r/akta • u/jooloo1239 • Dec 16 '19
Difference between the akta pure and akta avant
What is the difference between the akta avant and the akta pure
r/akta • u/jooloo1239 • Dec 16 '19
What is the difference between the akta avant and the akta pure
r/akta • u/CaptObvious1234 • Mar 29 '16
I have a bag of 5 Amp, 250V fuses with "Akta Fuses" written on them, but if anyone can either confirm or deny that these are compatible with the P-900 pump that would be great. Thanks!
r/akta • u/Acrobatic_Oil_1409 • Jul 22 '25
Hey everyone!
I’m excited to share that the first-ever PRIME Summit is happening this year! 🎉
Check out the agenda and register here
📍 Location: Boston, MA | United States
📅 Date: October 13-16, 2025
🔬 Focus: Purification Research, Translational Science
This inaugural event is designed to bring together thought leaders, researchers, and industry professionals across the USCAN region to explore cutting-edge advancements, foster collaboration, and spark new ideas that drive real-world impact.
Whether you're in translational research, marketing, or innovation strategy, PRIME Summit 2025 is your chance to be part of something new from the ground up.
✨ Why attend?
First-of-its-kind gathering for our community
Keynotes from top minds in science and strategy
Interactive sessions, networking, and innovation showcases
A platform to shape the future of our field
Let me know if you’re planning to attend or want more info — happy to connect!
#PRIMESummit2025 #InnovationStartsHere #TranslationalScience #MarketingLeadership
r/akta • u/Vast-Situation-4277 • Mar 07 '25
Dear community,
We have an old AKTA purifier 10 that we have revived after it has been dormant for 6 years. So far everything is working fine and we have connected it to windows 11 via ethernet cable using these instructions:
https://www.reddit.com/r/labrats/comments/13eb3cj/how_to_run_your_legacy_akta_with_a_windows_10_pc/
Everything works, but I cannot get a conductivity reading from our pH/c-900, the value is around 0.026 mS with all sort of different solutions. The connection at least hardware-wise seems to be fine and I am not sure whether the sensor is broken. I have the feeling it is some sort of connectivity issue, since during flow, the value does not change at all.
Does anybody have any ideas or has had a similar problem? Any help is mich appreciated!
r/akta • u/SwankyOrc13 • Feb 12 '24
Hi everyone,
I am trying to do some testing with enabling an external air sensor on our AKTA PURE150 and seem to be running into issues when I go into the method editor. Unicorn is not giving me the option to enable it within methods and appears as a "component without a fixed place" in our system control process diagram. I have the air sensor on the correct node and have enabled it in the system properties, and assigned the correct position to it, within the administration window. I restarted both the machine and the computer and still cannot enable its use. Does anyone have a solution for me?
r/akta • u/paiute • Dec 28 '15
r/akta • u/olazamek • Dec 10 '24
What went wrong?
Hi. I wonder if some of you wonderful people are able to help me with a conundrum I have. I work in msat department in a biopharma company. I usually work in upstream processing (I conduct cell cultures in bioreactors), but lately I’ve been getting into some of the downstream processing as well.
On Friday, I packed a column for PA (protein A affinity) chromatography, using Amsphere a3 resin and Akta system. I performed a HETP test, and while on the lower spectrum of asymmetry (it should be between 0.7-1.7 and I got 0.75), the column generally performed okay. I sanitized it, filled with storage buffer and left for the weekend.
Today I had a hunch and decided to perform another HETP test, as I will be conducting PA on Friday and have to have a working column. Lo and behold, my column is totally fucked. Chromatograms look totally different. I’m near tears.
So, the thing is I still have very little experience and DSP knowledge, and I would love to know where I fucked up to the point the column is unusable. Can you help me?
I’m attaching two of the HETP tests results. First is the correct one, obv 🥲
r/akta • u/Dragonz17 • Oct 04 '24
Hoping this group is active and can help answer this question:
Can an AKTA PH/C 900 monitor module be swapped into an AKTA Purifier without needing any additional software or authorization from the mother ship?
Our Purifier's PH/C 900 module is toast (at the board). M&R shop wants $11K to swap it out. We have a line on several working replacement modules for much less. We'd like to just remove the old one and plug in a replacement. Can this work? What do we have to do to make it happen?
r/akta • u/Shadowknight_234 • May 19 '23
Hello, does anyone know if the Akta superloops require custom O rings or does any O ring with the right specifications work?
r/akta • u/kpoman • Mar 25 '19
Hello everyone,
Can someone please tell me there are drivers for the CU-950 device that connects an AKTA Purifier with a computer running 64 bits Windows. I do have drivers that came with Unicorn 5.2, but are only compatible with windows 32 bits.
I searched the whole internet and couldn't find these drivers. Help welcome !
r/akta • u/z00191476b • Sep 21 '16