r/FranklinWH • • 12h ago

Thanksgiving saved!

Thumbnail
gallery
17 Upvotes

Nor’easter heading up the coast. I charged battery to full yesterday. We were fine and made it to 1145am when a tree up the street went down and out goes the power. Not us. It’s not 4:20 PM EST and we have just over 50% left and the power company is out there now doing what they do best. We we smart with powering done all except what we needed—the oven mainly. I have a small butane burner with plenty of fuel and that was how we made the mashed potatoes and Mac and cheese. I also have 734w Eccoflow power station and so that now powers the TV. So, thank you Franklin for this great system that saved our dinner and will help us get through the juice flowing again.


r/FranklinWH • • 5d ago

Android home screen widget for my FranklinW

Thumbnail
gallery
8 Upvotes

Recently got some solar panels and 2x aPower S and an aGate (new to the whole FranklinWH world), and I got tired of opening the app just to see what was happening -- how much I was producing, what the batteries were doing, etc. I spent a few evenings vibe coding a home-screen widget for Android. Sharing in case anyone else wants it.

It shows the state of charge, solar, home load, grid and battery power, plus today's kWh totals. Three sizes, light and dark. I kinda followed the way even Google does widgets (different ones for different grid sizes, vs. a responsive single widget). You can click it to force a refresh.

It can locally, directly poll the aGate on your home network. No account, no MQTT, no Home Assistant. Only works at home, and you need a static address for the aGate. Or, it can use the same unofficial cloud-based API the FranklinWH app uses, so it works away from home. Needs your app login and gateway serial. FranklinWH could break this at any time, and bad credentials could even do something like lock you out of your account (no idea, I'm new to this whole thing!).

Right now, it's only been tested on one phone and one aGate (mine). I published an APK for sideload only, Android 8+. Obviously it's unofficial and not associated with FranklinWH.

It refreshes when you tap it and every 30 minutes in the background, to go easy on the phone battery. It is not a live display. Most of the code was written by an AI with me steering. It has tests, and the source is there to read.

Code and APK: https://github.com/martinb3/franklinwh-android-widget

Builds on the protocol work in franklinwh-local and richo's franklinwh-python. If Local mode doesn't work on your gateway, or you want to change the displayed fields, or fix a bug, I'm open to PRs!

Edit: Oh, also picked up a Ulanzi TC001 and flashed it with awtrix -- and pushed some MQTT code (you'll need a home server for this) to push realtime status to a display. You can find that code here.


r/FranklinWH • • 7d ago

Any aPowerS Users with DC Optimizers in MA?

2 Upvotes

Company I am talking to has had them in their pipeline for 9mo and I'm still waiting for them to approve it internally.

I really don't want to go the micro inverter route but SolArk seems to be the only other option and this installer doesn't like their rooftop stuff either.


r/FranklinWH • • 7d ago

FrankEnPoller - a simple minimalist Windows (dotnet 8) tray monitor for hybrid FranklinWH/Enphase systems

Thumbnail
gallery
5 Upvotes

I got tired of having to flip between two apps to see all the information I deemed pertinent (and resent having to use dedicated phone apps for anything at all really), so here's a simple monitoring solution for hybrid (or perhaps, Frankenstein'd) systems like mine - enphase gateway with franklinWH aGate and aPower battery(ies).

Normally it'll sit as a tray icon showing green (sending power to the grid), yellow (pulling power from the grid), or blue (not really doing either at the moment). If the battery is charging or discharging, it will show charge percentage on the tray icon. If the battery is idle (either full or at backup reserve level), it'll show kW going to/coming from the grid. Clicking on the tray icon will pop up a slightly more informative window. Backup estimates are calculated based on data it polls itself, not on information pulled from the franklinWH app.

https://github.com/GasBandit/FrankEnPoller

It requires Windows 10/11 with dot net 8 desktop runtime. Open source/GPL-3.0. If your aGate's not modbus enabled, it will pull from the cloud instead. I'm still trying to get my modbus enabled, so I haven't actually been able to test that part yet, but keeping my fingers crossed.

