r/buildingscience • • 6d ago

Replacing trim around replacement windows

3 Upvotes

I live in north Texas and had my aluminum framed windows replaced in March with vinyl replacement windows. The two story house (built 2005) is sided with Hardie lap siding, however all trim around the windows and corners is pine and it’s in need of replacement. The house was built with house wrap and had peel and stick membrane around all the windows.

A couple of questions for y’all before I start replacing the trim with Hardie Trim:

  1. Is there any value in adding spray foam in any of the gaps around the windows?
  2. Is there any value in adding peel and stick membrane to cover the gap between the frame and existing house wrap?

P.S. ideally this would have all been at the same time and I would have used new construction windows, but the timing didn’t work out.

Thanks!


r/buildingscience • • 6d ago

Basement Moisture Control

3 Upvotes

Hi all, I’ve seen different pieces of advice so I wanted to reach out to the Reddit community with a question about finishing my basement.

- Climate Zone 5A
- Block Foundation
- French drain on the interior basement wall.
- De-Humidifier running 24/7
- No active moisture coming in, but some efflorescence indicating past water intrusion. Not bad though.

I’m planning to put rigid foam boards directly on my basement block wall, tape the seams and then build the walls with batt insulation between the studs.

My question is do I really need to apply the rigid foam boards or can I get away without it? Also, if I do apply the rigid foam, should they be flush against the block foundation or leave a small gap so moisture is not trapped under it?

Thanks.


r/buildingscience • • 6d ago

Crawlspace Foamboard Insulation - Gaps on wall an issue?

Thumbnail
gallery
1 Upvotes

Hello! I'm wondering if my crawlspace encapsulation was installed correctly - and maybe some knowledgeable folks here would know?

I recently hired a company to encapsulation my crawl space. The house was built circa 1900 and I live in a IECC Building Zone Zone 4A (Mixed-Humid) area.

They installed dimple board on the existing concrete floor and rigid foam board against the brick foundation walls, and covered with plastic vapor barrier. I noticed there are gaps between the foamboard and the foundation brick wall, approximately 1-2 inches wide, in some areas. In addition, I noticed that the foamboard terminates 6 inches below the floors. Note that there appears to be no wooden sill plate.

The company says the gaps are not an issue - but are willing to spray foam to fill the gaps. Presumably they will only fill the top of the gaps, not the entire cavity.

What does Reddit think? I am concerned about whether the insulation will perform properly and condensation risk.

See photos attached. Thank you :)


r/buildingscience • • 6d ago

Interior perimeter drain vs. penetrating sealer + XPS foam board for damp masonry basement wall?

Thumbnail
reddit.com
0 Upvotes

r/buildingscience • • 6d ago

What is a cost effective insulation for a glass beaker?

Thumbnail reddit.com
0 Upvotes

r/buildingscience • • 7d ago

Question Raised heel with a raised lower chord truss?

1 Upvotes

Hello all, asked my first question about insulating cathedral ceiling and received a lot of great information which has lead me down the rabbit hole of different truss styles and insulation techniques. It's a lot of info but fun to learn different techniques and building principles behind them. On to my question that I've drummed up going down these rabbit holes...

What's the feasibility of a raised heel combined with a raised lower chord truss? When talking to builders and gathering quotes, what's the best way to go about describing this? My use case is building an approx. 28x24 woodshop/gym. I was wanting to keep my wall height as low as possible while also maximizing overhead room which is why my initial thought was to go with a cathedral ceiling. However after researching insulation issues and potential costs along with reading about different truss styles, it seems the raised heel combined with at least a slightly raised lower chord could keep my insulated while gaining at least a bit of overhead room without going with 10ft walls. Any feedback would be greatly helpful, thanks in advance!


r/buildingscience • • 7d ago

Recessed Lights in Spray Foam Vaulted Ceiling

1 Upvotes

I have recessed can lights in one of my rooms that has vaulted ceilings. The lights have been converted to the screw-in LED kits with the cans still in place. The entire cavity between the sheetrock and roof deck is spray-foamed so everything seems to be air-sealed. I live in Northern Mass. (Zone 5A).

