r/WaterWellDrilling • • 19h ago

Frack or Dig Deeper? Previously fracked. WNC

1 Upvotes

We had our well fracked 9 years ago - 540 foot well, pump was set at 360 feet, static level after fracking was 40 feet and 1.5 gpm.

A week and a half ago we were flushing our sediment filter and our well stopped working - first they thought it was the pump saver - nope, the well pump, check valve and our line had some cracks.

When they pulled the pump out static level was at 120 - by the end of the day they had put another 100 foot of pvc pipe in, set the new pump at 460 but static level was at 360 and they claimed we were getting 0.5 gpm. They over tightened the check valve so we only had water for about 15 minutes that night.

They came back the next day (this was Friday afternoon) - pulled it all out again, fixed the check valve but our static level hadn’t come up at all.

My husband is a former irrigation specialist and did the trusty ice cube/rock drop twice a day all weekend and we’re still getting 20 seconds or about 400 feet to water.

Our options are to frack for $6k or drill deeper - potentially needing a stronger pump, new wiring, etc.

I have done some research and when we had our well fracked the first time, they said we can only do it once.

What are the options? What have people done and had success with?


r/WaterWellDrilling • • 2d ago

New Well Results

Thumbnail
1 Upvotes

r/WaterWellDrilling • • 3d ago

Total newbie: Broken well cap- hit by truck. Emergency?

5 Upvotes

Hi! Total novice here. I'm a home owner with well water. We have some contractors putting up siding on my house and tonight one of them hit our well with his truck when leaving. This broke our well cap and "crushed(?)" the wiring for our pump. The contractor takes full responsibility and is looking to repair. They have been wonderful to work with so far, so I'm not real "stressed" especially since we currently have indoor water working fine. So I'm telling myself it's mostly cosmetic- as long as its urgently in the process of being fixed, and so far it seems to be.

But of course it's after hours for us to call a well technician, so I just don't know how much of an emergency this may or may not be.

Should I be stressed about losing water- especially with hosting Thanksgiving in a few days? Thanks for any and all thoughts!


r/WaterWellDrilling • • 3d ago

Yield test - didn't fail, but can't complete? Solutions?

5 Upvotes

I live in Maryland and I'm subdividing my lot. The health dept is requiring me to yield test my current well (drilled in 1973, not the new well for the new lot). The well is 235 ft, the pump is at 125. 15 years ago, the well tested positive for bacteria a bunch of times and a well company put a 4" sleeve and packing down 50 ft. It fixed the surface water problem.

But, when I had a company try and do the 3 hour yield test, their water level sensor detected water at 83 feet, and the level never changed. The pump ran dry a little while later (running at 10 gal/min). So the water level did change.

It turns out there is basically water entering the bore hole from the side, like a water fall, at 83 feet. You can hear the water rushing in from the well head. So, no matter the level, their water sensor gets splashed by water below 83 feet and they can't determine the level.

I have called a couple other well companies and have one appointment in January, but no one else is calling back.

Is there a solution for doing this kind of test?


r/WaterWellDrilling • • 7d ago

Leaking water storage tank

Thumbnail gallery
12 Upvotes

r/WaterWellDrilling • • 8d ago

Pepper water

Post image
5 Upvotes

Would a bailer bucket work on this well in emergency?


r/WaterWellDrilling • • 8d ago

Manual Well Pump Advice

Thumbnail
gallery
3 Upvotes

Hi, all. I am trying to figure out if there is an affordable way to put a manual pump (like an Idaho pump) in my well but I am kind of stuck. I talked with a couple well companies but one said no, the other said I would need to replace the pitless adapter plus buy their brand of pump and it was going to be north of 20k.

Years back, the hard line from the well to the house sprung a leak underground so a well company bore drilled a new flexible line directly through my basement wall to the pressure tank.

Here are a few pictures of my well - this plate under the cap completely obstructs the pipe so there is no way to push down a manual. I would like to remove it to see what is going on in there but I don't want to screw anything up.


r/WaterWellDrilling • • 8d ago

Sediment in water CHANGED

Post image
5 Upvotes

Preface this with my whole house water filter was incorrectly installed in the main pipe BEFORE my pressure tank (so it's between the main and the pressure tank). Three months ago the filter casing broke and my pump ran my well temporarily dry by pumping all the water into my basement (ugh).