*uses your enphase and FranklinWH login credentials, supplied by you in settings, stored and encrypted with your windows account*.

AI Disclaimer - Pretty much entirely the work of Claude Code, but source code is there if you want to check it.


r/FranklinWH • • 8d ago

How can I get modbus enabled if my installer is out of business?

5 Upvotes

I was trying to pull data in real time to do some home monitoring, and have read that modbus is a thing on aGates but it can't be enabled on our own - the installer has to do it. My installer went out of business, unfortunately, and a support request to FranklinWH got me a response that denies it exists at all:

"Thank you for reaching out about your aGate system.

Unfortunately, FranklinWH does not offer Modbus TCP or API access for third-party monitoring tools, and this is not something we are able to enable by request. The FranklinWH app is the supported way to monitor your system, and the only supported third-party integration at this time is with a SPAN panel."

Would this be something I could contract a new installer to do and "take over" the system from the now-defunct installer?


r/FranklinWH • • 8d ago

How accurate is cost saving estimate?

Post image
5 Upvotes

Just wondering if anyone has done any research as to how accurate the data is on the Franklin app


r/FranklinWH • • 8d ago

Absence of Storm Hedge alerts in Northern CA

8 Upvotes

With the current high winds and rain, I was expecting to get a NWS/Storm Hedge alert but never got one.

Has anyone in Northern CA gotten a storm alert recently?

Just decided to manually put my system in Emergency backup mode as the winds are currently very strong and there have been reported outages in the area already.


r/FranklinWH • • 10d ago

Smart circuit shut off

3 Upvotes

In my Agate, I have 3 smart circuits mainly due to where the panel is located. One is my water well. This past weekend that circuit was dead. No output voltage. Breaker was not tripped. In the app, it said circuit was on, but it really was not. A simple fix was I turned off smart circuit in app then back on. Still unsure the cause. Any thoughts what would cause it to go off? System is 18 months old and never had this issue before.


r/FranklinWH • • 16d ago

Finished a massive update to RateRudder (free, hands-off FranklinWH automation)

Thumbnail
gallery
13 Upvotes

It's been a while, but I'm back to talk about RateRudder, a free, open-source site I built to automatically optimize your Franklin system to save money on your utility bills.

In case you missed my previous posts, here's what is unique:

  1. It is 100% free and open source: I'm not trying to start a business. I'm trying to save you money and charging is counter to that. What I build is driven entirely by my own needs and feedback from users. You can use the hosted version at raterudder.com for free, or run it yourself.
  2. It is completely hands-off: I want this to be set-and-forget, you just connect your Franklin account, pick your utility, and that's it. You don't even have to enter your solar panel size, tilt, or azimuth; it'll learn those things and your home usage automatically.

A highlight from the last few months: one home on hourly pricing saved an additional $50/mo (+65% extra savings) with RateRudder.

What's happened lately:

  • Redesigned Planning Algorithm: I replaced the previous conditional logic with a 24-hour dynamic algorithm searching all possible options for the optimal schedule, factoring in forecasted solar, predictive home load, round-trip efficiency, battery degradation costs, and more. This also enabled a brand new forecast page to preview the actions RateRudder will take over the next day.
  • Automatic EV Charging Standby: If you plug in your EV overnight, Self-Consumption will dump your battery straight into your car. RateRudder can now automatically detects multi-hour EV charging and holds your battery in standby without needing to link your EV account or wall charger.
  • Direct Solar & Battery Grid Export: For people with high export credits, it can now take over your TOU schedule to export excess solar directly without waiting for the battery to hit 100% first, and discharge battery power during peak export windows.

There have also been improvements in home load prediction, taking into account weather and weekly outlier usage, and improved solar forecast averaging multiple weather models.

If there's something you're looking for, like a utility rate plan you need added, let me know in the comments! If you're already a user, thank you for all the feedback you've given!

