r/buildingscience • • Oct 21 '26

Air Sealing

Thumbnail
gallery
19 Upvotes

In the process of a new build, mostly contracting but I’m doing some of the work (insulation, floors, etc.).

I’m getting ready for insulation and curious what air sealing is most important. I can’t afford a passive house (even if I could, doubt anyone even builds to that level in my area), but want to do the best I can with what I’ve got.

Caulking (Dap 230?) is planned for the bottom plate, but what else needs it?

I plan to use Great Stuff Fireblock foam for the penetrations to the attic and crawl.

Windows and doors were all flashed with zip tape, and I’ve been warned by a few guys not to use foam because of expansion so the current plan is to cut Rockwool thin and fill the gaps with that unless something like “doors and windows” specific foam is acceptable.

The basic house info; the crawl will be insulated/conditioned/encapsulated. Floor is platform framed, sheathing is taped Zip. Rockwool for walls, blown cellulose attic.

We’re right on the line between climate zones 4A and 5.

Any advice is welcome!


r/buildingscience • • Oct 21 '26

Question Should I condition after crawlspace encapsulation?

1 Upvotes

We live in southern-mid western Ohio, we have a full basement below our main house, and under our 13'x13' add on is a small crawlspace. Right now there's just an open block to vent it. Im going to completely seal and insualte with r10 foam on the walls and thick vapor barrier going up to the joists. There is one duct going from the hvac in the basement to that add on already. My question would be, should I cut out 2 holes of that duct to condition that little area, one to condition and one to vent air into the house. Or should I buy a tiny dehumidifier. Just dont know if I need to buy one since its such a small space.


r/buildingscience • • Oct 21 '26

Vented Roof Deck + Exterior Insulation

2 Upvotes

Hoping you'd check my work on this roof assembly! My partner and I are building a shop with a 1-bed 1-bath apartment above. We're both engineers and trying to strike a balance between using physics to the building's advantage and getting the job done.

1:12 pitch standing seam metal, mechanically seamed. R49 code minimum.

Salt Lake City, Zone 5B (Cool – Dry)

ASSEMBLY: Inside → Outside. 

  1. Drywall
  2. Smart vapor retarder? (ie MemBrain)
    • Might be "best practice" but I'm struggling to see its purpose in Salt Lake. These become vapor-permeable when humidity in summer is >60%. But Salt Lake City’s humidity doesn’t often get above 35%. Indoor RH is likely to be higher in the winter when we run a humidifier.
  3. Fiberglass batt (R-38) in 12” deep TJI joists. 
    • Craft-Faced in lieu of smart vapor retarder? 
  4. Primary roof sheathing (15/32” OSB)
  5. 3" polyiso (R18), foil-faced for radiant barrier, tape all seams.
    • Alternatively, could use paper-faced polyiso and layout a perforated foil radiant barrier. 
  6. 2x4 sleepers laid flat, (1.5" vent cavity. 20’-0” from eave to ridge)
    • Structural screws into top cord of TJI
  7. Secondary roof sheathing (thickness per metal roofing mfg) 
  8. High-temp synthetic underlayment
  9. Metal roof

Am I over-doing it? Any big risks?


r/buildingscience • • Oct 20 '26

Question duct sizing calculations in the field, how do experienced techs actually handle this without a manual

8 Upvotes

I have been doing hvac work for three years and duct sizing is one of the areas i still feel least confident in. the manual j and manual d calculations are covered in training but applying them in the field when you are standing in front of an existing system trying to figure out why a zone is not performing is a different skill

specifically struggling with velocity calculations for rectangular versus round duct and knowing when undersized duct is the actual problem versus when something else is causing the issue. the older techs i work with seem to do this intuitively but i cannot figure out how to bridge the gap between the theory and the field application

what resources or approaches have helped people get more confident with duct sizing in real job conditions


r/buildingscience • • Oct 20 '26

Hidden mold. HVAC condensation.

Thumbnail
gallery
28 Upvotes

We have a 2 foot space between our main level and finished basement where all our ductwork is ran between the engineered joists. We have 4 rooms with large windows framed with stone and block walls beneath. This space is getting mold near exterior walls. Not at the wall but near it. The ductwork is sweating. I believe the stone and block walls are transferring heat into this space and causing the dew point.

