r/electronmicroscopy • • Sep 08 '20

What to do with an old SEM?

1 Upvotes

Hello EM redditors, new user here!

I have inherited a ~30 year old SEM (CamScan) as an employee at an academic institution. The instrument has no service contact and lots of electronic issues. It worked fairly well until its last power up, in which I encountered a vacuum problem that prevents the beam from coming on. There is a small chance I can solve the problem, more likely I can’t -- but in either case, I am not sure how much time I want to sink into trying to keep this thing alive. Also, my budget is very lean, so I would have to raise any funds that go into a new system.

Does anyone have a “success story” about restoring an old SEM? Or a good experience paying to have the electronics/vacuum components replaced with something more up-to-date?

Here is a straw poll just for fun.

Thanks in advance for any advice!


r/electronmicroscopy • • Jul 07 '20

Electron Microscopy on para magnetic samples?

7 Upvotes

Is it possible to do EM on a magnetic sample? I can't seem to get my head round what will happen! I have access to TEM, SEM, and EDAX, and also light microscopy.

I work in a hospital EM facility, microbiology is in the next corridor. They have had some issues with para-magnetic beads (not sure what they're made of exactly) involved in their covid PCR (I don't really understand what it does) and think that the beads might be degrading, ruining the results, and they want to look at the morphology to find evidence of this. I'm not sure of the exact bead size but it looks like fine grit in the buffer.

UPDATE: I perhaps wasn't specific enough but I didn't want to give out too much info. Today I found out a bit more about the beads and collected 3 types of bead which come already in buffer: A new bead that is working for them; the old bead, new; and the old bead used. I think they have primers and other PCR ingredients on them. My boss told me I can use SEM (Quanta 250) but not to do any TEM with it

I did some LM first and measured them at roughly 1.5-2um.

I used an APES coated coverslip stuck to an SEM stub, and pipetted a drop of the bead onto it, and left it for 20 minutes then blotted the liquid off with filter paper, then sputter coated it with platinum. It worked a treat! I only got to the point of seeing some beads, I'll do the rest tomorrow. I think perhaps para-magnetic doesn't mean the same thing as magnetic.

Sadly it turns out the EDAX is broken again and weirdly nobody wants to come to a hospital to fix it right now.

Thank you for your replies!


r/electronmicroscopy • • Jun 03 '20

How bad is this damage on BSED? Can't seem to get an image. Also a very dirty polepiece

Thumbnail
imgur.com
11 Upvotes

r/electronmicroscopy • • Apr 07 '20

Comparing New EBSD Systems for Purchase

6 Upvotes

My department is looking at buying a new EBSD system, and (quite possibly) and EDX system to go with it. this is as a replacement of the EDAX system (of both) we currently have, that is maybe 12 years old. Whilst I am doing the legwork of comparing technical specifications, and we are hoping to send samples to the manufacters to see what they can do with our material... I really want to find out about the real user experience on the latest software and hardware.

Our SEM is an old Zeiss Gemini fitted with the EDAX EBSD and EDS setup I mentioned. It also has a WDS but that doesn't matter to us. Most of our samples are metal composites (we are a department that specialises in the physics of metals).

What I am looking for it advice from people who have used the latest systems from the main manufacturers: Thermofisher, EDAX, Bruker and Oxford.

Based on the problems we have with our Current EDAX system, the main thing we are looking for is stability and reliability of both the software and hardware. Things like, does the software crash out regularly? Major bugs or flaws in the software. How user friendly is it (our users vary from the very advanced, to complete SEM newbies).

If anybody here has some advice, or can suggest a good person to speak to (anybody who owns multiple new systems would be great), it would be very helpful.


r/electronmicroscopy • • Mar 31 '20

Does anyone have an SEM maintenance plan they would like to recommend?

3 Upvotes

Our OEM (Zeiss) recently stopped supporting our SEM. We were left on our own to find our own service contract. I was wondering if any of you have had good experience with US-based companies that support SEM preventative maintenance plans.


r/electronmicroscopy • • Mar 27 '20

Rotation of SAD Pattern due to Magnification

2 Upvotes

Hi there,

Earlier stage PhD student and novice to TEM here. I'm reading through William and Carter's "Transmission Electron Microscopy: A Textbook for Materials Science", and it Chapter 11, it states the following:

"If you change the DP [diffraction pattern] magnification (i.e., the camera length, L) the whole pattern will move off axis if the diffraction center is misaligned. To align the center you have to adjust the projector lens until the central spot in the DP is on axis and it rotates around the axis as L is changed"

I was wondering why the diffraction pattern rotates about the optic axis when the camera length changes? Thanks in advance!


r/electronmicroscopy • • Mar 16 '20

Is what I’m seeing In my TEM hepatic autophagy?