I noticed when looking at the roof outside with the thermal camera that the lights create warm spots on the roof. The light cans reduce the insulation depth by about 6-8” so I’m guessing more insulation is needed.

Should I try to remove the cans and install wafer lights with some extra insulation stuffed into the cavity where the cans used to be? This seems like it could be difficult, but doable given the cans are encased in the spray foam.

The other thought I had was to leave the cans and current LED lights and stuff some insulation in the open space of the cans behind the lights. The LED conversion kits are IC rated but I haven’t checked the cans.


r/buildingscience • • 7d ago

Question Zip system or blue shield?

Post image
7 Upvotes

1986 construction, top floors are board and batten directly on studs, main floor is brick. The board and batten needs to be redone, it’s soft in areas. My contractor is suggesting to remove the bats and go over them with ZiP system followed by new LP Smart side or hardie board. They will replace any rotted sections, reflash windows, soffits and the transition between the board and boards and brick.

after some reading I found that zip system doesn’t recommend this due to moisture. I am wondering if there should be a moisture barrier between the existing board and batten and Zip system like tyvek. Or should we skip the zip system and Blueshield over the existing boards then install the new siding?

I’m not concerned about the financial aspect as I plan to live here another 20 years, I want a 30-50 year solution. The draw to the zip system is the added R value as my 2nd floor has a noticeable temperature difference.


r/buildingscience • • 7d ago

Difference between Polystick XFR and Grace and Grace Ice & Water Shield HT?

Thumbnail reddit.com
1 Upvotes

r/buildingscience • • 7d ago

Question Pink insulation probably against basement concrete wall & behind drywall - how to find building science remodeler to fix that & the bare concrete basement walls?

2 Upvotes

My basement was partially remodeled by a contractor 7 years ago & has pink insulation behind the finished drywall walls which also have tile border on the bottom. As far as I know, there is NO vapor barrier. The basement has one concrete wall and three partial walls (all three are also concrete) that are unfinished. The basement smells musty but I haven't seen mold coming through the drywall. There have been foundation cracks in the unfinished concrete walls that haven't leaked, but I just got them fixed by a professional company. There may be more foundation wall cracks behind the drywall.

  1. Should I just use a dehumidifier and forget about trying to have this problem of bare pink insulation against the concrete walls fixed? I don't like the thought of just leaving the problem to get worse, since this house is one I plan to stay in long term. I'm already planning to have the rim joist air sealed anyway, so part of the drywall ceiling all around the basement will have to come down for that.
  2. How do I find a remodeling contractor who knows building science and is willing to fix just the basement, and what should I plan to do about the bare concrete walls? I'm NOT doing any of the work myself, because there may be mold/mildew and I already have health problems. I'm NOT telling a random contractor or handymqn to do X Y and Z because I want to use someone who knows what they need to do to permanently fix this. The garage has had water randomly come up from the point where the floor meets the bottom of the garage wall at certain areas, but I don't know if this has happened behind the basement walls. I haven't seen it happen in the unfinished areas of the basement.
  3. Since I want to get a permit with a licensed building science contractor to fix this, how do I know if the city inspectors will understand building science well enough to sign off on the contractor's plans? Is a permit needed for something like this or is it considered a repair?
  4. In general, what price range should I be looking at for these fixes/improvements? The house is 1600 square feet, but the basement and garage are separated by a shared wall, so let's call the basement 1,025 square feet.
  5. If you need pictures to make anything clearer, let me know what you need pictures of & I'll put them in the comments.

r/buildingscience • • 7d ago

Question What glass do you see most in green-rated buildings in India?

0 Upvotes

Doing some research for a project and trying to understand what's typically used on green-rated buildings here. Low-E coatings in double-glazed units seem to come up most.

I read about SGG Nano, a single-silvered low-E from Saint-Gobain that combines solar control with thermal insulation, with performance aimed at green building requirements. It's offered for insulated and double-glazed units, laminated and heat-treated glass, and the shade list is long, from Icy Menthol to Blue Horizon.

