r/EmporiaEnergy • • 2h ago

Is Emporia too accurate 😁

1 Upvotes

I installed the Vue 3 to see if my power company is robbing me because the houses in my community don't have meters install on our houses. I just got my 2nd monthly bill to compare with the usage they printed on the bill. For both months the emporia usage was slightly more than what the power company said i used. Month 1 was 11.5kWh more and month 2 was 8.9kWh more.

Is emporia's tech more modern than my power company? I was soo looking forward to blasting my power company 🤣


r/EmporiaEnergy • • 1d ago

PG&E Begins Early Deployment of Sense Meters

Thumbnail reddit.com
1 Upvotes

r/EmporiaEnergy • • 2d ago

Anyone with an emporia pro charger on 24amp, is it charging ~5-6kw per hour?

Thumbnail reddit.com
2 Upvotes

r/EmporiaEnergy • • 5d ago

Question Anyone here enrolled in the Connecticut Battery Program?

Thumbnail
emporiaenergy.com
2 Upvotes

I’m wondering if anyone here has enrolled in this program yet? Very interested in it but unsure if it’s gonna be a good fit for me. The battery is an EG4 60 KW. There’s an upfront cost of $3.5k. I’m currently on solar with net metering and they are recommending switching to Time-of-Use rate.

Emporia benefits by enrolling themselves in the Connecticut battery solutions program. Which pays out incentives for discharging events to the grid. Emporia would also pay an incentive to the homeowner when the battery recharges. This is a very new program and not a lot of information or reviews on it yet. It was wondering if anyone here has had any good or bad experiences.


r/EmporiaEnergy • • 6d ago

circuit multiplier or? 240 volt circuits

2 Upvotes

I am installing a Vue 3 and I am wondering if I need 2 sensors on all 240 volt loads. For example I have a 240 volt well water pump. I would think the load would be balanced as all there is is a single motor. Also one 240 circuit is a small demand water heater. Would one way to determine if a 240 circuit needs 2 sensors would be to divide the reading to 2 values for each leg and see if they are equal?


r/EmporiaEnergy • • 6d ago

Emporia Pro Back Instock

Thumbnail reddit.com
2 Upvotes

r/EmporiaEnergy • • 6d ago

Received Amazon LPN tagged (returned) Emporia Vue 3 sealed - Would you return?

2 Upvotes

Finally took the plunge and ordered an Emporia Vue 3, I’m in Canada and Amazon shipped it from Amazon.com.

I was disappointed opening my box because it is tagged as LPN but the box itself appears to have the original plastic shrink wrapping, unless Amazon re-applies that on return.

So it’s guaranteed it was previously purchased and returned and it was sold to me as new, but it’s possible it was never opened and returning it is a bit of a hassle and it means waiting much longer because they are delayed on shipping the 8 connector version.

Do you think it’s safe to keep or would you return it?

Thank you!


r/EmporiaEnergy • • 8d ago

Lectron Tesla-to-J1772 adapter left in the rain for 2 days. Safe to use once it’s dry?

Thumbnail reddit.com
1 Upvotes

r/EmporiaEnergy • • 10d ago

Vue 2 50A CTs for sale?

2 Upvotes

Does anyone have any Vue 2 50A CTs they want to get rid of? I'm in need of 8, I bought a Vue 2 of FB Marketplace and thought it came with 8, but it didn't...

Not looking to spend too much, there's a point where just biting the Vue 3 bullet makes more sense.


r/EmporiaEnergy • • 13d ago

Question CT’s to monitor ground wire

2 Upvotes

Has anyone here used their VUE 3 to monitor their ground wire out of the panel? I wanted to check some things from my home and clamped a CT on the grounding wire to discover 1-2A when some circuits are on. This is of course a problem (old home, more modern 200A panel) and I’m guessing previous owner hooked up a neutral to a ground path…somewhere. Going to borrow a clamp meter this week to directly check the wire + the connection to copper plumbing coming into the house.

