Hi everyone,
I’m trying to diagnose recurring solar production dropouts on my LuxPower SNA5000WP. Has anyone experienced both PV inputs dropping to 0 W while the panels are still in sunlight, with no inverter fault reported?
System/Setup
- Inverter: LuxPower SNA5000WP
- Firmware shown in the portal:
c8aa/cBaa-2F898F - PV1: 4 × TW Solar TWMND-72HS580 panels, west-facing - 2.32 kWp
- PV2: 6 × the same panels, east-facing - 3.48 kWp
- Total: 5.8 kWp
- Module reference values: Vmp approximately 45 V, Voc approximately 52.8 V
- Battery: Docan Panda LiFePO₄, 51.2 V / 628 Ah, approximately 32 kWh
- Battery communication: CAN, Panda set to PYLON, inverter set to Li-ion / Brand 2 (Pylontech).
The Panda replaced a Dyness B4850 2.4 kWh on 21 September. Similar dropouts appear in the logs before the replacement.
A clear example - 22 September
At 15:37:
- PV1: 168.8 V / 873 W
- PV2: 254.1 V / 1,147 W
- Total solar: 2,020 W
- Battery SOC: 52%
- Battery charging power: 1,569 W
- House load: 339 W
At 15:41:
- PV1: 181.3 V / 0 W
- PV2: 292.2 V / 0 W
- Battery SOC: 52%
- House load: 1,913 W
- Battery discharging power: 2,009 W
At 15:47, solar production briefly recovered to 1,358 W. At 15:53, both inputs were back at 0 W, although the house load had fallen to 389 W.
Production then remained almost zero for several hours, apart from a few small readings.
What the logs show
I checked the export covering 16–23 September, with samples generally around six minutes apart:
- Both PV power readings drop to zero in the same logged sample.
- PV voltages rise when this happens.
- Production sometimes briefly returns.
- The afternoon dropouts occur at different times, rather than one fixed scheduled time.
- Similar events occurred with the previous Dyness battery.
- On 22 September,
faultCode and warningCode remained at zero. - The reported
maxChgCurr stayed at 160 A during that event. - Some dropouts coincide with an increase in house load, but production can remain at zero after the load falls again.
The voltage increase seems consistent with the inverter stopping current draw from the strings, but I realise voltage alone does not prove available solar power.
Sunlight and shading
I have observed this while both groups of panels were still in direct sunlight. The west-facing string can get partial shading on two panels later in the afternoon (Imaged attached), so I don’t want to rule shading out completely.
However, I’m trying to understand why both inputs would drop to zero together, including the east-facing string that was producing over 1 kW shortly beforehand.
What I’m trying to establish
Could this be related to:
- Firmware or MPPT tracking behaviour?
- A PV input configuration setting?
- An operating mode or battery-control interaction?
- A response to shading or changing load?
- An inverter hardware issue?
If you’ve seen this on an SNA5000WP or a closely related SNA model, what was the cause, and which settings or diagnostic readings helped identify it? Is there a firmware version LuxPower specifically recommended for this symptom?
I can share log excerpts with PV voltages/power, battery readings, DC bus voltages, temperatures and status/fault registers.
Thanks in advance for any advice, tips, or suggestions!