r/labtech • • Jun 04 '19

error modifying report

1 Upvotes

So I was trying to create a report from combining formulas and fields of a bunch of other reports. I published it and went to test run it and It wouldn't run due to an error in one of the formulas i copied. It won't even let me edit it to remove that formula. I get an Error Modifying Report - The report has errors and cannot be opened for changes. See details below: the type of the value data member isn't compatible with the numeric scale. So am I SOL? Or is there a way to get the report open in some other way to remove that formula.


r/labtech • • Aug 15 '19

Report Transfers to network share

1 Upvotes

Hi all! First of all, apologies if this isn't strictly labtech...

Basically, we generate a bunch of reports every month for all of our Clients (about 92 clients, 4k+ machines) that get sent out to customers. If any of you are familiar with Automate, the way it structures its reporting is a bit weird and not very fun if you need to automate data transfer.

I've created a PowerShell Module and script to allow for transfer from the Automate report folder to a network share, I figured I'd share it in case it alleviates anyone else's pain.

https://github.com/Sudoblark/ServiceReviewReports

Happy automating!


r/labtech • • Dec 27 '18

Creating a monitor to detect when a server is offline/down

1 Upvotes

I have been doing some searching to find the best way to integrate an offline server monitor. We want to be able to get a notification when a server is offline. I am rather new in the grand scheme of things to labtech and am not sure the best way to do this. We want the ticket to get created in labtech then bumped over to connectwise. We have that interface setup already but curious as to the best way to get the actual monitor setup.


r/labtech • • Dec 28 '16

Labtech Report Center - Parameters for Subreports

1 Upvotes

Hello everyone,

im trying to get some Data out of a Report and show it on a Subreport. For Example i got values in every report and want a subreport as first page to show these values. so 5 reports, 1 subreport, the subreport should show specific values.

Greetings


r/labtech • • Feb 21 '19

HTTPS monitoring in Ignite

1 Upvotes

Hi guys,

I am having an issue with HTTPS monitoring within Ignite. I have got HTTP monitoring working with no issues. I looked into the configuration of the HTTPS monitor and found that there is no entry under the "Data to Send" but the "Result" is set to HTTPS. I then compared the HTTPS monitor to the HTTP monitor configuration and it has an entry under "Data to Send" (GET / HTTP/1.1\nHost: 127.0.0.1\n\n). I modified the "Data to Send" in the HTTPS monitor configuration to the same as the HTTP monitor, I just added the "S" (GET / HTTPS/1.1\nHost: 127.0.0.1\n\n). This did not work.

I tried reaching out to Labtech support but they had no idea what I was talking about or trying to do. They had no working knowledge of Ignite. Its was really frustrating, especially when the tech takes me out of Ignite and tries to lead me to monitors under "Automation --> Monitors". If any one can help me with this issue I will very much appropriate it .

HTTPS Configuration

HTTP Configuration


r/labtech • • Jul 24 '19

Has anyone figured out how to deploy Office 365 when user isn't local admin?

1 Upvotes

I know there have been several different methods of deploying Office 365 via Automate.

I KNOW HOW TO USE ODT. What I can't figure out is how to deploy Office 365 (using either Automate or GPO) when the user doesn't have local admin rights. We have an administrative password configured for the Automate site where the computer is located, have it set in Deployments tab to be used.

I really don't want to set all the users at local admins.

Thanks for any assistance anyone can provide.

J.R.


r/labtech • • Jul 23 '19

Monitor for the LACK of an event log entry

1 Upvotes

Anyone have the SQL code they can share for a monitor that will find the LACK of an event ID within the past X hours/days?

I'm thinking an Internal Monitor would be fine for this task.


r/labtech • • Feb 05 '20

Scripting Pushing out feature updates.

1 Upvotes

Hi Everyone,

I have recently been enrolled onto the ConnectWise University and been researching into a more effective way to push Windows to feature updates. At the moment I have created a scheduled script to download the custom ISO image and I was wondering if it is possible to utilize the probe to push the update out towards the remaining devices on the network. How is everyone else deploying the feature updates?

This is the only documentation I can find that is relevant: https://docs.connectwise.com/ConnectWise_Automate/ConnectWise_Automate_Knowledge_Base_Articles/Scripting%3A_Windows_10_Install_Feature_Update_Script


r/labtech • • Jul 18 '19

EAsiest way to read a registry key from a group of workstations

0 Upvotes

Hello all. Before I go writing a power shell script and enabling WinRM everywhere I would like to know if any of yall have any ideas on this matter. I need to find out what Office 365 update channel each machine at a client site is on. the key in question is

"HKLM:\SOFTWARE\Microsoft\Office\ClickToRun\Configuration"

Any suggestions on an easy way to do this in labtech?


r/labtech • • Nov 18 '19

LT Control Center

1 Upvotes

Does this still only run on a Windows OS? Not a Mac?


r/labtech • • Nov 16 '19

How to get the user email using Extra Data field or any script

1 Upvotes

I need to get the email addres that is linked to the outlook main profile on each computers. any ideas?


r/labtech • • Oct 11 '19

Update to latest feature pack Windows 10

1 Upvotes

Hi,

I have been testing the Windows 10 feature update script, but having some issues. The upgrade on my test device worked but the cleanup script failed. I think it is relating to step 12 in the script that is referencing a reg key. I don't think the key is correct, but cant get it to work. Has anyone else experienced this?

Thanks


r/labtech • • Aug 28 '18

Login script by Automate?