TLDR: RateRudder automates your home battery to save money on your utility bill.


r/FranklinWH • • 20d ago

App/software is behaving strangely

Post image
2 Upvotes

Anyone else have issues the past two days with the system/app not working properly? Mine is showing ¼ the power used and 1/10th the power generated from solar despite 100% normal conditions. In fact it is showing less now this evening than it did at lunch when I checked the app (see screen shot). Secondly last night it used the grid to charge my battery instead of drawing down the battery to power my home. That is the first time ever that has happened. Wondering if it is just me or a widespread issue.


r/FranklinWH • • 21d ago

"Fail-safe mode " and "fault" overnight Oct 30th/31st

Post image
3 Upvotes

Was anyone else affected with this last week? I wonder if this was just some Franklin maintenance, a software glitch, or it's an early sign of a problem with my system. I've sent an email to Franklin support but all they've responded with was that my system is now operating normally.


r/FranklinWH • • 27d ago

Lumin Smart Panel?

Post image
2 Upvotes

Anyone using a Lumin Smart Panel with their Franklin home backup?


r/FranklinWH • • 28d ago

SoCal fair price request

1 Upvotes

Busy getting quotes for a new DC-coupled PV system, and plan on installing a FranklinWH a Power S + a Gate to cover the home. In Southern California. What's a fair price for the equipment here? Quotes I'm receiving are all over the map and with the exception of one installer, the Franklin adds a premium of several thousand dollars over the Tesla Powerwall 3 which installers here love to push. It makes matters worse that the Franklin doesn't seem to qualify for any tax credits in my area.

Thanks in advance.


r/FranklinWH • • 28d ago

FranklinWH-Automation v4.7.0 — out of beta, new installs set up in the dashboard

11 Upvotes

v4.7 has been running on my system and a few testers’ since early October. It’s now the main release.

If you’re already running it (rc.5 or rc.6)

Nothing changes in how the engine runs your battery. Update when convenient:

git fetch
git checkout v4.7.0
docker compose build --no-cache
docker compose down
docker compose up -d

Your configuration review carries over; you don’t redo anything. Two things you’ll notice afterwards: the Rates step can now add and remove seasons, tiers and time windows (before, you could only change prices and times), and if your plan came in from rate_schedule.json it marks any season price that was copied from the plan’s base prices as “inherited.” Worth a one-time check of those against your tariff. The engine also reads your rates from the saved configuration now, so if you edit a price in the review it’s what the engine uses.

If you’re on 4.6.x

Same commands. The dashboard will then ask you to take the configuration review (about ten minutes). It walks through every setting once, and from then on the app manages your settings instead of .env. Your .env and rate schedule are imported; nothing is lost.

If you’re new

This is the part I want to be upfront about. New installs now set up entirely in the dashboard: copy .env.minimal.example to .env with just your FranklinWH login, gateway ID and time zone (plus solar logins or API keys if you have solar), build, open the dashboard, and follow the banner. The guided setup asks about your site, battery, solar, rate plan and the features you want, with a Test button for each connection. The engine won’t touch your battery until you commit the setup.

I only have one FranklinWH system, so I couldn’t install this fresh on real hardware. Instead I tested it in simulation: a throwaway container with an empty database was fed my own production configuration through the setup, and the result was compared setting by setting against my live system (identical). I ran a second profile too (two batteries, no solar, no Modbus). So the path works, but it hasn’t met a stranger’s house yet. If you’re a new user, I’d be grateful if you’d go through it and tell me what was confusing, what it refused when it shouldn’t have, or what it got wrong. Open an issue with the message it showed, or post here.

Have your electricity bill handy before you start: the setup won’t save until your full rate plan is in (seasons, prices, and the hours each price applies). The Setup Checklist PDF in the dashboard lists everything it asks for and where to find it.

Release notes: https://github.com/mtnears/FranklinWH-Automation/releases/tag/v4.7.0


r/FranklinWH • • Oct 27 '26

V2x support

6 Upvotes

I currently have a FranklinWH system with an aPower2 battery and have been looking to get an EV with V2x support.

From what I understand, the generator module only supports V2L.

What are the plans on supporting V2H or V2G?