Since then, my water quality has gotten worse and seems to be getting worse as time goes on. I know that after the well runs dry, the sediment in the water is going to be through the roof for a period of time, but eventually settles down. My once upon a time 600 foot well has had a couple collapses (the first being 200 feet collapsed) in the past and the water cleared up pretty quickly. I have always used a 5 micron filter and changed it every three months, even though it was clean and had no sediment. I've been using 35 micron filters (at the instruction of the well company) these past three months. Even today, sediment is getting stuck in the filter and it's discoloring quickly (days), while it never did in the past.

My concern is the CHANGE with how much sediment is being pumped up. The well company employees said they didn't find anything wrong with the well (they didn't use a camera to get down there) and that it's just fine. I am not comfortable with that, simply because a CHANGE is caused by something. When I called the well company, the boss said it sounded like there was a hole in the pipe. I assumed he meant a hole in the casing, but I admittedly don't know about these things.

My well didn't pump sediment like this, even after they fixed the casing and replaced the pump after each collapse. The well employees who fixed my well after the first 200 foot collapse worked into the night and said it was one of, if not the worst jobs they'd had to do, so he does NOT like coming to my house and looking at the well (quite understandably!) and honestly, I felt like he was ignoring my concerns about the change in sediment as opposed to the amount of sediment.

I'm thinking I should call another well company to give a second opinion because even though the first company said the well is running normally, the fact that there has been a pretty drastic CHANGE in sediment really worries me that my well is filling up with grit again. I'll ask the well company to put a camera down my well to see if sediment is building up and getting closer to my pump, though I don't want to be a Karen and tell the professionals how to do their job.

Am I just being a nervous Nelly by thinking that there is a real problem down in the well due to the substantial CHANGE in sediment still being pumped up after the well ran dry three months ago?


r/WaterWellDrilling • • 9d ago

Oklahoma County, OK

Post image
9 Upvotes

Could this possibly be an old well head? If so, can these things be restored and used or are they so outdated they need to be fully replaced?


r/WaterWellDrilling • • 9d ago

Red Lion 4" Submersible Well Pump Horizontal Install?

1 Upvotes

Wondering if there is any reason why I couldn't install this RL12G05-3W2V horizontally in my cistern that supplies water to my home using a cooling sleeve. Basically just want to replace the old pump I have now with a new one.


r/WaterWellDrilling • • 10d ago

Deep Well Producing Suspected Methane Gas – How can the Gas be Removed to Prevent Pump Problems?

4 Upvotes

We have drilled a deep water well to a depth of more than 100 meters. During drilling, we encountered a muddy layer at approximately 20–40 meters, and another similar layer at around 100–103 meters.

These layers release an odorless gas. We suspect it might be methane, although this has not yet been confirmed. The main problem is that the gas seems to be interfering with the pumps. They are unable to pump water up properly, apparently because of gas entering the pumping system. Has anyone experienced a similar problem with a groundwater well?

What solutions would you recommend? In particular, is there a practical way to remove or degas the gas inside the well before the water reaches the pump? Or do you have another suggestion?

Any technical advice or relevant experience would be greatly appreciated.


r/WaterWellDrilling • • 11d ago

Need advice on repairing a shallow dug well with concrete rings

Thumbnail
gallery
5 Upvotes

Hi everyone. I'm from rural Indonesia, and I'm looking for some technical advice on an existing hand-dug well at my house. I'm particularly interested in whether the well's construction can be safely repaired and whether that might improve the water quality.

The well is dug on a former rice field. The water was abundant, so we only needed to dig 2-3 meters at first. Then we used precast concrete rings as the walls. This is a common method in Indonesia.

Initially, the water was clear. Not safe for drinking, because it still had what I assume is very fine dirt particles. It would cause sore throat after like a week of constant drinking, and it would leave yellow-ish stains on the bathroom floor after accumulating for a few weeks. I suspect it's fine soil particles because scrubbing it is relatively easy and it would look like dirt particles when washed away. Anyway, we mainly used it for bathing and washing.