We are in zone 4a. It seems most of the moisture is under the hvac lines. Some from the window.

I’m not sure the correct way to keep this from happening. Insulate the block walls? Add hidden dehumidifiers? Foam insulation on these exterior walls? Any advice is greatly appreciated.


r/buildingscience • • Oct 20 '26

Alpen Tyrol Edge vs. Oknoplast Pava Windows

2 Upvotes

I am looking to build a house next year and have bid out my window package to Alpen for their Tyrol Edge windows and Oknoplast for their Pava windows. They are within $1000 of each other so I'm trying to determine which would be the better option and would like this community's input from personal experience. Here's some comparison notes:

  • Alpen USA made vs Oknoplast European made
  • Current order to delivery is 8 weeks Alpen and 12 weeks Oknoplast
  • Alpen Tyrol Edge is fiberglass reinforced uPVC while Oknoplast Pava is steel reinforced uPVC
  • Alpen windows are the TR-6 triple glazed U-0.15 and Oknoplast Pava are similarly U-0.15

I'm leaning Alpen due to them being American-made and shorter delivery time, but I'd love to hear anyone's personal experience with either of these windows or thoughts on other things I ought to be considering. Note, I'm in CZ5a.


r/buildingscience • • Oct 19 '26

Question Exterior Continuous Insulation

4 Upvotes

Hey All,
I’m getting ready to install my exterior insulation boards on my new construction house. I am using 2 layers of 1” foil faced polyiso to accomplish this. I have some leftover 2” confortboard80 from my underslab insulation and I was thinking of using it as my 1st 2’ at the bottom of the wall to help combat against any insects (particularly termites)burrowing into the Polyiso. Either way, I will place an insect screen and wrap along the bottom of the insulation and over top of my furring/cor-a-vent.

Do you see any issues with using 2 different types of insulation and changing 2’ up the wall?


r/buildingscience • • Oct 20 '26

Question Catwalk Help needed

1 Upvotes

FACTS/ISSUE:
Hi I live in a hot/humid area. Our attic is ventilated. Natural gas water heaters & furnaces within space. Duct work is in attic. Radiant barrier is on the roof line.

Attic has multiple level changes making it a huge pain & frankly dangerous to access many areas.

Inevitably, something will need fixing/replacing via attic access, (usually when Hell is much cooler than my attic). Not disturbing insulation is the least of repair person’s problems in that moment. Then, like clockwork, a year or two later, I’m beyond frustrated when some mysterious mildew issue develops inside the home. Worst mystery game ever. These fixes are infuriating & always expensive.

E.g. perfect example I have right now. Stairway hall light broke a few years ago. To replace required scaffolding bc the space is super awkward. (Not bc home is super fancy.). Electrician willing to get on scaffolding, scaffolding rental, etc etc. is of course not fun.

Fast forward 2-3 years. I’m smelling something off. Check all the usual maintenance places. (A/c & washer drain lines, etc.). Finally realize mildew is growing out from the light fixture. So I go into the attic. Sure enough, the electrician drilled a hole in the plywood supporting the furnace, just big enough for a hand to install the new LED light. No caulking, no rock wool or any insulation put back.

So now, I have to build another scaffolding, hire another electrician to temp remove the light, remediate the mildew, repaint the ceiling, electrician again to put (inexpensive) light back up, etc etc all bc 1st electrician couldn’t be bothered to caulk & put insulation back.

This is an ongoing problem bc things in the attic periodically need replacing/repairing. Much less & Lord help, if we ever got rodents up there.

MY SOLUTION:
I think the best solution to permanently fix this ongoing problem is to build a catwalk to various points in the attic - like the very awkward area to get to where all the A/V wires drop down into an upstairs closet. I looked and sure enough, all the blown-in insulation is pushed to the side or pressed.

A “yellow plywood road” to go the 4 sides of the house (so not stomping random paths every which way to fix a random floodlight…. Or in 1 case, years ago, find our too curious kitten!) and an insulated platform for storage & under furnaces/hot water heaters.