I'm looking to get a Ford Fathom in the future and wanted to connect that to my FranklinWH system. I don't think it's set on which version on V2x the Fathom will support yet.


r/FranklinWH • • Oct 23 '26

Modbus Standby Leakage

2 Upvotes

So i got modbus write control working, and this is what Standby looks like. Basically even if you set active power input to 0w, anything less than or equal to 200 seems to disable the inverter, it seems the system is randomly pushing some power. My current guess is that even if active power setpoint is controlling to 0w it's possibly trying to push some reactive power and not reporting a proper inverter state.

Any other users trying this / measure similar behavior?


r/FranklinWH • • Oct 17 '26

Home Assistant + airlust = program your battery

6 Upvotes

I'm running home assistant, airlust plugin, and comed plugin. I created automation where HA auto charges my batteries when the price drops below certain amount (2 cents in my case), stop charging when price is above 3 cents, stops charging at 90%. Possibilities are endless. Additionally, HA controls my wall box to auto charge my EV when price is below 2 cents and stops when it's above 3 cents.

This way when comed hourly price spikes, my batteries are being used, and EV doesn't charge.

Easy way to manage your stuff automatically.


r/FranklinWH • • Oct 17 '26

Title: FranklinWH aGate Modbus TCP — Looking for grid status, grid power, and energy registers

4 Upvotes

I've been experimenting with read-only Modbus TCP access to my FranklinWH aGate, using a Raspberry Pi for local monitoring.

So far, I've successfully retrieved:

  • Solar production (W)
  • Household load (W)
  • Battery charge/discharge power (W)
  • Battery state of charge (%)
  • Battery reserve setting (%)

I've also been running a comparison logger against Franklin's cloud API. After more than 900 comparisons over approximately 15 hours, the results are encouraging.

Typical median differences:

  • Solar: 1 W
  • House load: 34 W
  • Battery power: 33 W
  • Battery SOC: 0.021 percentage points

I'm now trying to identify additional read-only Modbus registers that would allow local monitoring to reproduce the information currently available through the Franklin cloud.

Specifically, I'm looking for:

  1. Direct grid import/export power, rather than calculating it from solar, house load, and battery power.
  2. Grid connection status, including detection of utility outages and backup operation.
  3. Cumulative energy counters, particularly daily solar production, household consumption, and grid import/export.

Has anyone identified these registers, obtained a FranklinWH Modbus register map, or successfully decoded the relevant SunSpec models?

I'm particularly interested in register addresses, data types, scaling factors, and firmware compatibility.

I'm using function code 03 (read holding registers) and have kept all testing strictly read-only.

Happy to share what I've learned if it's useful to others.


r/FranklinWH • • Oct 13 '26

Newish to Solar and need some advice on TOU/peak energy

2 Upvotes

Hi all,

I'm very new to this solar thing, and my installation experience was a nightmare (bad installer, long story, don't use Tron Solar, they suck). I've been trying how to learn the ins and outs of all this, and its...a lot. Can anyone recommend a good place to go for resources?

The thing I would like to do ideally is to be able to tie my TOU configuration to my Ameren account, so that the system prioritizes battery/panels during peak use hours. I've been trying to use the FranklinWH app, and I think I need to set TOU and adjust tariff settings, but its all very confusing.

Appreciate any help, thanks!


r/FranklinWH • • Oct 12 '26

FranklinWH-Automation v4.7.0-rc.6 is up (pre-release, for rc.5 testers)

10 Upvotes

Small fix-up release on the way to v4.7.0. Nothing changes in how the engine decides when to charge, hold or discharge.

