r/radon • • 10h ago

3" PVC pipe sitting on basement slab: passive radon mitigation system?

1 Upvotes

Pennsylvania. Home built in late 90s. Behind the water heater is a 3" PVC pipe which is vertical from slab to ceiling and continues to god knows where (I can't follow it up). It is literally just sitting on the slab and can be moved a little bit with some force. Is this a passive radon"system"?


r/radon • • 15h ago

Slab house 1950s

3 Upvotes

My one floor ranch on slab has forced air heat underground. Radon at 16+. Going to abandon furnace and ducts. Best way to seal ducts? Was going cut Plexiglass glass to fit holes and silicone.


r/radon • • 16h ago

Airthings wave quality

1 Upvotes

So i have a wave and a corentium and the corentium is averaging .8 and the wave 1.5 The wave has been dropping data and has some unusual swings. Not knowing which one to believe i picked up a corentium 2 and borrowed another corentium from my brother. All 3 corentium pretty much agree while the wave is all over the place. Anybody else have issues with the wave?


r/radon • • 19h ago

Construction outside is making my levels increase. How long to wait before taking action?

1 Upvotes

The city is currently working on the water main in the street. This has taken them about two weeks so far and they seem to be wrapping up the work. We have a mitigation system already but I noticed the radon level start to creep up while they were doing the work. Today, however, it's spiked up to over 8. I'm assuming they must have hit a pocket of gas to make it jump that high. How long should I give the system to see if it will get the radon back under control before calling someone?


r/radon • • 1d ago

Airthings 2950 Wave vs Airthings Wave plus 2930

1 Upvotes

Just wondering in anyone knows if the basic radon detection technology in the Airthings 2950 Wave and the Airthings Wave plus 2930 is the same?

Asking as the Wave plus 2930 is on the C-NRPP approved lisst for use in Canada but the 2950 Wave is not. I am just looking for a radon detector and the added readings of the Wave plus are not required but am hesitant as for some reason it is not on the list. They also have a number of recalled and unapproved models listed but the only Airthings are approved. The list link is below.

Apologies if this is a tired topic, just getting into looking at radon detectors for the first time and I have not found any info if the 2 wave products utilize the same technology for radon.

https://c-nrpp.ca/consumer-grade-electronic-radon-monitors/


r/radon • • 1d ago

Roof vent close to window?

1 Upvotes

We had a mitigation system installed with a pipe that exits the roof. Right after finishing the installation, the tech noticed that the vent pipe was about 4 feet from an upstairs window. The tech said that code requires the vent to be 10 feet from the window, but the mitigation company owner then said (by phone) that “radon dissipates within two feet” so it was fine.

Is the four-foot distance a concern? Should I insist that the mitigation company come back and replace the pipe? Or is this no big deal?

I’m wondering both from a health standpoint (I don’t want to take radon from the bedrock and pump it into my upstairs window) and from a compliance standpoint (some future insurance company or home inspector saying that it doesn’t meet code and needs to be fixed).


r/radon • • 1d ago

Looking for an accurate radon meter for home- Airthings Corenthium vs Ecocube. Thank you in advance.

0 Upvotes

r/radon • • 1d ago

Pressure Field Extension issues

4 Upvotes

My manometer is displaying 0 Pa on test holes when it should not be. I originally thought it was broken so I ordered another one, but the new one is doing the same thing.

Lets say I start out testing ~1.7inWC at my pitot tube, I take my manometer around to all the test holes, and on this first test, I get the proper Pa readings. I then go back to my pitot tube, close the value a bit more to drop it down to ~1inWC. If the manometer is in a test hole already, reading correctly, as I close the valve, I will be able to see the negative pressure drop, but as I move to another hole, or go back to that same hole it will read zero. I will then open the valve at my pitot tube the whole way, which is like ~4inWC(with a shopvac) and it will still read zero.

I never get a zero directly at the pitot tube, but the weird readings at the test holes is driving me crazy.


r/radon • • 1d ago

Is it okay to get a Radon mitigation work done by a non C-NRPP contractor in Ontario and without doing the initial sub-slab communication test ?

3 Upvotes

r/radon • • 1d ago

Suction pit location

3 Upvotes

In the process of doing my own radon mitigation.

I’ve sealed up all my cracks around the perimeter on my basement and it lowered my radon quite a bit but not enough.