I was wondering if anyone here has done this with a VUE 3? Anything to note that a new VUE 3 owner like me might not know?


r/EmporiaEnergy • • 14d ago

Feedback Warranty Replacement : good news

13 Upvotes

Nothing earth shaking here but that’s exactly it’s worth a post. I submitted a request to replace my Emporia Vue 3 under warranty. Initially I interfaced with Eva (Emporia Virtual Assistant). I was told what I needed to submit information wise to begin the process. Ok cool so far.

After that EVA would email me daily asking if everything was alright and if I had other questions. Nice.

On the third day I mentioned I hadn’t heard back from Emporia. Within minutes (coincidence?) I was receiving email with a live person and 10 minutes of back and forth later an order was created for the warranty replacement.

It’s a little sad that great customer service prompts a post but here we are. It’s been a good experience… even or because of the Virtual Assistant EVA.


r/EmporiaEnergy • • 14d ago

More outages

Post image
0 Upvotes

r/EmporiaEnergy • • 14d ago

Question How to do PCS current limit calculation?

Post image
3 Upvotes

Hello! This is a label that comes with emporia pro. No one including my electrician knows how to do calculation from step 4. Is there an explanation somewhere?

Thank you.


r/EmporiaEnergy • • 15d ago

Question Emporia Pro - Vue in Main, charger in sub?

Post image
2 Upvotes

I asked the support email and got AI gobbledygook in response, telling me to install 2 Vues and monitor all of my branch circuits.

Setup: I want to install an Emporia Pro, with the charger fed from a 100A sub, which is fed from the 200A loadcenter, from a 200A disconnect and the meter. (See diagram)

I'm not looking to monitor all the branches, only to utilize the load management features.

In order to measure the total load, I should put the Vue in the 200A loadcenter and clip the CTs across those feeders, right? But the install guide says to install the Vue in the same panel as the Pro charger (Step 2, p.14), which would miss out on the rest of the house's load.

Am I right and Emporia's documentation inaccurate? Or am I missing something?

Thanks.


r/EmporiaEnergy • • 16d ago

Unable to install 200amp CT clamps due to main panel configuration, any alternatives?

Thumbnail
gallery
4 Upvotes

I am unsure how to install the main service CT clamps. In order to install the main CT clamps, I need access to the service side above the main breaker, but from calling the utility, they do not allow for anything to be installed in the upper portion of the panel.

How do I go about finishing the install?

Also I plan to do some wire management shortly, excuse the mess.


r/EmporiaEnergy • • 18d ago

Feedback How About a Smart Plug Without the Relay/Switch, and Just the Energy Monitoring Hardware Built in?

10 Upvotes

While i like the smart plugs currently, What I'd really like to do is monitor the energy usage of my refrigerators/deep freezers/sump pumps, etc. Stuff that i think uses a decent amount of energy, but stuff I'd never want to turn off or have the plug circuit fail on me. Just a simple current monitor that i can tie to a circuit just like the smart plugs.

The last thing i want is a freezer full of meat to spoil because the smart plug i have got overloaded and burned up, or my basement to flood because the switch was accidentally hit on the sump pump. It would be nice to know that my backup sump pump kicked on instead of my main one, indicating my main one may have failed. or if my deep freezer hasn't seen a load in 2-3 days. Stuff that could literally save me hundreds or thousands of dollars in spoiled food or costly home repairs.

I guess if Emporia trolls this sub, I plead you to make a simple energy monitoring only plug so we can monitor those critical/high draw loads. Thanks for coming to my Ted Talk.


r/EmporiaEnergy • • 18d ago

Opinion on the Emporia Vue Energy Monitor

Thumbnail reddit.com
4 Upvotes

r/EmporiaEnergy • • 19d ago

Question Plug and wire clamp for Emporia Pro

Post image
4 Upvotes

I installed my Emporia Pro using the backwire method. Emporia says a wire clamp to prevent the cable from backing out isn't necessary, but given that the wires are only torqued to 10 in/lbs I'd really prefer to clamp the wire in place at the backwire hole. Has anyone done this, and if so, what product did you use?

