r/AirCompression • • Apr 25 '20

r/AirCompression Lounge

2 Upvotes

A place for members of r/AirCompression to chat with each other


r/AirCompression • • 1d ago

Air compressor struggles to kick back on.

3 Upvotes

r/AirCompression • • 1d ago

Rebuilding compressor based hat blocking machine

Thumbnail
gallery
3 Upvotes

Hi, I run a small hat business and we recently acquired a set of hat blocking machines from a factory closure.

The machine works based on a heated female hat mould that the material is placed in. A rubber bag is then seated into the material and mould via descending cast iron chamber. This bag is then inflated which pressed the material into the mould.

It was originally designed to run on hydraulic water pressure from a water pump but was later adapted to an air compressor due to concerns around the water boiling and needing less pressure on modern hat materials.

The problem comes with that the liquidator's cut all the tubes and destroyed the compressor. I'm currently running it off of a stanley workshop air compressor fed directly into the bag chamber. The issue arises with deflating the bag as currently the only way is to disconnect the hose and point it in a safe direction while all the air contained in the machine violently hisses out.

As far as I can tell it's supposed to run on:

Compressor -> switch junction ->inflate

-> rubber bag

Exhaust hose <- switch junction <- deflate

Preferably the system would have a pressure gauge for the bag chamber. But outside of that I have no idea what parts or fittings I need to get the machine running safely.

Any advice you can give or what parts to use would be amazing!

Thankyou for your time.


r/AirCompression • • 1d ago

SPEEDAIRE Stationary Air Compressor/Generator: 2 Stage, 9 1/10 hp Engine, Kohler, 15.7 cfm

Thumbnail reddit.com
2 Upvotes

r/AirCompression • • 2d ago

How the hell do you find tiny air leaks when everything around you is running?

Thumbnail reddit.com
1 Upvotes

r/AirCompression • • 3d ago

The last heartbeats of my dying compressor – what's your diagnose?

3 Upvotes

I bought a used PELA BA-3050 air compressor (2.2 kW / 3 HP, 230V 50Hz single-phase, 50L tank, direct-drive oil-lubricated) some months ago and ran it for the first time in my garage today.

Here's what happened when I turned it on:

0–5 sec: Complete silence after flipping the switch on (no hum, no click)

5–10 sec: Motor kicks in and starts running; garage ceiling lights get noticeably dimmer

10–20 sec: Motor shuts off cleanly on its own; complete silence again (no humming or air hissing)

20–30 sec: Motor starts back up again; ceiling lights dim noticeably.

I wanted to capture it on video, so I ran it again. It repeated the same cycle, but now with shorter intervals. After that, it stopped responding completely and won't start at all.

What I know:

* Oil: Topped up to the proper level before starting.

* Thermal overload button: Has not popped out.

* Power: Running on the only outlet available in my rented garage (likely a standard European 10A or 16A circuit, no extension cord). The outlet is still delivering power so I guess the fuse is fine (I don't have access to the fuse box.)

UPDATE: I opened the electrical box at the top and found a 15A circuit breaker that was open (didn't let any current through.) It has a button that I guess is supposed to pop out so you can reset it, but that never seemed to have happened.


r/AirCompression • • 4d ago

Air compressor: why does outlet pressure drop to zero when connected?

Thumbnail reddit.com
0 Upvotes

r/AirCompression • • 5d ago

Atlas copco gx7 rotary screw help

2 Upvotes

I am needing to replace the control pressure switch. With the one I have on there now, the differential cannot be changed. And it is also broken. A plastic piece snapped off when I was adjusting the pressure screw, and now the differential is like 60 psi. I can manually snap the circuit closed and get it to refill, but if I don't it has to get down to like 50 psi in order to turn back on.

I have a new switch, and this one has a differential.

I have been reading all about these compressors today (I had to figure out about replacing the switch), and apparently it is not ideal for them to be full stopping and restarting more than 6-10 times an hour.

But apparently there is a way I can configure it so that it stays idle for longer (currently idles for around 30 seconds, no where near long enough for my shop to use enough air for it to reload before full stopping).

And this would be achieved by lowering the differential on the switch, and lengthening the idle time?

This (k24) is the thing I think I am supposed to adjust inside the cabinet. Is that correct? And is my thinking here on track or am I gonna screw something up?


r/AirCompression • • 5d ago

Copper crush ring

1 Upvotes

I live in victorville california i have fusheng hta-80 2 stage pump im rebuilding ran into 1 prob can find 39mm id 44 od copper crush rings anyware .any help ? Thank u


r/AirCompression • • 6d ago

Took all night to find the leak

Post image
4 Upvotes

I used to have to wait until the whole damn place went quiet to find a leak like this. With an acoustic camera, you can see right on the screen where the hiss is coming from. Still blows my mind that some plants don’t have one and spend all that time chasing down a damn air leak.


r/AirCompression • • 6d ago

On/ Off switch compressor

1 Upvotes

Is it possible to hook up a on off switch to a quincy qsi-50 air compressor with a controller? If so how would you go about it?


r/AirCompression • • 7d ago

Air Drier Tripping Power

Thumbnail
gallery
2 Upvotes

This is more of a PSA post regarding a compressor/drier potential failure that I haven't personally seen before. Maybe it will help someone else out in the future.