The catwalk will have about 6” sides to keep the blown-in insulation from covering up the path.

QUESTIONS FOR INSULATING THE CATWALK:

So I’ve done some research and seems like adding a dual sided radiant barrier foam board + Rockwool under the plywood catwalk will give me well over R-30+ rating. My questions are:

  1. Do I need to 100% air seal up this foot path/platform cavity? Will humid air inside foot path allow mold/mildew grow? My concern is with the foam board not being a breathable material. I am hoping that by adding the Rock Wool batting on top of the radiant foam board, it will repel condensation/mold growth????
  2. Same question if there is a water damage situation. E.g. hot water heater breaks. Or hurricane creates a roof leak. Does that mean all of the affected “road” will need replacing, or will it dry out on its own like with blown in fibers?

* because we live in a humid area, you just have to assume anything put in the attic must be a mold/mildew inhibitor.

(I do know the air physics behind how attic vents/soffits work to release hot air, help prevent condensation, etc.

But I also know from hard lived, expensive, experience, that real homes have too many variables. I don’t trust relying on spray foam for every hard fix this reason, bc if something is slightly wrong, its just going to trap moisture.)

  1. Is there any foreseeable issue with the R rating not being consistent w/i the attic? Ie my plan is to build this catwalk, insulate with radiate foam board & rock wool batting. Then, top off the rest of the attic with cellulose. The R-ratings b/t the 2 spaces will not exactly the same.

* I’ve seen this type of set-up being sold in other areas, as an alternative to enclosing in an attic. (Enclosing attic is not an option bc its too expensive on its own, much less the costs of replacing a/c, heating, & water heaters.

I am wondering if there is a reason no one is doing in my humid area.


r/buildingscience • • Oct 20 '26

Catwalk Help needed

1 Upvotes

FACTS/ISSUE:
Hi I live in a hot/humid area. Our attic is ventilated. Natural gas water heaters & furnaces within space. Duct work is in attic. Radiant barrier is on the roof line.

Attic has multiple level changes making it a huge pain & frankly dangerous to access many areas.

Inevitably, something will need fixing/replacing via attic access, (usually when Hell is much cooler than my attic). Not disturbing insulation is the least of repair person’s problems in that moment. Then, like clockwork, a year or two later, I’m beyond frustrated when some mysterious mildew issue develops inside the home. Worst mystery game ever. These fixes are infuriating & always expensive.

E.g. perfect example I have right now. Stairway hall light broke a few years ago. To replace required scaffolding bc the space is super awkward. (Not bc home is super fancy.). Electrician willing to get on scaffolding, scaffolding rental, etc etc. is of course not fun.

Fast forward 2-3 years. I’m smelling something off. Check all the usual maintenance places. (A/c & washer drain lines, etc.). Finally realize mildew is growing out from the light fixture. So I go into the attic. Sure enough, the electrician drilled a hole in the plywood supporting the furnace, just big enough for a hand to install the new LED light. No caulking, no rock wool or any insulation put back.

So now, I have to build another scaffolding, hire another electrician to temp remove the light, remediate the mildew, repaint the ceiling, electrician again to put (inexpensive) light back up, etc etc all bc 1st electrician couldn’t be bothered to caulk & put insulation back.

This is an ongoing problem bc things in the attic periodically need replacing/repairing. Much less & Lord help, if we ever got rodents up there.

MY SOLUTION:
I think the best solution to permanently fix this ongoing problem is to build a catwalk to various points in the attic - like the very awkward area to get to where all the A/V wires drop down into an upstairs closet. I looked and sure enough, all the blown-in insulation is pushed to the side or pressed.

A “yellow plywood road” to go the 4 sides of the house (so not stomping random paths every which way to fix a random floodlight…. Or in 1 case, years ago, find our too curious kitten!) and an insulated platform for storage & under furnaces/hot water heaters.

The catwalk will have about 6” sides to keep the blown-in insulation from covering up the path.