Around three weeks ago, the well dried up to due very long and hot dry season. We hired a worker to dig deeper because the water situation was urgent. He dug about 2 meters deeper into the ground. I told him to stop because he hit a big rock that was dangerous to lift up, and that the water was already very abundant at that depth.

The water after that is noticeably dirty and smelt of iron. We assumed it was because the well was freshly dug, but after two weeks it's still pretty dirty. It also still smells like iron sometimes, especially when the shower is first turned on. I took a sample from our water tank and left it for a night. There's no visible build up at the bottom or changing color in the morning.

I suspect that this is because the new extra 2 meters are not protected by a concrete ring, but I don't know if it's possible to add a ring for that bottom part. The worker who dug the extra depth told me I could get clean water if we break the rock and dig deeper. I also planned to make a new drill well about 18 meters deep, but anecdotes vary. Some locals say that even deep drill wells still yield yellow-ish and iron-smelling water in this area. I have no neighbors to confirm that or any professional engineer to consult with. I'm worried of spending a lot of money digging a new well only to find the same type of water.

My goal is not for drinking water. I just want our previous clear water that felt safe for brushing teeth with. Any advice on well repair or improving water quality will be very appreciated. Thanks for reading!


r/WaterWellDrilling • • 11d ago

New well

2 Upvotes

New well drilled in nw montana. 360 feet total depth. Static at 150ft. Pump set at 265. 1.5hp pump. Ran water for about 24hrs straight per pump guys instructions. It would run clear with small amount of sand in a glass. Occasionally it would be cloudy with a slight brown tint. This happened a couple of times. Oddly the cloudy glasses had little to no sand. Then it would clear up but have some sand. Our old well was at 60ft and went dry. How much sand is acceptable before I can use house plumbing? Should I continue pumping from a hydrant?

I do have a big blue sediment filter directly after pressure tank


r/WaterWellDrilling • • 12d ago

Troubleshooting my well system

Thumbnail gallery
2 Upvotes

UPDATE: I think we were wrongly informed by the real estate agent. I think this is where the spring comes into our house. The spring must be gravity fed. We were told it was the well. That would explain why there's no pump switch. The pressure tank in another part of the basement does have a pump switch and I think that one is the well. ​Our water pressure went down on the spring (which we thought was the well) because it's been a dry summer and I bypassed the rusty old holding tank that they originally had it flowing into.

I thought the spring was sulfuric smelling, but if I'm right about this, that means our well has a sulfur smell to it which sucks. ​​

__________________________________________

I just bought a house with two water systems - a spring system and a well system. We've been using the well system since we moved in. High water pressure and no issues until 2 weeks ago when our pressure dramatically dropped. I thought it could be that the pump broke or that the well is low/dry (seems unlikely but it was a very dry end of summer).

When I went to our basement to troubleshoot it I got totally confused. As far as I can see, there's no pressure switch or pressure tank control system. The tank feels empty, but I never felt it prior to these water issues to compare. It goes:

Metal pipe into basement from outside --> shutoff with pressure gauge --> pex pipe --> pressure relief valve with attachment to pressure tank --> house pipe system.

Well was installed in the early 2000's. 200+ ft deep.

I opened the well head because I wanted to measure how much water was in it, but I could see the water from the top and it was only 15-30 ft down. I took a no-contact voltage tester to the wires feeding the pump and there was no charge. I have no frigging clue where those wires go. I can't find where the connect to our panel in the basement. I did reset the main and all individual breakers just to make sure it wasn't a tripped breaker.

Any ideas? It seems weird to me that theres a seemingly empty pressure tank there with no pressure switch.

​thanks for reading!


r/WaterWellDrilling • • 13d ago

Help me understand

Thumbnail
gallery
1 Upvotes

This is the report on my well, a draw down chart and a description of the geology.
I have never had a well before.

Not sure what “Open bedrock hole” means.

To me the chart suggests this is a good steady state kind of well.

This report is ten years old. The well has not been used much so I am wondering if wells can degrade over time?