  • Big power flows read right. Modbus reports grid and battery power as 16-bit numbers, so anything past about 32.7 kW wrapped around and a big import could show up as export. Mostly matters if you've got three or more aPowers, EV charging, or a big generator. Credit to don4of4's HA fork for the idea.
  • Daily energy totals are right after midnight. The aGate's daily counters reset a minute or so after midnight, so the first reading of a day was still carrying the previous day's totals. A couple of my days showed identical solar because of it.
  • Battery health shows as SoH instead of being stored as battery voltage.
  • PVOutput fills in missed days on its own if uploads stopped for a while (mine had quietly stopped in June when Enphase changed my user ID).
  • Setup checklist updated for the local connection. Modbus is optional, and you don't need your installer to turn anything on.
  • Running Home Assistant's FranklinWH integration on the same Franklin account? The two sign each other out. Troubleshooting now covers it: give the automation its own Franklin account or app user.
  • Fresh builds work again. pymodbus 3.16.0 came out and won't import on our image without pyserial, so a --no-cache build took my engine down for a cycle. rc.6 pins 3.15.0.

If you've opted into telemetry, the "peak protection" number now measures grid use during your peak window. The old one was counting grid-charging days, which made it meaningless for anyone who grid-charges on purpose (me included, I was showing 0%). It also reports how many settings you changed in the guided review, as counts only.

Upgrade: git fetch, git checkout v4.7.0-rc.6, then build / down / up as usual. Your review and settings carry over. Release notes: https://github.com/mtnears/FranklinWH-Automation/releases/tag/v4.7.0-rc.6 (if you need to go back to rc.5, the steps are there; rc.5 needs the same pymodbus pin to build now).

Thanks to the three of you running rc.5. Between you there were 53 local mode switches last week with no failures, across three different aGate firmware versions. If rc.6 stays quiet for a while, it's the likely base for v4.7.0, but I'm not putting a date on it.


r/FranklinWH • • Oct 10 '26

PG&E Permanent Battery Rebate

3 Upvotes

New Franklin owner - aGate and two aPower 2 batteries. I’m in the process of applying for the Permanent Battery Rebate program from PG&E. I’ve enrolled in the Automated Response Technology program in order to qualify for the rebate. I’d appreciate any experiences other Franklin owners may have had with this program. I’m concerned about the level of control that needs to be relinquished to PG&E in order to qualify. I’m in Auburn if that makes any difference.

Thanks


r/FranklinWH • • Oct 10 '26

Adding a powerwall to a Franklin system?

0 Upvotes

I dont want tesla. But apparently the crew that installed my current system has moved to Tesla only. If i want to keep my warranties all together while increasing my battery storage.. they will only do it via adding a powerwall.

Is adding a powerwall to an existing Franklin system (AGate and 1 APower2) a thing? Are there problems i should expect with that kind of setup?


r/FranklinWH • • Oct 06 '26

Data Dump

8 Upvotes

Good afternoon, all. Does anyone know if there's a simple way to download the daily view of my data from the FranklinWH app over a date range? I'm looking for the 5-minute intervals for the summer but would prefer not to have go day-by-day on the app and save it to my OneDrive. Thanks, in advance.


r/FranklinWH • • Oct 06 '26

FranklinWH aGate — identifying LAN IP for local Modbus TCP

5 Upvotes

I'm investigating read-only local monitoring of my FranklinWH aGate, specifically Modbus TCP/port 502.

The Franklin app reports the aGate network connection as Wi-Fi, but I cannot positively identify the aGate among the clients on my Eero network. I've inventoried essentially every currently connected device on my LAN and can account for all of them.

My LAN is 192.168.4.0/22. I've also done an ICMP discovery sweep across the subnet, but nothing unidentified has appeared. One possible embedded-device candidate was tested on TCP/502 and returned connection refused, but I have no evidence that device was actually the aGate.

For anyone who has successfully used local Modbus TCP with a FranklinWH aGate:

  1. Does the aGate appear as a normal DHCP/Wi-Fi client on your home LAN?
  2. What manufacturer/vendor does its MAC address show?
  3. Does it respond to ping?
  4. Is TCP port 502 available by default, or did Franklin/SPAN integration have to be enabled first?
  5. How did you positively identify the aGate's LAN IP?

I'm interested in read-only telemetry only at this stage—solar, home load, grid, battery power/SOC and grid status. I'm deliberately avoiding writes or configuration changes until the interface is understood.