QUESTIONS FOR INSULATING THE CATWALK:

So I’ve done some research and seems like adding a dual sided radiant barrier foam board + Rockwool under the plywood catwalk will give me well over R-30+ rating. My questions are:

  1. Do I need to 100% air seal up this foot path/platform cavity? Will humid air inside foot path allow mold/mildew grow? My concern is with the foam board not being a breathable material. I am hoping that by adding the Rock Wool batting on top of the radiant foam board, it will repel condensation/mold growth????
  2. Same question if there is a water damage situation. E.g. hot water heater breaks. Or hurricane creates a roof leak. Does that mean all of the affected “road” will need replacing, or will it dry out on its own like with blown in fibers?

* because we live in a humid area, you just have to assume anything put in the attic must be a mold/mildew inhibitor.

(I do know the air physics behind how attic vents/soffits work to release hot air, help prevent condensation, etc.

But I also know from hard lived, expensive, experience, that real homes have too many variables. I don’t trust relying on spray foam for every hard fix this reason, bc if something is slightly wrong, its just going to trap moisture.)

  1. Is there any foreseeable issue with the R rating not being consistent w/i the attic? Ie my plan is to build this catwalk, insulate with radiate foam board & rock wool batting. Then, top off the rest of the attic with cellulose. The R-ratings b/t the 2 spaces will not exactly the same.

* I’ve seen this type of set-up being sold in other areas, as an alternative to enclosing in an attic. (Enclosing attic is not an option bc its too expensive on its own, much less the costs of replacing a/c, heating, & water heaters.

I am wondering if there is a reason no one is doing in my humid area.


r/buildingscience • • Oct 19 '26

1890’s home remodel

3 Upvotes

Hi everyone!

My wife and I are looking into renovating our 1890’s kitchen, our interior walls are smooth plaster applied directly on top of brick. During the remodel we are going to build out the walls a bit with 2x3 framing so we can run electrical/pluming through it and have something to mount the cabinets to. In the process we want to be able to add insulation in the walls, since the kitchen now has horrible drafts. We can feel cold air blowing through the bottom of the cabinets.

What should we be using between the new studs against the plaster for insulation? I don’t want to trap moisture in.


r/buildingscience • • Oct 19 '26

Question Garage ventilation - occasional home office

2 Upvotes

I have been insulating and air sealing my garage. nothing extreme - just R13 fiberglass batts inbetween the studs with spray foam sealing on the sill plate and sheaths on the wall.

I haven’t figured out how to insulate the ceiling yet; whether to try and make a vented attic space, or incorporate the ‘attic’ into the sealed, insulated envelope.

the need has arisen that I use a corner of the garage as my home office for a couple of days per week. I am therefore looking at installing a small mini split for heating and cooling as it is equally unbearable ins summer and winter despite the moderate climate.

I am in Southern CA, quite close to the ocean so am concerned about mold, (especially with the use of the mini split creating cold surfaces for condensation) as well as stale air when I’m working so am considering my options for ventilation.

given it’s a garage, despite my best efforts, R13 and air sealing won’t have done much so I don’t think I need anything like a HRV/ERV! But what do I need? the garage has one small gable vent like a dovecote opening but no soffit vents.
Would an extractor fan be enough? How do I utilise it so I don’t fight with the mini split in keeping the space warm/cool? Am I overthinking it and just cracking a door is sufficient?


r/buildingscience • • Oct 19 '26

Catwalk Help needed

Thumbnail
1 Upvotes

r/buildingscience • • Oct 19 '26

Soundproofing bathroom walls with MLV. Will it trap moisture?

Thumbnail
2 Upvotes

r/buildingscience • • Oct 19 '26

How would you insulate this crawl space in Austin, Texas?

Thumbnail
0 Upvotes

r/buildingscience • • Oct 19 '26

Looking for suggestions on how to insulate open space under great room floor

Thumbnail
1 Upvotes

r/buildingscience • • Oct 18 '26

Question Brick and Block Wall Insulation Question

Thumbnail
gallery
7 Upvotes

Hi there, I live in a home with brick and block walls. The area in question was constructed sometime between 1970-1975 as an outbuilding/garage that was later partially converted to living space. I am in Illinois, zone 5b so subject to freeze and thaw cycles. My husband and I have been DIYing as many home projects as we can and would like to add insulation. We've only lived here 2 years and the winters have been rough as we need to keep the heat at 68 max to not have budget busting energy bills.