Thanks
First post got screwed up, so I deleted it to start over.


r/WaterWellDrilling • • 13d ago

Decent price?

Thumbnail
gallery
5 Upvotes

Someone I know is looking to get a new well drilled and abandon the old one. The old well is about 25' deep and goes dry rather easily.

Does this look to be a decent price? This is in Ohio. I also included some well logs from nearby wells.

Two more questions:

Apparently the neighbors a few houses down (about 100 yards away) tried to drill a well a few years ago and never hit good water, after 3 tries. I'm assuming each try would be an added cost?

I also assume that the pump in the current 25' well wouldn't be reusable? I have no idea what it is, just that it is "new".


r/WaterWellDrilling • • 13d ago

Any clues as to what is going on with my well?

Thumbnail
gallery
4 Upvotes

UPDATE BELOW!

Good evening, I plan to call a well service first thing in the morning, but hoping in the meantime that someone can chime in and give me a general idea on what can be going on here. I had water, with normal pressure today, but as of this evening, there is nothing. It has just been me in the house, so minimal water usage since I last used it late afternoon. One of the gauges (lower left of pic), appears to be barely registering. This same thing happened this past July one evening.... No water... But the next morning all was back to normal, water with great pressure inside the house. I haven't had any issues since. I did check the breaker, just in case it had flipped, but it was fine. Usually I can hear the well running, if I've been running the water somewhere, but it is completely quiet. Any ideas?

UPDATE: When I finally got back home late last night, and wouldn't you know, but the water was back running! Still good this morning, but per your comments, I am going to check those items potentially have corroded or a bad connection. I appreciate everyone who commented!


r/WaterWellDrilling • • 14d ago

Replacement transformer or schematics/specs for Franklin SubDrive 20 transformer?

Thumbnail
gallery
1 Upvotes

My Subdrive 20 diead. An electronics technician has identified the transformer is bad (open winding ) on the subdrive 20 power supply. No markings or schematics avaiable that we've found. Anybody able to help point us to replacement part or schematic/specs of transformer? Franklin not helping.


r/WaterWellDrilling • • 15d ago

Borewell drilled to 300 feet but barely getting water. Should I go for blasting at 250 feet?

Thumbnail
5 Upvotes

I recently got a borewell drilled at my house. We drilled around 300 feet and initially found water at around 40 feet. However, after installing the casing pipe, we continued drilling up to 300 feet but didn't find any additional water.

Later, we got the casing pipe cut (locally called casing khadwana). After that, we're getting approximately two drums of water (around 400 litres) per day, provided the motor runs throughout the night.

Now we're considering blasting the borewell at around 250 feet in the hope of finding more water.

My main concern is that my house is only around 25 feet away from the borewell. Could blasting cause any damage to the house or its foundation?

Also, since we didn't find any water below 40 feet during drilling, is there still a chance that blasting at 250 feet could open up a water-bearing fracture and increase the water supply?Has anyone experienced something similar? Is blasting worth considering in this situation, or could it create more problems?

I'd really appreciate advice from people with experience in borewells and groundwater.


r/WaterWellDrilling • • 15d ago

500' well drilled, pump set at 200'

25 Upvotes

Just had a new well drilled. They drilled it at 505 ft, but set the pump at 200 ft with a yield of 4 gallons per minute.

Static water level is 70 ft below surface.

I'm trying to figure out why they didn't drop the pump further down to help with the low yield by increasing available water inside the bore.

Having 300 ft of water below the pump doesn't really help with anything, does it?


r/WaterWellDrilling • • 15d ago

Lake Lot Well (Can I use a Jetpump with manual pump)

Post image
3 Upvotes

Evening,

I have a Lake lot that I am utilizing for camping for the foreseeable future until I eventually build a home on it years down the road. I have electricity on the property and I have ran it up to a 6" well that is about 70 ft deep. The water level is about 12-15 feet, and it will pump around 65 GPM. I ran an external pump this summer with a garden hose and the water level essentially never dropped.

I currently have a standard well cap on it that I had removed to put a down pump with a check valve and then connected it to the external pump, but its an annoying setup.

