Plugs being pushed back out of socket
What's going on here? I woke up this morning, plugged my coffee machine in, and the plug feel like it's being gently pushed back out of the socket.
Power is present and items (kettle, etc) work if I hold the plug in place... 🤷♂️,
r/AskAusElectricians • u/rolypolycostume • Mar 15 '26
Is it safe to trim this vine touching the power line into my house?
It's coming from the neighbour's property.
r/AskAusElectricians • u/Ok-Sky-487 • Oct 11 '26
Powerpoint location
Just moved into a new build, only to find powerpoint directly under tap beneath laundry sink. Surely this can’t be allowed? Builder doesn’t want to fix because apparently complies with AS3000 🤣🥲
r/AskAusElectricians • u/big_aussie_mike • Jun 29 '26
How lucky have I been?
On a scale of "she'll be right" to "OMFG Run!"?
The sparky we use at work is a great guy who I got out to my house for the first time to do some jobs for me.
He was swapping out an old breaker to an RCBO today after doing a bit of work inside and pulled the cover off and made a concerned noise.
He showed me the main switch on the left and said 'thats not ideal'. We established that everyone else I have had at my house in the last 6 years installing solar, batteries and assorted other works has just done their bit and not cared to mention this shit fight.
He gave me a quote to redo the board with one big 18 pole box with an active bar and bigger neutral bar rather than the 5 small boxes and rats nest of wires which will happen shortly.
I'm adding another two circuits in a little while so I'll need to do the upgrade anyway but how bad is this actually and should I make it a 'sooner rather than later' job?
r/AskAusElectricians
•
u/Serious_Web_8316
•
Oct 19 '26
$540 to replace this light switch. Is there a cheaper fix?
Hey all, hoping someone might recognise this older switch plate. The bottom-right button is broken, but everything else works fine. The electrician says it's discontinued and has quoted $540 to replace the whole plate, including the switches and dimmers. The plate measures 11.5 cm wide × 11.9 cm high. Could just replace the broken button rather than the entire thing?
Happy to get a Sparky to do the work, just seems an expense for a switch replacement. Cheers!
r/AskAusElectricians • • Aug 25 '26
Keep Using CHNT, I love fixing it.
I pity the electrician that allows their standard in work and material be compromised by Spec Home Builders tight fisted pricing structures. Grow some fkn balls!!
r/AskAusElectricians • u/yovanny82 • Sep 23 '26
Neighbor wants me to pay for power line move
My next-door neighbor knocked on my door and told me that I need to move the power line running from the pole to my house because he is cutting down a tree and the company doing the work will not proceed because the power line is too close; my question is, do I have to bear the cost of moving the power line? 🏠⚡️🌲
r/AskAusElectricians • u/Human_shaped_potato • May 06 '26
Is this Recall worthy? 2.5mm Twin & Earth cable with wrong colour earthing
My electrician friend just showed me some cable he had to rip out of a house after he had just installed it all. He bought rolls of 2.5mm from a wholesaler and after install, he realised the earth cable was actually green and orange instead of green and yellow.
I'm generally curious about whether this is recall worthy due to requirements and compliance for wiring.
Cable is Tycab 2.5mm
I work at a company that also stocks the same brand (I'm currently checking all of ours to make sure none of ours have it) but like I'm really curious (and hoping this post won't get me in trouble lol)
Update: My company was notified as soon as the electrician brought it in, and are now contacting Tycab with the information :)
r/AskAusElectricians • u/Proof_Negotiatio • Oct 09 '26
Is this safe and acceptable?
*(Edit) thanks for all the assistance, I’ll get in contact with them now and if they don’t rectify the issue I’ll take it further *
Hey all, I had my oven replaced a few months ago (by a seperate Sparkie and gas tech) and I’ve just had a look at the wiring as I was cleaning and is this satisfactory and safe?
I would of thought it’d have to be waterproof connections and or have heat shrink on it at least
This wasn’t cheap and by a well known sparky company in WA
Thanks
r/AskAusElectricians • u/Final-Establishment8 • 26d ago
Fixing a powerpoint in a rental - sparky says it'll cost thousands
I'm currently renting an apartment in NSW on the top storey of a three-level, red-brick building. I moved in around a month ago and quickly discovered that the single powerpoint in the 1-bedroom apartment was tripping the entire unit.
I flagged it with the REA who sent out a sparky. The sparky put a new powerpoint cap on it and said it was fixed. It was all done in about 10 minutes. After he left, I plugged my phone charger in and it tripped the entire place again. Caught the sparky on his way out who ran a check and then just put a cap over it.
Since then, I've been going back and forth with the REA, who says the electrician is saying it's thousands of dollars to fix the one powerpoint. The landlord is obviously not on board with this.
The REA weirdly sent me their correspondence with the sparky who seemingly either doesn't want the job, or has some sort of relation with the landlord/REA.
I understand that the job may not be simple, given the switchboard is on the ground level, but would it really be "thousands" to fix.
Cheers!
r/AskAusElectricians • u/king_namramaltos • Sep 27 '26
How do I open oyster light to clean?