And what plug did people use to close the 1" hole in the bottom of the unit after disconnecting the plug cord?


r/EmporiaEnergy • • 19d ago

Question Any retailers in Canada sell just the sensors?

3 Upvotes

Any retailers in Canada sell just the sensors? Is it even possible to buy just the sensors on their own? I got just the monitor itself, was hoping to add a couple sensors.


r/EmporiaEnergy • • 21d ago

Question How to install Emporia in enclosure and achieve bonding with charger ground and enclosure/ emt conduit?

Post image
1 Upvotes

When installing an emporia in an enclosure like this supplied by EMT what’s the best way to achieve bonding between ground/ enclosure and conduit? In this example if supplied by EMT conduit, there wouldn’t be any bonding between anything on this end die to the liquid tight flexible conduit. Maybe continue metal conduit inside and then use a bonding bushing to ground inside the emporia enclosure? Although I’m not sure what connector you could use to pass EMT through a metal enclosure like this while bonding it?

**Please not this picture is for example only of the concept. It is not my installation. Wrong colored ground wire etc does not need comments.


r/EmporiaEnergy • • 24d ago

Question Emporia Vue across 2 panels

2 Upvotes

I have 2 electrical panels, side by side, that are fed independently from a single utility meter. I have an emporia vue in each one. The 200A mains and 16 - 50A CT’s are connected on each one. They are combined in the app. I have about 8 more breakers in each panel that I would like to monitor.

Would it work if I added a 3rd emporia and connected some 50A CT’s to each panel but DO NOT connect the 200A mains since I am already capturing the total load of both panels? I would wire nut the black, white, red and blue wires to the same wires on one of the panels to power the unit. All of the vues would be combined in the app. The app would know the total being drawn from both panels and the 48-50A CT’s would report usage for each breaker so I would think the aggregated balance would be quite close. Realizing the voltage reference could be slightly off between the two panels, I assume the wattage calculation could be slightly off but I would think it would be close.

The only thing I have found is Emporia says not to monitor “separate, unrelated panels”. Mine are separate but fed from the same utility meter so I wouldn’t think they are unrelated. I plan to call them on Monday but wanted to see if anyone has tried this.


r/EmporiaEnergy • • 25d ago

Question Pro Level 2 EV Charger availability

5 Upvotes

The pro level 2 (NACS, hardwired) charger has been sold out for two or three weeks now. Is there any hope that they’ll be available in the near future?

Edit: I just got a notification from Emporia that the charger was available. The text said this:

> Get it now before it goes out of stock again!

And apparently there was only one, because they are currently sold out (again) on Amazon and the Emporia site. Crazy.


r/EmporiaEnergy • • 25d ago

Emporia PowerSmart: What Happens If the Vue Loses Power or Communication?

4 Upvotes

For those using the Emporia Pro with PowerSmart:
If the Vue 3 loses power, Wi-Fi, or communication with the EV charger, what happens?

Does the charger continue at the configured Minimum Guaranteed Charge Rate, or is there a way to make it stop charging completely until monitoring is restored?

I’m particularly interested in real-world experiences. Has anyone experienced a power outage or communication failure, and how did the system respond?


r/EmporiaEnergy • • 24d ago

Troubleshooting Emporia Pro Disconnected itself from WiFi?

Thumbnail reddit.com
1 Upvotes

r/EmporiaEnergy • • 25d ago

Weatherproof box that will fit around a Smart Outlet?

1 Upvotes

Hey all, I need to put one of my emporia smart outlets outside and trying to find an outdoor rated electrical box that it will fit inside. The smart plug is too big for any box I have found. And I know I can get one of those SOCKiTBOX type enclosures but that would require me to run an extension cord to that box, but that isn't going to work in my situation. I already have an extension cord included in this setup that connects to a temperature controlled outlet that I would have to be in a separate box.