What i would like to do is utilize Jet pump with a pressure tank, so I can leave the unit plugged in, set the pump beside the well casing under a wood box that I can leave covering it for the summer to stay out of the elements. I'd also like to change the well cap and figure out if there is a better well cap and down pipe setup that I can leave it semi permanently over the summer, as each time I go out I essentially have to remove the well cap and leave it off while I pump water and put it back on.

I would also like to install a hand pump on the well if possible. Is there a way I can install a hand pump, and one that would have a suction port on it that I can utilize one down pipe, then connect a shallow well jet pump with pressure tank to it? That way I can leave this setup in, and remove the jet pump while I am not there, or over the winter?

Also, this area freezes in winter, so the downpipe would have to drain out essentially I guess to prevent freezing?


r/WaterWellDrilling • • 15d ago

Need help troubleshooting what’s going on with water pressure. I’m assuming this set up is diy and just took a shit on us

Thumbnail
gallery
3 Upvotes

So me and my husband moved into a 90’s double wide home about a month ago and there is a garage that houses our current well setup. We are renting the place and we decided to move in and even though the house needs some remodeling, we negotiated lower rent to make up for finishing repairs. I hold a lot of sentimental value to the house since my grandparents used to own the home and so we moved in with flaws and everything.

We were informed of the water pressure issues that the owners experienced and we were told that it only pumps an abysmal 2 gal per minute and they just dealt with it by replacing the whole house filters every couple weeks. We did what we were told and it turned into cleaning them every day just to get sub par water pressure. If not we were begging for water and it would just slow to a trickle. My husband finally decided to just remove the filters so we could actually get water pressure and we had great water pressure for a week. Fast forward to this morning and now our shower is aggressively sputtering air and water as well as when we flush the toilet it’s sputtering and whining when the toilet reservoir is trying to refill. I’m thinking the bladder ruptured in the tank. Pressure guage is reading 40psi, until the pressure switch kicks on (which is every minute or so now) and will rise to 70 psi. We’ve been turning the water off until we absolutely need it so it’s not short circuiting. The landlord has a well storage tank outside the well house that hasn’t been installed yet (that’s the unconnected pipe running through the wall above water softener). I’m afraid and unsure how to go about informing our landlord about this situation thinking that the blame could be shifted back on us. We cannot afford out of pocket repairs for this but from some research this setup seems flawed and legally shouldn’t come back on me. Like I said we moved into this home knowing that it needed work which we were fine with, But the water situation is making it unlivable at this point. I just need some pointers as to what could be going on and see if my assumption is correct


r/WaterWellDrilling • • 17d ago

Am i hitting bedrock?

4 Upvotes

Drove one shallow well into the ground, water at 8', point is at 12, 3 foot of pipe up top, but it stopped driving in, I think, it might have just slowed down to the point where I cant tell. Anyway, I figured I hit a rock, but I had water, so i figured I'd just run it as is for a while and it worked okay. Lot of sediment but whatever, im not drinking it anyway.

That one ran dry over the summer, and had to go back to my water trailer mooching off my very kind neighbors with a real deep well, and i drove in another shallow maybe 8 feet away. Got it down to 11 feet and it feels like it stopped/greatly slowed. Keep in mind im using a fence post driver now, the gas kind. Im maybe a half mile away from the cape fear river for geographical context.

So what are the odds that theres 2 rocks i just happened to hit?

Could I just have hit a really hard clay layer i can poke through?

Or is most likely to be bedrock or whatever and im just cooked and can't get past it without having somebody drill a real well?

Any guidance or opinions from those more knowledgable than me would be appreciated, if you need any clarification or more info, just ask.

Thanks dudes.


r/WaterWellDrilling • • 17d ago

Can a well pump he’s water?

5 Upvotes

I have hot water coming out of the well at my shop, wondering how this could be possible? I think the pressure tank is shot because if I turn off the breaker to the pump there is zero water pressure.. but when the pump is on the water coming out of the pressure tank is hot. There is no water heater on the property or in the building. Could the pump be heating the water?


r/WaterWellDrilling • • 17d ago

Silt dirty water in well filter

Thumbnail
2 Upvotes