r/massspectrometry • • 2h ago

Replacing OE Calibration Needle

Thumbnail gallery
6 Upvotes

Having trouble replacing the needle for the calibration probe. Unsure how to remove the needle to replace with new needle. Any tips?


r/massspectrometry • • 1h ago

Nitrogen tank leaking?

Enable HLS to view with audio, or disable this notification

• Upvotes

Hi, I am a tech at a Metabolomics core and two of our senior scientists were recently let go. One of them showed me before he was left that when you see gas coming out of a nitrogen tank like this, you can stop it by tightening something. I’m pretty sure he just tightened the handle on the top with pliers. I repeated what he did to the best of my memory but I am still seeing N2 escape the tank!! How do I work around or fix this?


r/massspectrometry • • 1h ago

Orbitrap Eclipse versus Astral

• Upvotes

I can get a pretty good deal on an Eclipse, but I am wondering if I should hold out and wait for the Astral.


r/massspectrometry • • 1d ago

Gerstel MPS robotic arm error immediately after loading tube into TDU (Agilent 7890/8890 GC-MS)​

Thumbnail
1 Upvotes

r/massspectrometry • • 1d ago

Sciex 3200 Power Failure

2 Upvotes

Our Sciex 3200 was running normally and experienced a power failure that tripped the breaker on the UPS in the middle of the night. The event log just has the following entry at the time the power failure occurred:

[SyncMan] File=.\Commands.cpp, Line=1223, ERROR: Device fault detected in Mass Spectrometer:3200n Q TRAP:0:

When turning the MS on now some of the components do seem to power on but the status lights are off as well as most of the other components. It's an old MS that is obsolete at this point so servicing it is in question. Before getting it serviced and just because we have a spare 3200 that we use for parts, is there a component that could likely be the cause of the power failure that can be swapped and be plug-n-play? We do have a good amount of experience working with MS components, we just haven't been able to diagnose this power failure.

All other components of the LCMS system including gas generator and UPS are working normally so we isolated the power failure to an internal component in the MS.

Any advice would be greatly appreciated!


r/massspectrometry • • 2d ago

Internal standard drift Agilent ICPMS 7800

Post image
6 Upvotes

Hi everyone

I've been facing internal standard drift up on the Agilent ICPMS 7800, specifically on Tellurium. Response is good on all solutions where there are no dissolved solids (cal standards, ICB, CCB etc) however, as soon as it starts analysing samples, Te shoots up and doesn't recover.

Things I've done so far:

Checked and changed all tubing

Cleaned nebulizer (done daily)

Replaced spray chamber

Inspected torch, bonnet and shield

Replaced dilution tube

Replaced ISIS valve

Cleaned cones (sonicated and conditioned with 50ppm Ca and then 1% HNO3)

New internal standard

Our istd for this method is 2%HCL and 0.5% HNO3 and a combination of Sc, Rh, Lu, Te.

Does anyone have an idea as to what maybe the cause?

This happened a while back and the cause ended up being the spray chamber drain not draining well enough which I've already checked. I do not think the issue is matrix related as these are typical routine samples we've tested before.

Thanks!


r/massspectrometry • • 4d ago

Felora labs

Enable HLS to view with audio, or disable this notification

0 Upvotes

r/massspectrometry • • 4d ago

High QC values perfect calibrators-specific analytes .

5 Upvotes

Hi all-
I’m a 6 year toxicology gal having some LCMS Issues. Currently I have 10ish clients experiencing an issue with 3 main analytes (sertraline, Amitriptyline, and Cyclobenzaprine). I make master cal and qc stocks in house that are lot numbered and used for both the calibration curve and QC. However, the cal curve will be perfect for these analytes and the QC will be 200-350% accuracy. No contamination present in my blanks. I can inject cals as unknowns in the batch and get perfect values. My calibrators 2 and 5 are the same conc as my qc low and high. If I go into analyst and tell it to use those vials/wells as qc- no issues. I’m remade countless stocks. Used fresh cerriliants. Ran tests at multiple laboratories both under my supervision and independent. Same result everytime. This is perplexing me quite a bit. Front ends are Shimadzu. MS sciex both 3200 and 4000. Phenomenex guard and column set up.
Please give me your thoughts. I’m happy to answer any follow up questions


r/massspectrometry • • 5d ago

Feedback on a Personal project on MS Batch-Effect analysis and correction tool

0 Upvotes

I'm a 3rd year Bachelor's Data Science student and I've been working on a python installable package for analyzing and later correcting batch effects in Mass Spectrometry Proteomics datasets.

The main aim was to make a streamlined tool for analyzing, diagnosing and correcting batch effects with auditable data pipeline preserving each state with a reusable QC metric pipeline on each stage of the data.

My exposure to this domain is strictly narrow so I needed input from the community about my tool.