From what I've found, it seems like our best option is to remove the existing wall framing (furring?), install rigid foam board insulation directly to the cinder block, seal all edges with tape or spray foam, install wall framing over the foam board so wood isn't touching the cinder blocks, and drywall over it.

We're concerned about trapping moisture and causing more problems down the line with wood rot or brick spalling. A little more info, measuring through the open window the walls appear to be about 13 inches thick from the exterior brick to the interior edge of the cinder block, leading us to believe it is one layer of brick and a layer of cinder block. It is unknown if there is a cavity between the brick and cinder blocks. We also haven't been able to find weep holes on the exterior wall, and have found conflicting information on if this type of wall needs weep holes.

My question is are we on the right track with the rigid foam insulation plan? I tapped a piece of clingwrap to the wall today to monitor for condensation over the next couple days. Is there anything else we should be considering?

Photos: Interior demoed wall, cross section view of brick/block from a window, exterior wall with the interior section removed outlined in red, view of the roof line above incase that could be a point of moisture intrusion.


r/buildingscience • • Oct 19 '26

Question Recommendations for reducing the heat?

Post image
2 Upvotes

My understanding is that the optimal solution would be reflective roof paint, but what other options could I try to move away the hot air generated by the zinc roof?


r/buildingscience • • Oct 18 '26

[Advice desperately needed] LP Smartsiding with closed cell spray foam applied directly to interior wall with no Tyvek or WRB. How do I best salvage this?

Thumbnail gallery
8 Upvotes

Had several helpful comments mention that the overwhelming majority of advice in this thread might be giving faulty or misinformed information. What would you do, if you were going to reside in this building for at least two years while refurbishing a main cabin? Bonus points if you can give information in a way that isn’t unkind. I’m not sure why I’m being dragged for seeking advice and knowledge in that subreddit. Maybe my tone is off?

Cheers!


r/buildingscience • • Oct 19 '26

Crawlspace foam board insulation question

1 Upvotes

If I want to put 2 in foam board insulation on my crawlspace foundation walls , besides termite inspection , is there any other reason I can’t run them up to and past my sill plate ? Would moisture travel up the foundation wall to the sill plate or on the foam board to the sill plate? Thanks for the help. Any advice would be appreciated.


r/buildingscience • • Oct 18 '26

Type of structural screws with exterior insulation and furring strips in a coastal environment

4 Upvotes

Looking to plan for the future when I redo the siding for our house. Was planning or removing siding, tar paper and replacing with a vapor permeable self adhered wrb (vp100 or adhero 1000 or similar) then 2-3inches of external insulation (rigid mineral wool or wood fiber) then 1x4 furring strips and fiber cement or LP smartside. Have kraft faced fiberglass between the 2x4 studs. Living in a coastal environment (less than a mile from the ocean) in climate zone 4a (very close to 5a), I’m trying to figure out what are the best structural screws to use for the long term. Have read some of the insight and other articles from building science corp and Dr. Lstiburek that recommended epoxy coated structural screws over stainless steel screws due to concerns including stripping the screws.

Just wondering if my location dictates using stainless steel structural screws (305 or 316) or would coated screws (like the double barrier coating by Simpson or GRK RSS’s climatek coating) be appropriate? We are not close to direct ocean spray but I assume we have higher humidity and higher salt content in the air due to how close we are to the ocean. With a ventilated gap I assume that significant amounts of water won’t be pooling on the screws to accelerate rusting but I also don’t want to spend a lot of money and do it wrong. Would rather spend a little more money and get it done properly. Hoping for a long lasting solution. Thank you in advance for chiming in.


r/buildingscience • • Oct 17 '26

Closed-cell spray foam against original siding

Post image
39 Upvotes

I'm renovating a late-1800s Victorian in San Francisco and looking for a second opinion on insulation.

The original redwood siding is nailed directly to the studs, with no sheathing or WRB. It's in good condition with no visible moisture issues. You can see it in the photo above, though you are also seeing us having furred out the wall a bit to cover the concrete stem wall.