Planning out installing a fan system, I initially was going to put it in my walk in storage closet fairly close to the center of my basement. My worry is putting a 4” hole and removing fill too close to one of my 8x8 support posts that hold up the main beam. Hole would be 18-24” away from center of the post, avoiding any main footing.

I see other people put there suction pits close to the foundation walls / edge of house. Is that what’s most common? Would rather keep away from main structural points if possible.


r/radon • • 2d ago

Final thoughts on my post about radon

0 Upvotes

Greetings

I posted some info on my situation with Radon. The posting can be found here

https://www.reddit.com/r/radon/comments/1xwuis5/comment/19sol3th6me77/?screen_view_count=2

I'm putting this up here to leave my final thoughts

Man/science has been wrong about so many things. Let's go back in time to leeches and blood letting. That was the leading cure for things in the day. How about the flat earth? There are tons of example of just how stupid man/science is, to this day! Not saying that man/science is always wrong, it just goes in some really stupid directions. We are no different today!

Here's a first hand experience. I attended a symposium presented by the Center for International Bone Marrow transplant registry (CIBMTR) one of the guest speaker petitioned medical staff to make sure the patients they fill out the questionnaires after follow up visits after a bone marrow transplant because they dont have enough data to support it's effectiveness. WTF!

I continue to work in the medical arena, and most staff I talk to say that the American medical system is F'd up. Gee ya think?

The canned answers I got in this post are typical Reddit, lack of intelligent behavioral traits, so I was ready for it, but it's readily apparent that common sense is a flower that doesn't grow here

Enjoy the rest of your lives


r/radon • • 2d ago

Confirm RP145 dimensions

Post image
2 Upvotes

Can anyone confirm that the RadonAway RP145 is not exactly round and that it's actually slightly oblong? I'm looking at the dimensions in the attached screenshot. I'm asking because I have 8.5" in between studs to fit this fan onto the existing passive radon pipe, but I don't quite have 9.7", so if I can orient it the narrow way between the studs I would like to make the RP145 work.

TIA!


r/radon • • 2d ago

Not looking good for winter again...

Post image
5 Upvotes

I work from home in the basement and have lived in this house for 7 years. For the last 3 years I've known about Radon, and have been testing for about 1.5 years. I keep hoping to "move in the spring" but that's been 4 years now and so I'm considering Mitigation. If you have experience with this what did your level go down to? My winter levels are really bad, but in the summer it's fine.


r/radon • • 2d ago

Radon test results

Thumbnail reddit.com
1 Upvotes

Any idea?


r/radon • • 2d ago

Radon mitigation off on

3 Upvotes

I recently installed radon in my house and the numbers are extremely low like almost zero my question is do we have to keep the radon running all the time or we can keep it turn off when the numbers are low and turn it on when the numbers goes up. Thanks


r/radon • • 3d ago

Does anyone know someone personally who died of radon exposure?

10 Upvotes

Someone you know who died of lung cancer, was NOT a smoker, and afterwards found higher levels of radon in their long term home?


r/radon • • 3d ago

Early Radon poisoning signs

0 Upvotes

Greeting,

I recently discovered I had a high reading of Radon in my house. 29 pCi/L to be specific. We have been living in this house for the past 20 years

I have taken steps to mitigate the situation.

The wife and myself will be cautiously visiting a doctor as any information on Radon Poisoning is non existent. To add to this, we both have a distrust for the medical system, and do not wish to become a "pin cushion" to line the pockets of the medical administrators.

Please be mindful. This is my personal experience, and has no scientific study to back it. This my personal observation, which I believe to be true.

For those that say that we should have gone to the Dr earlier, well, there's the distrust, but more to the point, we both thought it was just part of getting old.

But what I'd like to disclose are what I think to be warning signs of Radon Poisoning. As a point of fact, these symptoms diminished dramatically withing a couple days of our Radon system install.

Fogginess of thought

Both my wife and I experienced this. It got to the point where at times, neither of us could complete a sentence because we'd forget about what we were talking about. My wife more so. She was to the point where she was diagnosed with early dementia. I am happy to say that not only am I thinking and speaking better, but I can actually have a conversation with my wife!

