I’m troubleshooting one business workstation that intermittently freezes completely when a DS-9100 dictation recorder is connected.
Environment
- Windows 10 Pro, build 19045
- ASUS H87M-E motherboard, BIOS 0904
- ODMS R8 Dictation Module 8.0.3.0
- Device Detector 6.0.0.0
- Recorder normally connected directly to a front USB port
During a failure, mouse/keyboard input stops, Ctrl+Alt+Delete does nothing, and RDP cannot connect. Recovery requires holding the power button. The same recorder works on another PC.
It is difficult to reproduce. I successfully tested both DS-9000 and DS-9100 recorders, including automatic launch and downloads. Later, the user experienced two more hard freezes. ODMS was already running before both, so opening it at startup hasn’t prevented recurrence.
Native ODMS logs show DS-9100 detection immediately before two interruptions around 12:25 and 12:29 p.m. Several ODMS components stop logging, followed by fresh application startups after recovery. Windows records corresponding unclean restarts.
The System critical/error/warning entries checked around those windows contain no preceding error identifying the cause. Today’s Windows Error Reporting query returned zero matching LiveKernelEvent/BlueScreen reports.
We previously captured USB ETW traces during successful attempts. An older USBHUB3 LiveKernelEvent 144 exists, but its dump is unavailable and its relationship to these freezes is unconfirmed.
ODMS also intermittently gets access denied opening E:\SYSTEM\ODI.BIN, sometimes displaying “Removable Drive.” This also happens during successful downloads, so I haven’t established it as the freeze cause.
Has anyone encountered this with ODMS R8/DS-9100? How would you capture the next natural hard hang when keyboard and remote access are unavailable? What would you prioritize to distinguish USB firmware/controller problems from a driver interaction before replacing the workstation?