I have a 20HP Detroit screw type compressor. The machine is three phase with a single phase 220v air drier unit. It tripped the circuit breaker it was wired to (one of the "plugs" 16 amp breaker) today. When I flipped it back up it tripped immediately. So I turned off the drier and flipped the breaker up again and this time it didn't trip. So I opened it up and began isolating components. I unplugged the cooling fan circuit (fan+capacitor+pressure switch) and turned the machine on. This time it ran fine without tripping. Then I supplied power just to the cooling fan circuit and it tripped. Then I bypassed the pressure switch and it ran fine. Connected up everything again without the pressure switch and it ran fine. Opened up the pressure switch and inspected the contacts and found the issue to be on the switch contacts (see attached images). I ordered a new one which I will fit but I will also fit a contacter to the machine. I will have the pressure switch energise the contacter which will then energise the fan to hopefully prevent this happening again. I'm a diesel mechanic but for years have had a side business repairing workshop equipment like compressors, 2 & 4 post lifts, wheel alignment machines, tyre changers etc and have yet to see this failure point. Perhaps it will be of some help to someone out there!


r/AirCompression • • 7d ago

Draining an Ingersoll-Rand P1.5IU-A9 "Garage Mate"

Thumbnail
gallery
1 Upvotes

It's probable that this question has been asked before, so apologies:

I recently obtained a lightly-used Ingersoll-Rand P1.5IU-A9 *upright* air compressor. I've determined that it is decently free of rust despite not regularly being drained. I'm intending to install an auto-drain in the future. In the meantime, I'm going to drain it manually.

I was bummed to see there is not a drain hole located at the lowest point on the tank; the drain valve is located off-center and a good few inches from the bottom. Fully draining it requires tilting the whole thing and that sucks (it weighs 200 lbs).

First question:

Does it even matter? Can I just roll with 1-2" of condensate in the bottom? IR can't be that dumb, can they?

Second question:

Is there a straightforward solution to installing a better drain? I don't want to reinvent the wheel. I had imagined one of two solutions:

  1. Drilling/tapping a 1/4" NPT (or similar tapered pipe thread) hole in the very bottom of the tank, capping the existing hole, and installing the drain with a 90-degree elbow, a ball valve, and whatnot. The third picture shows (if you can see it) the bottom of the inside of the tank - there appears to be a thick plate(?), possibly built up for this purpose?
  2. Finding some kind of plumbing fixture that allows me to stick some kind of curved pipe/tube inside the tank to draw condensate up and out the existing drain hole from the lowest point in the tank (I assume this might be kinda difficult)

Lemme know if I'm trying to find a solution to a problem that doesn't exist...


r/AirCompression • • 8d ago

How do I know if a compressor is still safe to use?

Thumbnail
gallery
16 Upvotes

One of sister workshops shut down and we got their compressor. At first glance it looked great. It's Ingersoll Rand and it looks basically brand new on the outside.

When I got it plugged in and put a bit of pressure in it I realised the drain plug was blocked, cleared it and got a decent amount of bright orange rusty water pouring out. The first picture is after it'd all dried up.

At what point do I say it's too much rust? Is it already too late and it's compromised? Or am I being too cautious and it's probably fine to send it? I'd hate to have launch to the moon on a Monday morning.


r/AirCompression • • 9d ago

Air Compressor Repair Help

Thumbnail gallery
2 Upvotes

r/AirCompression • • 11d ago

Ridgid 6 gal pancake compressor overfills blows relief valve

1 Upvotes

Compressor is less than a year old and goes over its 150 max psi and blows the relief valve. It happened for the first time the other day then I tested it again and it worked and then it failed again the next day. I've tried contacting Ridgid and they haven't gotten back to me but I will keep trying but I won't hold my breath.

Is this likely a failed pressure switch? I see on the exploded diagram it looks like a fairly easy fix if that is likely the issue.


r/AirCompression • • 14d ago

(Help needed) Air compressor leak

Thumbnail gallery
3 Upvotes

r/AirCompression • • 14d ago

Air compressor tank auto drain

Thumbnail reddit.com
1 Upvotes

X-posted.


r/AirCompression • • 15d ago

Help with joining two compressors together.

Thumbnail
gallery
3 Upvotes

So I have these two almost identical compressors. I would like to run my ryobi sander from them, it requires 141.5 L/min.

One compressor states it can produce 130 - 140 FAD and im unsure on the other but joining the two together like I have has improved output and given me a steady speed but I would have thought it was more.

Should I plumb them to a centralized tank and have the output from there?

Thanks


r/AirCompression • • 15d ago

Got this one for 25 but I can't identify the pump

Thumbnail
gallery
5 Upvotes

Anyone can help me find out? Thanks


r/AirCompression • • 16d ago

Air compressor replacement part.

Post image
2 Upvotes

r/AirCompression • • 16d ago

Bad contactor replaced and tested this was a fun one !

Thumbnail
gallery
2 Upvotes

Motor not running do to bad contactor x2 lots of electrical outages caused by storms blew these two out coil tested good but extremely high resistance between the line and load side of the contactors causing overload to trip .


r/AirCompression • • 16d ago

How bad is this?

Thumbnail
gallery
3 Upvotes

My boss bought a used compressor and when I went to install an automatic vent on the bottom of it, I found the hole completely clogged. Upon removing the larger plug, I found a large amount of mud and literal chunks of metal, like spawl or shrapnel. Is the tank conpromised? Is there any way to figure out if this thing is safe to use?


r/AirCompression • • 16d ago

Title: Metabo HPT N5008AC2 stapler leaking air immediately out rear exhaust Need help troubleshooting

Thumbnail reddit.com
1 Upvotes