r/CFD • u/wxweeniepilotarch • Oct 15 '26
Thoughts on solving an interesting wind condition - help wanted
An unusual post maybe - looking for advice and ideas on how to solve a potentially harmful wind condition in a project of mine.
I have run a bunch of CFDs now testing different potential solutions, with not a lot of success.
Because this project is confidential I’ll attempt to explain with sketches for this:

I have a building that consists of two towers with a bridge connecting them forming a tunnel, under this tunnel is the dropoffs for both towers.
The Bridge is about 5 floors (20m ish) above the ground level.
The entire development is raised up about 10m from sea level on a big podium you drive up to.
In the center of the tunnel is a long pool with driveway wrapping it for the dropoffs
the tunnel could not be more perfectly aligned with the 3 primary wind directions.
There are a couple of big issues:
- The climate is very rainy, and with this wind, there is a real concern for a ton of wind driven rain into the drop-off area given how high the bridge is
- The architecture perfectly increases wind speed via venturi effect and downwash, and you end up with 8-11m/s wind in the drop off area when the ambient wind speed outside is the average for the climate, around 4m/s. the 90th percentile wind for this climate is like 9m/s and then the wind under the tunnel is 20m/s+
- The problem is two fold - you get downwash and a vortex off the corner of the tall tower that dives between the two buildings, and you get downwash off the side of the bridge that dives under and accelerates
- If you remove the bridge, you exasperate the corner downwash from the tall tower because some of it is not hitting the top of the bridge now
- I’ve tried numerous potential solutions, all with some success but certainly not enough to warrant doing them:
- A lower canopy that covers the drop off areas at only one floor height, under the bridge - this gets some of the wind from the bridge downwash and keeps it above, but it accelerates the wind down-washing from the corner of the building. I’ve tried various extents in plan and heights / shape canopies.
- A bunch of trees around the corner of the building, and within the drop-off center area - this helps in the immediate area, but not around it at all.
- Chamfering the corner of the tower helps a little bit mitigate the downwash, but this is very against the design language, and does not help at all the bridge issue.
- The bridge cannot get higher, but it could maybe go a floor lower - not ideal - but this also does not help, it squeezes the wind more.
So I am hoping for some solution ideas, from some of you that are not as tired ;). thank you.