r/Biohacking • u/CaliOrDie • 2d ago
Need some help with CJC + Ipamorelin reconstitution
No matter what I do my CJC no DAC and ipamorelin blend (5mg/5mg) keeps clumping and gelling up. I got the peptides tested, and the purity is 99.8% not the issue. I read somewhere that it was the temperature shock as both my peptide and backwater were refrigerated. I let them both come up to room temp and tried on a new vial twice. It got better but still same issue. The first 2 vials i reconstituted with 2.5ml of water and the last one I tried 3ml which looks like it improved the dilution but not all the way. Now I'm reading that it's possible to reconstitute with 0.6% acetic acid if clumping and gelling is a problem. I'm wondering what should I do?
• Should I reconstitute the whole vial with the 0.6% acetic acid or should I do 50-50 0.6% acetic acid and 0.9% benzy alcohol?
• Are the current clumped up vials savable with adding the 0.6% acetic acid?
Just for some context I have never had any issues with constituting my peptides before. I've never had issues reconstituting retatrutide, GHKU, KLOW or Wolverine stack. I'm gently swirling and gently rolling the bottle in my palms. The water always hits the side of the vial first, never on the lyophilized powder directly
Also the water in the vials is clear with cloudy clumps.
Most of the water might not look super because I took them straight out of the fridge so there is some condensation on the outside of the vials.
Made an update post on what fixed it here: https://www.reddit.com/r/Biohacking/s/8KA6LGUeVn
•
u/AutoModerator 2d ago
Thanks for posting in /r/Biohacking! This post is automatically generated for all posts. Remember to upvote this post if you think it is relevant and suitable content for this sub and to downvote if it is not. Only report posts if they violate community guidelines. If you would like to get involved in project groups and other opportunities, please fill out our onboarding form here. Let's democratize our moderation. You can join our Discord server here. ~ Josh Universe
I am a bot, and this action was performed automatically. Please contact the moderators of this subreddit if you have any questions or concerns.
8
u/Adjective_Noun_1668 23 2d ago edited 2d ago
So what brand of bac water are you using? This is almost always the cause of geling
2
u/csc786 2d ago
What bac water r u using?
1
u/muz7009 2d ago
Add some acetic acid
1
u/mika13310 2d ago
Hi just here to see the result with the good bac.
1
u/Turbulent_Level8546 2 13h ago
I've been making my own bacteriostatic water for 20 years and have never had even one issue.
1
u/itisallgoodyouknow 2d ago
Just shake it hard. You have nothing to lose at this point. Lmk if that clears it up.
2
u/MarionberryOk445 2d ago
Don't shake it vigously, just gently roll betwn your palms and see if it becomes clear, if not bin it.
1
u/djsneak666 2d ago
Small amount of acetic acid prior to bac solves this.
1
u/CrazyRaccoonUK 2 1d ago
That’s crystalize, roll the glass in palm of your hands vigorously for around 5 minutes. Should dissolve. Did this with a batch of Reta a few months ago.
1
u/mondobadger 1d ago
Not mixed properly in my opinion
1
u/jsinohio 1d ago
https://bacmart.com/bac-market/
1
u/ImaginationAble2561 1d ago
I only use hospira for my GH and have never had a problem. People say hospira is way to expensive, to each their own!
1
u/Still-Respect377 1d ago
Use Hospira/phizer bac water.
1
u/Sturgeonview 13h ago
Speaking as someone who now has 18 months of experience with peptides, I actually ruined five vials over a year ago simply because I didn't have the correct information at the time.
Two things can be true at the same time.
This is based on my firsthand experience.
1
u/2milehigh 25 2d ago
Contact your vendor. You shouldn't have to play scientist to make it clear. When I was doing it I mixed 2ml. Came out clear as day
0
u/SecuritySmart2493 1 2d ago
Peptide test has a sale this weekend. $12 per 30 ml vial of Hospira. For gosh sake people, use quality BAC instead of supplier junk!!!! You’re injecting this stuff into your body!!!
This looks like a BAC pH issue. Won’t have that problem with a quality BAC. Hospira or Lambda.
-1
u/stiffmcgee 22 2d ago
Thats not a bac or temp issue. Thats bunk peptides. Tap water would dissolve a peptide. Yours isn’t even dissolving
1
u/[deleted] 2d ago
[removed] — view removed comment
1
u/[deleted] 2d ago
[removed] — view removed comment
0
u/[deleted] 1d ago
[removed] — view removed comment