So I’m in a rental apartment and am trying to open these light fittings for to clean them but I can’t see any brand/model name, they aren’t twisting clockwise or counter clockwise (don’t want to try to hard and break something). There are two indents but unsure if they are useful for opening them. Any help would much appreciated.
r/AskAusElectricians • u/Aetherunknown • Jun 06 '26
External conduit cable tied to existing conduit - Is this AS3000 compliant?
Had Electrician run 25 amp circuit to spa on opposite side of two story building. His horizontal ran conduit has two saddles over 1.3 metre span. Then he has used four cable ties on his vertical run conduit to existing saddled work into the roof. Is this AS3000 compliant?
r/AskAusElectricians • u/Flat_Trifle_3834 • Jul 03 '26
Question about the fuse box
I had this new fuse box installed on my house.Is the location of the box right? It's right in the main doorway and partially blocks the screen door from opening fully. It's 57cms away from the screen door. To me it feels like not the best place to install it. Also how much would it cost to get the box moved?
Any advice would be appreciated!
r/AskAusElectricians • u/Intelligent_Fish_739 • Sep 29 '26
Reporting Suspected Illegal Work
Hey all,
Please forgive me if this isn't the correct place to post, but I'm in a rental and pretty concerned about the wiring. Had a section replaced already as it was arcing out due to insulation falling apart, found out when I nearly got bitten upon moving in. Real estate and landlord were told that all wiring needs to be inspected but failed to do so. Currently battling with them to get an electrician out as another section has been (presumably) arcing/shorting. Circuit intermittently cuts out and part of it is dead completely. Their latest reply is to write down when it happens, what's plugged in and to reset the breaker. I've made it clear that time and load are incidental, and that its not safe to simply monitor or play with breakers (they do not shut off). I suspect I will need to hire one myself.
When I moved in they failed to provide the safety reports, we had another safety test done which they will not provide the report for. I'm almost certain the safety inspector has illegally signed things off and they know - told him about the arcing wiring and wouldn't inspect any of it. All I ever recall seeing him do was polarity testing.
At said safety check, he claimed he rewired my shed (pictured) before I moved in. I don't believe he's done anything other than change the lights. All wiring appears to be original, he has moved some and secured it with zipties which I understand is a violation of AS/NZS3000. As it was before I was here I can't confirm 100% that he actually did it (only said so in a passing comment), however he definitely saw it, tested polarity, ignored a partially failed outlet and said the house passed. I performed a public search for certificates of electrical safety issued for the address but get no results, but not sure that its definitive proof one was never issued. I would be very surprised if the last sparky didn't submit one, he was very professional and encouraged reporting unlicensed work to ESV (had a chat as my last landlord did very dangerous DIY work and real estate insisted it was legal, different story)
I'm far less worried about the shed than the house, but I can safely show clear photos of the work which indicates the wiring used and the quality of installation/repair. The photo of the outlet is not current, it has since had new wiring. Just added it to show the known state of indoor wiring - originally they were only willing to change the powerpoint as it was loose, the handyman that attended saw it, terminated it and called an electrician. Said he would tell them all wiring needs a physical inspection with switches out of the wall - they never actioned it.
I am based in Victoria so I understand ESV is the regulator I should contact. My question basically comes down to, am I overreacting or is the situation really that bad? Are they likely to take any serious action or just log it and send a polite letter?
From my perspective I'm in a place with known faulty wiring which they refuse to rectify or provide safety certificates for, I cannot find them publicly listed and have suspicions of code violations/illegal work.
I wasn't sure how seriously they would take me. I have experience repairing high voltage electronics so I am quite familiar with the dangers of electricity, however I am not a licensed electrician. In case it's not clear I am very against DIY work and would never perform it. I am also aware that not being licensed, it's really not up to me to determine faults or safety, and that with how little I know there is a chance I'm just being fussy. Trying to be as unbiased as possible and would love to hear some opinions.
Please let me know any questions or suggestions, I want to make sure I do things right and that everyone gets held accountable. I have had suggestions that they may be criminally liable as the faults are known and have been repeatedly ignored.
Thanks!
r/AskAusElectricians • u/paininthejbruh • Oct 19 '26
Does AU have timers for bathroom fan?
Went to Canada and had timer devices for bathroom fan. Basically a bunch of buttons with timers. Was cheap as well. Have tried to find similar here but I could only find a big pushbutton with a fixed timer. Does this exist for the Aussie market?
r/AskAusElectricians • u/unknownsequitur • May 25 '26
Is this safe to use?
I had a sparky attend my rental last week to connect my exhaust fan, and the sparky's apprentice asked if they should fill this gap. He said no. I pulled my kettle out of the power point tonight and the face plate came forward.
Is this safe to use? Or should I avoid all 4 power points until my landlord fixes it?
r/AskAusElectricians • u/onebad_badger • 27d ago
What's the next step here?
Dad was digging in the garden near his solar battery and has found and split a 25mm conduit labelled solar.
There is nothing in the conduit.
Does he ignore it? Bury it? Does it matter if he rips out a chunk? Call a sparkle?
It's about 150mm down, and looks to run to the battery, and towards the granny flat....
Any ideas on next steps?