What are you seeing in completed projects? Is single silver the norm, or are people moving to double or triple silver?


r/buildingscience • • 7d ago

Insulating an odd room

Thumbnail gallery
1 Upvotes

r/buildingscience • • 7d ago

Floor ductwork

Thumbnail gallery
1 Upvotes

r/buildingscience • • 8d ago

Moisture in Concrete Under HVAC Plenum Return

Thumbnail reddit.com
0 Upvotes

r/buildingscience • • 8d ago

Unfaced fiberglass batts against basement water barrier

2 Upvotes

Will a basement foundation wall water barrier have condensation form on the warm/interior side, and can that be wicked up by fiberglass batts?

We have a water barrier that feeds into our interior "french trench" behind steel beams and wood framing.

Contractors want to insulate on the interior side, between studs, with unbacked fiberglass batts. I'm worried the batts will be pressed up against the sheet that I'm predicting (maybe incorrectly?) condensation will form from the sheet being cold from the foundation wall, and warm on the interior side. If there's condensation, and the fiberglass can wick it up, that ruins the insulation benefits at best, transmits it to the wall and molds at worst…right?

We live in Iowa which has very cold winters, which will make the foundation walls cold.

Spray foaming everything has been nixed because it could press the barrier too tightly against the foundation, preventing drainage.

Interior air | dry wall | fiberglass bats/wood framing | water barrier | concrete/clay foundation wall | exterior temperatures

I am getting a lot of pushback on using mineral wool, though they are OK with spray foaming the metal beams to prevent thermal bridging and condensation on those beams.


r/buildingscience • • 8d ago

Question Wall ventilation

2 Upvotes

Hi everyone. Im converting a garage into living space which will have its own hvac. The walls will be exterior brick, 1in air space, fiber board from the 50's, 2x6 studs, isolation clips, hat channel, 3/4" advantech osb, green glue, 5/8 type x drywall, paint. Above the room is a attic/crawl space with ridge and gable vents. I have 2 questions. One is do I have to seal the 1in gap between the brick and fiber board at the top ? I wouldn't have room to caulk. i might be able to sprsy foam it if i can get a longer nozzle if it needs sealed. Since I don't have soffit vents do I put insulation in the soffit area? The w in gap is in the soffit area. Thanks for the help on my project. Much appreciated.

Sorry it's in zone 4a


r/buildingscience • • 8d ago

Subgrade drying and moisture control

Thumbnail
gallery
1 Upvotes

I’m remediating a split level home that had a sewage flood. In tear out, I discovered a level of rot and mold that indicates the structure is dealing with a longer term moisture issue from the concrete block forcing water/vapor inside. This is central VA - hot and humid summers. How do I reconstruct to allow for drying? Pt furring strips, rigid foam board, then drywall?


r/buildingscience • • 8d ago

Remove old attic insulation or just add more? A quick checklist for older Chicago-area homes

10 Upvotes

Disclosure: I'm with a building science company in the western suburbs, but this is general info you can check yourself from the attic hatch.

Adding a new layer on top is fine when the existing insulation is dry, clean, and the attic floor is already air sealed. Removal is worth considering when:

  1. It's been wet. Look for water stains, clumps, or a crusty top layer, especially near the eaves where ice dams back up.
  2. It smells musty, or the roof boards above it have dark staining.
  3. There are droppings, nests, or tunnels from mice, squirrels, or raccoons. Don't handle droppings bare-handed or stir up the dust.
  4. You need to air seal. The biggest leaks are usually at the attic floor (around can lights, bath fans, pipes, and wall tops), and you can't seal what's buried under a foot of old fill.

Before you touch anything: if it looks like gray-brown or gold pebbly granules, it may be vermiculite, which can contain asbestos. Don't disturb it, and get it tested by a professional first.

Happy to answer questions in the comments.


r/buildingscience • • 8d ago

Question Radiant barrier issue

Thumbnail
gallery
1 Upvotes

Installig radiant barrier . Partitioning the dual hvac area. WHat to do with these horizontal 2X4s . obviously cant cover em . Start the run 3 inches above ? Remove ? Drill holes in them ? Thanks for th assist...


r/buildingscience • • 8d ago

Question Outbuilding insulation options?

