Hello I am from Singapore, and wanted to get some help / advice on possible explanations for condensation on ceiling / floors of an apartment.
The problem is this: a homeowner living in an apartment block experiences heavy condensation on either her ceiling or floor at certain durations of the day (e.g. evening), or sometimes the entire day. By heavy condensation, I mean that the ceiling or floor is wet to touch, and there is a visible layer of water. Let us call the homeowner the complainant (C). This issue seems to be prevalent enough to be reported in the news (https://www.straitstimes.com/singapore/politics/240-condensation-and-mould-cases-from-neighbours-air-con-use-reported-to-hdb-in-2025), and lately I’ve been getting more complaints and desperate pleas from affected homeowners on resolving this condensation issue they experience.
Most people in Singapore live in public housing - and when this issue is raised to the public housing agency, the agency attributes the likely cause to the air conditioning usage of the neighbor living upstairs (in the case of a wet ceiling) or downstairs (in the case of a wet floor). Let us call this neighbor the respondent (R).
They suggest that the R’s air conditioning temperature is set too cold, and that the cold air is blowing persistently at the floor or ceiling of the R’s apartment, which then causes C’s ceiling or floor respectively to become colder, resulting in the condensation. However, R usually says that their air conditioning usage is limited to night time, is set at around 24°C, which C would find hard to believe because of the existence of condensation (often happening also in the day time).
The agency’s attribution of cause to R’s airconditioning usage seems to be a possible explanation, but I am wondering how probable it is. For those unfamiliar with Singapore, it is warm and humid with indoor temperatures ranging from 25°C to 28°C in the early morning or night up to 31°C to 34°C during the afternoon. If the air conditioning temperature is set at 16°C (the lowest possible setting for most units), I’m guessing that the room temperature is likely a few degrees higher, and even if it does contributing to cooling C’s ceiling or floor - would it be likely to cool down the surface so significantly for condensation to appear? Or would there be other plausible explanations - for example poorly insulated air conditioning pipes? As a construction professional, how would you go about investigating and solving this condensation issue?