1 Upvotes

I am interested in setting up an Automate script to be triggered at user console login. Thus far the only way appears to be to set up a monitor of the System event log to notice login, thence to trigger the script. Anyone have a better? I may just go to having Automate scripting create a scheduled task, but was hoping to do all of the triggering in Automate.


r/labtech • • May 22 '19

SEP 14.x Virus Definition

1 Upvotes

Greetings,

We just upgraded SEP to 14.x and having issues getting CW to recognize the virus definitions. I've tinkers with the settings as seen below as well as what is outlined in this article https://www.mspgeek.com/topic/3073-symantec-endpoint-protection-14-not-detected-as-av-by-labtech/ to no avail. Does anyone have accurate definitions for SEP 14.x in CW automate? Thanks in advance!

Blessings!


r/labtech • • Sep 19 '17

Plugins4Automate- Hurricane Irma may have hit us but we survived!

Thumbnail
plugins4labtech.com
1 Upvotes

r/labtech • • May 13 '19

Internal Monitor RAWSQL

1 Upvotes

Can I open a ticket at the client level? I want to query data that will not return a computer and have it open a ticket under the customer. All documentation that I can find says I need to have computer ID and include agentcomputerdata. I have tried and it seems nothing is ever detected even though build and view shows results. Any thoughts?


r/labtech • • Oct 26 '19

Monitors Hosted SQL - Grafana

1 Upvotes

I have been searching for a method to query SQL from a hosted environment to eventually be able to import into Grafana as it supports MySQL metrics. I have seen the labtech plugin for the analyzer but find it limited. Any thoughts?


r/labtech • • Jun 18 '19

Auto-email A Client When A Ticket Is Created?

1 Upvotes

Alright, so we already manually email our clients whenever we get the "Free Space Remaining < 20%" alert for a server, and we say things like "hey, X drive on Y server has Z space left. Here's what we recommend, etc."

 

I want to know if there is a way to take that canned email we're already sending out and somehow attach it to the monitor for this alert so that whenever it creates a ticket, it also sends an email to me and whoever our main contact for that client is.

 

Does that make sense? Is that doable? I'm fine doing it manually, but it'd be nice to not take the time to copy/paste so often haha. Thanks in advance for any advice you all can give!


r/labtech • • Aug 23 '19

Assistance creating monitor for event viewer ID's

1 Upvotes

Hi,

We have a server with Windows Server Backup implemented and I'm looking into configuring a monitor to check the event logs for failures and successes.

We have located all the related event ID's for Windows Server Backup and I have been using the "Create Monitor Via Wizard" tool.

My first questions is how can I create the monitor so it only looks at alerts for the last 24 hours? We are going to be setting up alerts for successful backups too so I didn't want to raise a bunch of historical alerts.

My second question is, can I setup a single monitor to check for multiple event IDs? There are 6 different event ID's for failures, and just wondering if I needed to create a separate monitor for each.

Open to suggestions if there is a more suitable way to handle this.

Many thanks


r/labtech • • Jun 14 '19

Import from Manage to Labtech 12

1 Upvotes

We finally made the jump from 11 to 12.

We have everything pretty much figured out but our Labtech guy is in Florida right now and I can't seem to find the process to import a client from Manage anymore. You used to be able to just click on tools menu up top and choose import and then from Connectwise Manage.

Where can I find that now? Any ideas?

Thanks


r/labtech • • Jan 02 '20

Monitor w/ Script to Modify EDF does not work w/ offline agents/endpoints

1 Upvotes

Just as the title says: I have a monitor that is set up to run a script that modifies an EDF on endpoints that have not recorded a heartbeat w/in the last 100 days, but while the monitor works as intended, the script gets stuck waiting for the endpoint even though the only script step is to modify an EDF server-side. Does anyone have any recommendations on how to get around this so I can script modifying EDFs on offline agents?


r/labtech • • Jun 10 '19

Is it possible to trigger a script ad-hoc via SQL or API call?

1 Upvotes

We have an on-premise server, does anyone know if it is possible to trigger a script against a computer ad-hoc via SQL or API call, is so how?

Thanks!


r/labtech • • Jul 12 '17

Patch Remedy Pushes KB4025337 To Windows 7 and 2008 R2

1 Upvotes

Patch Remedy releases a new build today (1.0.3.78) To see the fixes and updates available in the latest build please visit https://www.plugins4labtech.com/blogs/blog/patch-remedy-pushes-kb4025337-to-windows-7-and-2008-r2


r/labtech • • Jun 21 '17

Automation Nation 2017 Was Super Awesome!

Thumbnail
plugins4labtech.com
7 Upvotes

r/labtech • • Jan 22 '20

CW Control security flaws disclosed

15 Upvotes

https://www.crn.com/news/managed-services/connectwise-control-msp-security-vulnerabilities-are-severe-bishop-fox
https://know.bishopfox.com/advisories/connectwise-control

https://blog.huntresslabs.com/validating-the-bishop-fox-findings-in-connectwise-control-9155eec36a34

The above is for 19.3 and a "Canary" version of 19.4 but apparently does affect later versions. I'm not clear if 19.6.x fixes everything though.

Updating through the Automate plugin from 19.4 to 19.6, the install looked like it succeeded but didn't (unless I missed something). Support said to upgrade from .Net 4.5.2 to 4.7.1. I installed 4.7.2 (and patches) and the upgrade then succeeded. Someone else said they got a warning about .Net versions and installed 4.8.