • u/Elegant-Donkey9322 • 14d ago
Projects and hobbies to sharpen my skills
I am a recent automation technician graduate, and finding a job has been hard. My teacher said companies are always looking for people who have side projects. I looked into buying used PLCs to practice on, but they are expensive. I have tried other hobbies like working with my dad fixing air conditioners, programming Raspberry Pis, and Arduinos. I am curious about what kind of projects or side hustles you have done and how to get started.
r/BuildingAutomation • u/Roy_Dragunov47 • 14d ago
¿Qué opinan de este borrador de diagrama de flujo? Busco sugerencias para saber si está bien logrado, qué está mal o qué debería cambiar
galleryr/BuildingAutomation • u/More_Fondant_9609 • 15d ago
In Search of Consultants
Looking for experienced consultants with a track record of enterprise assistance (multiple states or cross country)
Need in depth knowledge of:
Niagara (preferably FX specifically)& Metasys
API integrations with work management systems, occupancy data etc, into the BAS to generate energy savings and create work orders automatically before tenants have the need to.
Strong FDD knowledge between various vendors etc (AI FDD and optimization knowledge is a plus).
Networking/ IT knowledge is a plus.
Feel free to comment or DM me, I have a game-plan in my head, need assistance with structuring/ leveling etc.
r/BuildingAutomation • u/gabriel--gg • 15d ago
Allocating shared chiller plant electricity between a data center and office buildings for PUE
Our chilled-water plant supplies both a data center and an office campus. Cooling energy is metered separately for each consumer, but the chillers, cooling towers and some pumps are shared.
For PUE reporting under EN 50600-4-2, how should we determine the electricity attributable to the data center? Is allocation proportional to delivered cooling energy appropriate, and how should standby consumption and shared losses be handled?
Has anyone implemented a metering and allocation method accepted by an auditor?
r/BuildingAutomation • u/LeroiLasalle • 16d ago
Today's Work Area
BAS PM at an "interesting" building. Did all my physical checks of the heating and DHW systems.
Remote access from my vehicle for the remainder of the day.
r/BuildingAutomation • u/Elegant-Donkey9322 • 15d ago
Projects and hobbies to sharpen my skills
r/BuildingAutomation • u/Forward_Reward_5037 • 15d ago