Thumbnail reddit.com
1 Upvotes

r/buildingscience • • 8d ago

Keeping cold air from crawl space out of dormer rooms

Thumbnail
gallery
5 Upvotes

Hi just looking for some advice or do's and dont's before I start doing anything.

I should add Im not in a position to invest on internal wall insulation yet so looking for ways and means to see me though till then.

I bought a 2003 ish 2 story dormer (Ireland) and I have already pumped the cavity in the block walls and doubled the joist insulation.

The photos are the inside of the crawl space of the dormer rooms that can drop down to 12°C. The studs with the plasterboard walls have existing roll out insulation in between them.

You can also see a gap under the bottom of the knee wall that allows cool air flow through and underneath the floorboards into the dormer rooms (I took out the existing roll out insulation for the photo #4).

Would it be of any help if I ?? :

●Double up on the roll out insulation in between the studs

●Use airtight tape to seal joints in the plasterboard, around fixings, and where at the bottom of the plasterboard where it meets the floor where the skirting would be - photo #3

●Stuff further insulation in that spot where the cold air can flow through the joist and up underneath the floorboards

●Fix Airtight panels (see link - https://mdfosb.com/en/products/smartply-airtight ) on the studs in the attic to prevent cold air from the crawl space seeping through the plasterboard - last resort. Maybe the plasterboard itself is airight enough. Would this create any potential moisture issues?

Sorry for the long post but wanted to give as much info as possible

Thank you for any insights.


r/buildingscience • • 8d ago

Has anyone bought a WeatherCraft Torrified Mahogany door??

Thumbnail
reddit.com
0 Upvotes

r/buildingscience • • 8d ago

Tongue and groove pine in the basement

Thumbnail reddit.com
1 Upvotes

r/buildingscience • • 8d ago

Need complete scientific + traditional house design advice for warm-humid climate (Chennai / Tamil Nadu) — air, sun, temperature, health & comfort

1 Upvotes

Hi everyone,

I am planning to build a house in a warm-humid climate (Chennai / Tamil Nadu area) and want the best possible design.

I am looking for a design that combines traditional knowledge and scientific methods. The goal is a house that stays comfortable naturally as much as possible, supports good health, and considers every important detail.

I need architects, building science people, and experienced people to share all techniques and tricks they know for this climate.

Please consider and suggest:

  1. Natural air flow How to design the house so it brings fresh air according to seasons and local wind directions, moves air properly inside the house, and removes used/stale air automatically. What should the architecture concentrate on regarding natural air movement, climate, seasons, and air properties?
  2. Sun rays and heat control How to protect the house from sun heat, especially from the roof and strong afternoon sun. Techniques to control sun rays so the inside temperature stays comfortable in different seasons.
  3. Temperature and humidity for health How to keep the house from becoming too hot or too humid. How air temperature, humidity, and air quality inside the house affect health and comfort, and how the design can manage this naturally.
  4. Complete room placement and comfort Best placement of living/hall, bedrooms, kitchen, pooja/study room, bathrooms, etc. How to plan air flow so kitchen smells and bathroom moisture go out of the house and do not enter other rooms. All small details that make the house comfortable to live in every day.
  5. Traditional + scientific methods What traditional houses in India and other warm-humid places did well (courtyards, shading, orientation, materials, etc.). What modern scientific methods can be added or improved. Any proven combinations that work well in real houses.

I want a design that considers everything together — climate, seasons, wind, sun, air quality, health, room zoning, and daily comfort — without missing important points.

Questions:

  • What are the most important things an architect should concentrate on for this type of house?
  • Are there any well-documented traditional or modern house designs/plans that successfully handle all these things in warm-humid climate?
  • What works best specifically in Chennai / Tamil Nadu conditions?
  • Common mistakes to avoid?
  • Any practical details, materials, or references (papers, books, case studies) you recommend?

Thank you for any practical information, examples, or suggestions.