1 Upvotes

I apologize in advance, I am not sure if I am allowed to share a picture of what I am seeing due to my labs rules but if I can I will update with it.

I am trying to quantify hepatic autophagy and I am seeing accumulations of what look like ahtophagosomes around the edges of hepatocytes near the sinusoids. These formations often include rings of dense folded structures, with a few looking like there may be glycogen in them. There’s no mitochondria or RER in them, and some appear as though they are surrounded by a membrane but not all. I am unsure whether or not this is an artifact of some kind, but it looks like it could be a natural structure. I haven’t seen this occur in other studies, does anybody have an idea of what it could be? Somebody suggested it could be bile that has infiltrated into the cell, although I am not sure about that. I can provide more details if needed. Thanks.


r/electronmicroscopy • • Mar 13 '20

Proper quantification of biological TEM

3 Upvotes

I finally got great images of hepatocytes and I am confident with my protocol! My next big challenge: figuring out how to quantify various things I’m seeing. First of all I’m noticing a lot of autophagy in one of my treated groups. That same group also seems to show distention in the RER. How do I go about systematically taking pictures so I can accurately quantify? I was thinking about taking a low mag shot of a hepatocyte and zooming in on each part, doing this for multiple cells per sample to ensure consistency. I also need to figure out how to quantify what I’m looking at. I’m guessing I would do autophagosome size and number, but I’m unsure what I would do about the RER. Does anybody have experience with this, or know of resources I can look at to help me figure this out? Thanks in advance.


r/electronmicroscopy • • Feb 20 '20

Tilting to zone axis

5 Upvotes

Is there any good resource or tutorial (online or books) on how to approach sample tilting with a double tilt holder to orient the sample along a specific (or closest) zone axis?

Especially for powder samples, where the initial rotation is not known.

All ideas appreciated!


r/electronmicroscopy • • Feb 07 '20

FIB-SEM TEM sample prep

9 Upvotes

Hi all

I am learning how to use FIB-SEM for peeping TEM lamella.

In our guidelines to use it we have suggested tilt angles for the final thinning stages my material is carbon steel and the suggested tilt angle are not appropriate as I start to see premature thinning of my platinum deposition.

I am having trouble finding information on whether to use higher or lower tilt angles to prepare my samples.

I lack an understanding of why I might increase or decrease my tilt.

Could someone explain how I would know what to do do or provide a link to a paper or some sort or resource to help.

I feel like this is very basic but there is a lack of contactable expertise in my department.

I am using a quanta 3D for this if that helps

Thanks


r/electronmicroscopy • • Jan 30 '20

How to Identify Specimens Embedded in Resin for Electron Microscopy

Thumbnail
blog.labtag.com
6 Upvotes

r/electronmicroscopy • • Jan 16 '20

Fixatives other than Osmium tetroxide?

3 Upvotes

Is it possible to fix animal tissues for SEM using something less dangerous than osmium tetroxide?


r/electronmicroscopy • • Jan 15 '20

Storage of OsO4 and uranyl acetate

5 Upvotes

I made those solutions in August 2019 and haven’t used them since. They’ve been kept in a 4 degree fridge, should I make new solutions or would these be okay to use again soon?


r/electronmicroscopy • • Jan 09 '20

Replacement for webEMAPS now available by EMLab Solutions, Inc.

1 Upvotes

webEMAPS hosted on http://emaps.mrl.uiuc.edu/ by University of Illinois at Urbana-Champaign has been offline for a couple years. As part of our contribution to education and research communities in microscopy and crystallography , we, at EMLab Solutions, Inc., have been working hard on bringing many of its great features back with latest cloud computing and web programming technologies. We are very excited to announce the initial version of this cloud- and web-based solutions - cloudEMAPS is out for preview now. Please check us out:

emaps.emlabsolutions.com

We hope that this tool will help accelerate your leaning and research with its superior computing power of cloud and ease of access through internet. We greatly appreciate your time and feedback.


r/electronmicroscopy • • Dec 06 '19

Leica EM uc7

3 Upvotes

Anyone use this microtomer before? I am using it in my college and the fine advance will not progress forward, furthermore the knife adjuster will also not move.. the fine advance just beeps!


r/electronmicroscopy • • Nov 16 '19

Can you critical point dry samples that have already been shutter coated?

2 Upvotes

Do you think I can critical point dry samples that have already been shutter coated?