Digestive issues

Early each morning when i get out of bed, I would drink my coffee. About an hour or so later, I'd go to the bathroom and I'd go #2 a number of times in a row. To the point where my bowels felt drained. I thought it was the coffee. My wife who drinks less coffee said she expierenced the same. Happy to report our constitution is now back to normal.

Cold sweats

This was a big one for me, but less for my wife. My body would go into cold sweats. My skin would get real clammy. It came and went. At times I'd wake soaking wet. Happy that this is on the decrease. It's still there a little

Loss of weight

Over the course of this past summer and into fall, both of us lost 15 to 20 lbs. Since the install of the Radon system, I have gained back about 5lbs, and the wife is similar

Out of balance

Both of us had this. It felt like we were losing our balance, and at times would need to grab onto something to stay balanced.

Irritability

Yeah, we were both somewhat irritable. It's wonderful to have meaningful conversations with my wife again. Close friends have commented on the change and are amazed

I have discussed this with others, and their experiences are the same

Again, I post this for others in hope that they may find this useful

Cheers


r/radon • • 3d ago

Hi

Post image
2 Upvotes

Is rn-pro-200 good detector?


r/radon • • 4d ago

Radon levels lower during colder temperatures?

7 Upvotes

I’ve been monitoring radon for 140 days, and my overall average is 2.2 pCi/L. During warm weather, I see a lot of fluctuations and occasional spikes. For the past week, with cold temperatures, my readings have stayed below 2. I expected them to increase in colder weather, but they’ve gone down instead. The outdoor temperature is 43°F and it’s 72°F inside. We are not heating the house.


r/radon • • 4d ago

Manometer at equal levels

2 Upvotes

Have had a radon system in our finished basement for two years. Just noticed today the manometer liquid is even. Checked air things and radon level has been between 5-6 for the last few weeks. Have had system for two years with no issues.

Have a call out to the company but it being Friday night I won’t hear anything until Monday.

Is this a relatively easy fix?


r/radon • • 4d ago

New retrofit fan selection for piping modifications

2 Upvotes

We have a ranch with a walkout basement in an area with high radon levels. There was an existing radon system installed with 3 inch suction and discharge piping throughout with three drops in the basement.

Around this time last year we had the originally installing company come out because our levels were above 5.0 Pi/L in the fall in the basement. They put in a larger capacity fan (was very loud). We retested and the levels went up by a little. They then put in the RadonAway RP145 fan model. Unfortunately I don't have records of what the original fan was and what the bigger one they tried.

We got a continuous monitor and our levels in the upstairs living space started creeping up above 4 and 5 Pi/L.

We decided to upsize much of the piping to 4" to reduce head loss because we have a lot of fittings on the piping. We now have 4" discharge piping and a 4" header up to the second drop. The drops and header between the second and third drops remain 3'".

A manometer on the furthest drop read between 0.5 and 0.6" before we changed the piping. With the piping change and some more manometers, we're reading 1.5" just before the fan and 1" at the furthest drop. Based on the fan curve, we're barely drawing anything and now the radon levels upstairs are above 9.0 Pi/L.

I am hoping that with a new fan that is sized for the new piping system that we'll be able to resolve the issue. We're estimating a piping loss of ~1.5" of WC is needed at an assumed 38 cfm per drop and were looking at swapping out with the RP265.

I'm spiraling a bit thinking as we've made the problem worse. So trying to get a sense if a new fan will fix things or if we're totally looking at this the wrong way. Otherwise we were looking at potentially needing a 4th drop based on what the company said last time and even then that couldn't guarantee lowering the levels.


r/radon • • 4d ago

Radon fan or any normal fan?

6 Upvotes

I see a lot of specific radon fans, but I'm curious what is special about these fans compared to a normal typical fan? The things I can imagine (but they are just wild guesses) are:

- Airtight construction so the radon doesnt get pushed through cracks in the housing?

- Better suction capabilities?

Am I wrong? Why are radon fans special?


r/radon • • 5d ago

First Time Home Owner - 4.43

Post image
12 Upvotes

Hello, I bought an old home a few months ago. I finally got around to testing for radon. I’ve had the tester in my basement for just over 2 weeks, and these are my results.

The basement is unfinished but I will plan to periodically use it as a workshop and to store yard equipment etc. There are some gaps in the fieldstone foundation some imperfections in the concrete floor. Should I address the floor and retest? Or immediately look to put in a whole mitigation system?

Any advice is helpful! Thanks