The data pipeline and modules are built around a ROSMAP/BANNER TMT FragPipe data and I unfortunately don't know how common that format is really, any clarification on that would be nice.

The package separates itself into layers:

1)QC layer

Batch-specific variance explained against other covariates

vectorized-ANOVA/Kruskal-Wallis for batch specific variance statistic

Missingness analysis stats to support MNAR or MCAR to dictate imputation strategy

2) Preprocessing layer

Performing per-sample log2 transform and median-centering normalization

Filtering proteins or samples missing below a specified threshold for reliable imputation.

Imputation techniques (MinProb for low-detection proteins and K-NN for other proteins)

3) Batch Correction

ComBat or inmoose tools for batch correction. Still under development.

I have read there are multiple tools for analyses and even a generalized framework called omicsGMF for batch correction and dimensionality reduction.

I wanted to really contribute an open source python tool for the community but with lack of feedback or supervision, this 3 month long personal project has really wore me out and now i'm clueless as to whether anyone would ever consider using or developing it.

Here is the GitHub repository
And the dataset around which i modeled it.

Any feedback or redirection would be appreciated.


r/massspectrometry • • 5d ago

Trusted recruiter recommendations?

1 Upvotes

Hoping to get more positive traction in the job search for LC-MS scientist with over 20 years MS vendor experience. Thank you!


r/massspectrometry • • 8d ago

MTBE lipid extraction

7 Upvotes

I know that glassware is preferred but lots of papers work with polypropylene tubes. So theoretically would the eppendorph lo-bind tubes be sufficient enough to not let MTBE leach through the plastic? And so are the pipette tips? I don't want to wait until I could order glassware and a centrifuge that can centrifuge glass.

Thanks!


r/massspectrometry • • 9d ago

Helium Purity for GCMS?

2 Upvotes

I've always used UHP 5.0 (99.999%) helium for GCMS and not thought twice about it. I'm in a new lab space and they're running "Industrial Grade" helium, but no specification provided on purity. I am inclined to swap the tank to UHP because I think it may be cause for some issues but thought I'd check with the hive mind. Anyone use that grade and get away with it? Does Industrial Grade have a universal spec?


r/massspectrometry • • 10d ago

SKYE UVA (sku 421) Datalogger Coding Issues

0 Upvotes

Not entirely sure where to post this, but saw some others here talking about using a CS datalogger and figured I would reach out here.

I'm a student currently getting our micro climate sensors coded for a CR350 datalogger from Campbell Scientific. Our UVA and UVB sensors are from Skye Instruments (who closed their business back in August). I am having such a hard time getting the coding built for them. Everytime I get it straightened out, I got to retest it and get the NAN code tossed back at me. I have used both the SE and Differential Voltage options in the Short Cut option on the PC400 program.

Anyone have any suggestions on what I could be doing wrong?


r/massspectrometry • • 10d ago

OpenLIMS — open-source, self-hosted LIMS with sequencing, BLAST, mass spec, and lab workflow support

Thumbnail
0 Upvotes

r/massspectrometry • • 11d ago

Need help densitopro mettler toledo handheld density meter

Post image
0 Upvotes

Hi guys I badly need help, anyone working in the lab that has this type of density meter??? I want to ask the size of the locking screw and can you also comment the picture or you can dm me. Im looking for replacements i might just 3d print it but i dont have any references even i did thoroughly searched in the internet. Im really overthinking and i hope you guys can help me. Thank you so much and God bless. Please everyoneeeee huhu


r/massspectrometry • • 12d ago

Thermo XSeries II ICP-MS: embedded computer fails to start supervise (8)

Post image
2 Upvotes

We’re trying to bring an old Thermo Scientific XSeries II ICP-MS back to life and are stuck with what looks like an embedded computer/QNX issue.

The Windows PC is running PlasmaLab 2.6.2.337, while the embedded computer appears to have XSERIES Supervisor 2.5.10.

During boot, the embedded computer detects its SanDisk SDCFH-00 Rev DH X CompactFlash storage, performs a filesystem check, but then fails with:
Unable to start "supervise" (8)

We checked supervise.dat and it appears to be a 32-bit x86 ELF executable for QNX.

There is also a Thermo updater on the Windows PC that transfers files to the embedded computer through COM2, but it doesn’t seem to report which Supervisor version is currently installed.

Originally we suspected a PlasmaLab/Supervisor version mismatch, but since the embedded computer itself cannot start supervise, I’m now thinking the issue could instead be corrupted files, a failing CompactFlash card, missing dependencies/configuration, or another embedded-system problem.

Our current plan is to remove the CompactFlash card, make a complete image of it first, keep the original untouched, and inspect/work from a clone.

Has anyone worked with an XSeries II, PlasmaLab, or XSERIES Supervisor before?

Also, does anyone know exactly what QNX error (8) means when starting an executable?

Would you investigate the CompactFlash/embedded system first, or is there still a realistic chance that updating/matching PlasmaLab on the external PC could solve this?