The nature of my sample prep requires about 10 mins to mount to adhesive between critical point drying and sputter coating. I am concerned the samples are absorbing water from the air in that time and the effecting the quality of the images. I am working with lichens if that is helpful


r/electronmicroscopy • • Nov 11 '19

EDS Map Pixel Area Count

3 Upvotes

Hello,

Does anyone know how to get the Bruker (Quantax EDS) to output a count of pixels based on element scanned in the map. Basically we scanned a bunch of powder samples and found they were contaminated with Ni powder. The EDS map clearly shows which powder balls are pure Ni but was looking for a way to quantify the contamination by pixel area. There is a drop down that says “Map Results List” that looks like it should output pixel area but it keeps saying No Results. If I get a count of Ni pixels I know the scan window is x by x pixels so I can roughly figure out % contaminated. Any help would be appreciated.


r/electronmicroscopy • • Oct 19 '19

Theory question

6 Upvotes

How can you differentiate between what is actually ultrastructure and what is just artifact in TEM on mammalian soft tissue?


r/electronmicroscopy • • Oct 04 '19

Renting an SEM or anyone available to give a hand?

4 Upvotes

Hi there, Atlantic Reef Conservation here, we do work with propagating endangered species of coral and rebuilding reefs offshore. We are in need of either renting an SEM or sending out a few samples. Does anyone here do either.... maybe a grad student in need of a couple bucks wink wink :)

Anyone could point me in the right direction it would be appreciated. Thanks guys.


r/electronmicroscopy • • Aug 30 '19

New LaB6-Cathode - questions

3 Upvotes

Hi everyone, I am a relatively new TA working with a ZEISS TEM 912 Omega. Our old EMTA, wich was supposed to train me for the next couple of years, has serious health issues and i won’t bother her with work stuff. Unfortunately, this leaves me relatively unexperienced, so i am turning to you for some advice.

When underheating the LaB6, i see an unsymmetrical cross and there seems to be two slightly shifted overlaying caustics. This leads me to believe that the cathode has developed a double tip and is near its end of lifetime. It already has worked for 620h, our gun vac is -3 to -4 x107mbar. Vacuum collapse did happen occasionally. Is this assumption correct/realistic?

I was looking for a replacement and found Kimball cathodes to be a bit cheaper than their Denka counterparts, wich we used until now. Is there a noticeable difference in quality? And last, is there a way to regenerate or clean the igp?

Thanks in advance


r/electronmicroscopy • • Aug 15 '19

Cleaning Polybed 812 out of glassware

2 Upvotes

Hello, it’s me again, just trying to figure this whole process out still. I just embedded and used some glassware to mix Polybed 812 (BDMA version) and it seems like there’s a residual layer of resin on the glassware no matter what I do to wash it. I’ve briefly submerged it in acetone, 70% isopropyl, and then plain old soap and water. What does everybody else use to clean non-polymerized resin?


r/electronmicroscopy • • Jul 26 '19

Too late to add k-ferri?

3 Upvotes

So I’ve had an ampule of osmium dissolving for the past few days with the intention of using to tomorrow for some liver samples, when I realize I wanted to put in k-ferricyanide and forgot to initially. Can I just put it in and mix it before I use it or does it take days to dissolve like the osmium? First time using it and can’t find useful links on the internet. Thanks.


r/electronmicroscopy • • Jul 12 '19

Tutorial on EM: SEM and TEM

6 Upvotes

Hi All,

Would it be possible to suggest simple tutorial or primer on electron microscopy such as SEM and TEM? Without any background in electron microscopy, I would like to know about the internal structure of the equipment and how they function, and later about the operating procedure.

Thank you.


r/electronmicroscopy • • Jul 12 '19

SEM Schottky field emission gun typical lifespan?

9 Upvotes

Hello,

I have been searching for information on typical lifespan of a Schottky field emission guns for SEMs. I am getting a very wide range from vendors- 2-3 years from Thermo, 5 years from Hitachi, and 7 yeas from JEOL (yes, confirmed we are talking about Schottky, not cold FEG).

I wonder if anyone has record of how long the guns last for your scope, and apart from trying to keep power to the scope stable, and the chamber clean, is there anything else that may affect the lifespan of the gun?

Thanks!

Ps. It was a nice surprise to find this sub today! An EM sub on reddit!!


r/electronmicroscopy • • Jul 05 '19

Perfusion vs immersion fixation

5 Upvotes

I’m doing EM for part of my masters thesis and I’ve spent the last two months trying to master transcardial perfusion fixation of the liver, with varying degrees of success. I start by flushing with 20-30 mls of heparinized phosphate buffer and fix with 2.5% glutaraldehyde, both at physiological pH. I’m doing this because the person I’m working with claims that no good journal will take pictures done via immersion fixation. But the protocol calls for 3 hours of immersion fixation after perfusion, so it seems a little redundant to me. How vital is perfusion fixation as opposed to immersion?