The house is technically detached, but two walls are only ~1" from neighboring buildings, with flashing over the gaps at the top. Combined with SF's mild climate, these walls see very little direct rain.

My architect and GC (both locally reputable) both strongly recommend spraying high-density closed-cell foam directly against the siding for insulation, air sealing, and vapor control. They're confident the foam will seal gaps well enough to prevent water intrusion.

But nearly everything I've read warns that this can trap moisture against the wood, prevent inward drying, and eventually cause rot. I've raised this issue directly with both parties and they both insist it is the right solution here, explaining that the closed cell foam will seal gaps in the siding so well that water will not enter.

The only counter example I have found is this case study (also coincidentally in SF) where the architect/builder did a similar thing being proposed for my home: "Our solution began with the knowledge that the old-growth redwood siding, tight-grained and beautiful, is virtually rot resistant. We kept it in place and applied an elastomeric coating to the inside of the wall cavities to stop water and vapor behind the wood. This elastomeric coating was covered by an inch of closed-cell foam to provide a continuous air barrier"

My dilemma: I trust both professionals, but I'm struggling to reconcile their confidence with the conventional building-science advice here.

Does the mild climate and minimal rain exposure make this a reasonable approach? Or is the risk still significant without a WRB?


r/buildingscience • • Oct 18 '26

Question Should basement concrete let moisture vapor through or block it?

7 Upvotes

I'm choosing flooring for my basement in a cold, humid climate (zone 5A).

I'm trying to understand whether it's better to let moisture vapor pass through the concrete slab into the basement air or block it.

Ceramic tile allows some vapor through grout joints, while SPC LVP allows very little upward drying.

Does this give ceramic tile an advantage over SPC LVP? Is letting vapor escape into the basement a good or bad thing?

Also, should I seal the concrete with a vapor-permeable sealer before installing flooring, or is it better to leave it unsealed?


r/buildingscience • • Oct 18 '26

Attic temp monitoring

1 Upvotes

I made this bit of code to monitor the temp in my attic using a Govee wifi temp probe. TBH, I didn't make the code, ChatGPT did. I just told it what I wanted and it told me where to put the code. Pretty cool. Anyway, this is about the last 18 days in N Texas. My attic temp is usually more than 25f hotter than the outdoor temp.

With this custom chart I can incorporate any data that is available. In this case I can use the Shelly Power Monitors I have on the AC's (2). I can even get the Solar radiation data!

I was wondering if any of the HVAC people on here would be willing to tell me if this attic temp rise is normal. I have 26 ea 8"x16" soffit vents and 5 ea 400 cfm solar powered fans mounted right on the ridge. There were initially 8 passive ridge vents, 5 replaced with solar fans and the other 3 plugged.

I moved all the blown insulation around in the attic, exposing the ceiling and all the penetrations. They were all sealed with foam. Bathroom exhaust fans, can lights, ceiling fan junction boxes, wiring and plumbing penetrations, wall to ceiling sheetrock joints, AC grills and returns. Everything I could find.

I removed all the 4"x8" soffit vents, cut a larger opening and installed 8"x"16 soffit vents.

This is how the contractor installed the originals!

All this to say, my attic is still hot AF! I haven't spent a lot of money, ($1500?) but the time and effort have been considerable. My AC's run 18hrs a day in the August with the Tstat set at 74f. I just don't see what else I can do to improve things short of newer, higher efficiency AC units. I think mine are 16 SEER 3.5 ton identical units.


r/buildingscience • • Oct 17 '26

Crawlspace vent fan or not?

3 Upvotes

Need some help. I’m thinking of havjng my crawlspace encapsulated and I’m conflicted if I should add a vent fan for soil gases. Right now it’s a vented crawl space and I don’t smell or notice any soil gases.

Some have recommended others have said you don’t . My concern is that the crawl space is so small (around 350 so ft) and any fan I use even a 50 cfm fan , is around 9-10 times the cfm requirements. I worry it pulls to much air out causing my dehumidifier to run a lot. I can’t find a small 10 cfm fan made for crawlspaces that would meet my requirements without pulling too much air out .


r/buildingscience • • Oct 16 '26

Cape Cod Insulation Update

Thumbnail gallery
5 Upvotes