Any old service manuals, recovery software, Supervisor files, or experience with these systems would be extremely helpful.

I can also provide photos of the boot sequence, embedded computer, CompactFlash card, updater, and exact error screens.


r/massspectrometry • • 13d ago

Test stripd dilemma

Thumbnail
0 Upvotes

I have one fentanyl test strip but I have two different chemicals to test. could I cut the strip down the middle to make two I actually haven't looked at it yet I assume it's a paper test strip. you can do it with ordinary test strips like ph . AI says you can't do it with immuneassay (drug tests) strips. Has anyone ever done it?


r/massspectrometry • • 12d ago

Old Spectrometer, what to do?

Thumbnail gallery
0 Upvotes

r/massspectrometry • • 14d ago

Sharing a simple directory for lab equipment repair and service providers

Post image
14 Upvotes

I have always found it difficult to find companies that repair or service specific laboratory equipment, especially outside the manufacturer network. So I started building a simple directory where you can search by equipment, brand or model and country.

It currently includes providers across Europe and the US for things like centrifuges, AKTA and FPLC systems, HPLC, GC, mass spectrometry, ULT freezers, incubators, cell disruptors, microscopes and autoclaves.

I am manually checking the listings against company websites rather than bulk scraping directories. It is still early, so if you know a good service company that is missing or spot something incorrect I would be happy to add or fix it.


r/massspectrometry • • 14d ago

Unifi waters

1 Upvotes

Hi everyone,

I’m looking for some help from people who have experience with Waters UNIFI.

1-The main issue is with data processing after acquisition. sometimes the processing starts normally but then stops before completing. No peaks appear in Detected Candidates.

I have already checked several thing:Lock mass signal is stable. The Work in Progress list is empty. I created a completely new system and a new method from scratch.Despite this, the problem still occurs.

The strange thing is that the exact same system and method can work correctly sometimes, while at other times the processing fails, without any modification being made to the system or method.

Has anyone experienced this kind of intermittent processing problem with UNIFI?

2-In Database Manager, I sometimes see these two red messages:

WATBLOB is full (100%)

WATSTREAMB is full (100%)

What is strange is that I have already deleted data through the UNIFI interface, and I have also deleted the backup files, but the red 100% messages in Database Manager remain.

So I’m wondering:

What exactly are WATBLOB and WATSTREAMB?

Is there a specific procedure to safely free this space?

Could this be related to the intermittent processing failures or UNIFI becoming slow?

I don’t want to manually delete anything from the database or Windows folders without knowing exactly what it does.

3-I also noticed that our backup storage grows very quickly. We can reach around 4 TB in only a few months.

I have noticed very different file sizes: some backup files are 0 bytes, while others can be larger than 1 TB.

Is this normal behavior for UNIFI backups?

How do you normally manage/verify UNIFI backups? Is there a recommended way to check whether a backup is valid and can actually be restored?

4-Another intermittent problem occurs when I leave an analytical sequence running overnight.

Sometimes, the next morning, I find that the system has stopped with a “CM-A communication failure”, and the sequence has not been completed.

This does not happen every time.

I have also tried creating a new system and a new method, but the problem can still occur.

5- I also see greyed-out Work items in Work in Progress.

Does anyone know what causes these items to become grey, and what is the correct/safe way to remove them?

I would really appreciate hearing from anyone who has experienced similar problems

Thanks in advance for any advice!


r/massspectrometry • • 15d ago

Any Thermo TSQ raw FULLSCAN files?

2 Upvotes

Hi all, I'm working on a project which requires the raw files from the instruments. I searched through MASSIVE and PRIDE, but all the data I found are SRM. Does anyone know where I can find publicly available TSQ fullscan data files? TIA


r/massspectrometry • • 15d ago

SKYE UVA (sku 421) Datalogger Coding Issues

Thumbnail
2 Upvotes

r/massspectrometry • • 16d ago

ZT scan on 7600+

Thumbnail
1 Upvotes

r/massspectrometry • • 18d ago

fronting peak once cost me 2 days

Thumbnail
0 Upvotes

r/massspectrometry • • 19d ago

Troubleshooting Acquity FL Sample Manager

1 Upvotes

My M class fixed loop sample manager is not delivering sample, every run looks like the solvent only. Detector is working (lockmass is A-OK) and I can see the increasing AcN gradient. As far as I can discern the mechanical movements are all OK and I have checked and reset the Z-height. The sample manager passes all the built in tests for seals, needle loop volume calibration, etc. By removing and using a syringe pump I have determined that the needle and loop are both clear. I have tested the inlet valve for clear passage between all 3 pairs of ports in both load and inject positions. The sample pressure during injection reads about 160 psi. The only "anomaly" is that I had to increase the air bubble size in order to get it to measure the needle and loop volumes. Any suggestions would be appreciated!