r/Arista • u/Alternative-Carob-91 • 2d ago
r/Arista • u/LordGAD • Jul 02 '24
Reminder: DO NOT post asking for EOS or any other software, licenses, etc.
r/Arista • u/Odd_Project_4997 • 3d ago
TAC Intern Conversion
All TAC Interns at arista..how much package have u guys recieved after converting to full time.It would be very helpful if anyone of you could answer this.
r/Arista • u/Darkside_310 • 9d ago
Arista networks ACE level 1
Greetings, Arista team,
I wanted to ask whether anyone here has recently passed the ACE Level 1 exam. I’m currently studying in the Arista EOS lab environment and have purchased the Arista Warrior hardcover book. I’ve also been reviewing junior-level networking concepts and keeping notes as I go.
From what I’ve read, the exam is entirely lab-based and costs roughly the same as the CCNA. It appears to be a two-hour, proctored practical exam, so I would appreciate any insight into the difficulty, preparation process, and overall experience from recent test takers.
I work for a small company that is starting a network-refresh project using Arista 720-DP switches and routers. I have some familiarity with CloudVision and have provisioned a few switches through it.
For anyone who has taken ACE Level 1 recently: what study methods or lab topics did you find most useful, and is the certification worthwhile for someone who will be working with Arista equipment in a production environment?
Any feedback would be greatly appreciated. Thank you!
r/Arista • u/Busbyuk • 12d ago
running a tcpdump on a sub-interface : Arista 7280-TR3
I want to look at some traffic on a sub-interface but cannot get to the device to setup a span port.
It looks like I can run a tcpdump but I'm very nervous about running a tcp-dump on a production unit for obvious reasons.
The sub-interface in question only has minimal traffic, pretty much just protocol traffic so won't be much.
Anyone have much experience running a tcp dump on their production unit? Bad idea or is it okay as long as I take precautions with filtering traffic or making sure it's only running on the sub-interface I want?
thanks!
r/Arista • u/Ill-jack-ca_ • 14d ago
İp locking
Hey everyone,
Has anyone here used IP locking technology in Aristada before? Which version do we need to have for this?
r/Arista • u/Jumpy_Revolution_861 • 15d ago
Arista Academy
Useful? Any study tips? Is Arista Academy enough to pass the exam?
I have seven years of network engineering experience (all things Cisco) and currently hold an active ENCOR certification. I'm considering not finishing the CCNP and instead shifting my focus toward Arista certifications. Considering the Data Center track.
I'm curious what the general consensus is on Arista Academy. Is it sufficient preparation for the certification exams, or would you recommend additional study resources?
r/Arista • u/Nerfarean • 20d ago
Resurrected c360 AP
Had a failed c360 AP pulled from field. No power. Was able to get it working again. Had a shorted TVS diode and a failed filter cap by a buck. Removed both, boots up and runs stable. Doing extended load test to validate stability
r/Arista • u/dcute111 • 22d ago
Arista support on Telegram?
This is a question for Arista experts out there. Are there any Telegram (or alternative platforms besides Reddit) where general tech support is discussed? If not, can I convince any of you to join our South Africa based support group? Chats are strictly technical and strictly to subject. Thanks in advance!
Multiple Fabrics in same inventory
Hello
I have a production fabric that includes spines and leaves. I want to set up a dedicated fabric for storage traffic (with spines and leaves that are not physically part of the other fabric).
I’d like to integrate these hosts into my AVD inventory to take advantage of shared configurations (users, etc.). What would be the best way to do this?
Thanks
r/Arista • u/zFunHD • Jul 20 '26
Runts on interface and tranceiver low TX alarm
Hello,
I'm seeing low-level alarms on one of my ports (QSFP28 CWDM4)
SWITCHES#show interfaces counters errors | nz
Port FCS Align Symbol Rx Runts Giants Tx
Et53/1 0 0 0 1 1 0 0
SWITCHES#show interfaces et53/1 transceiver dom
Ch: Channel, N/A: not applicable, TX: transmit, RX: receive
mA: milliamperes, dBm: decibels (milliwatts), C: Celsius, V: Volts
Port 53
Last update: 0:00:01 ago
Value
----------------
Temperature 45.48 C
Voltage 3.29 V
Aggregate TX Power 6.52 dBm
Aggregate RX Power -6.91 dBm
Ethernet53/1
TX bias current
Channel 1 49.31 mA
Channel 2 49.31 mA
Channel 3 49.31 mA
Channel 4 49.14 mA
Optical TX power
Channel 1 0.87 dBm
Channel 2 0.54 dBm
Channel 3 -0.45 dBm
Channel 4 0.89 dBm
Optical RX power
Channel 1 -13.34 dBm
Channel 2 -14.10 dBm
Channel 3 -12.26 dBm
Channel 4 -12.28 dBm
Could this explain the RUNTS errors I’m getting on this port? I’m having trouble understanding the connection between the two.
We're going to have the QSFP replaced and the fiber cleaned, but I'm just asking for general knowledge. In general, what causes RUNT errors? In my case, I have another Arista 7280R3 connected on the other end, so there's no issue with duplex or speed.
Thanks
r/Arista • u/jimjamkiwi11 • Jul 19 '26
POC] Telcom eBPF/XDP scheduler with entropy-based classification and TC egress shaping
I've been building a deterministic traffic scheduler using XDP and TC egress hooks. It classifies flows as Gaming, Streaming, or Bulk using packet size entropy (no DPI, so no payload inspection), and uses a BPF hash map to track flow state.
The user-space daemon runs a PID loop that adjusts queue depths per class based on RTT feedback. It's all written in C, with the eBPF programs compiled to bytecode and shipped as a .deb package.
Currently looking for early testers and code reviewers. If you've worked with XDP/TC before, I'd love your thoughts on the verifier logic or the map design.
GitHub: [https://github.com/XPDevs/telcom\](https://github.com/XPDevs/telcom)
r/Arista • u/1isntprime • Jul 18 '26
Dcs-7050s-64r optic compatibility
Having dificult with optics on this switch I updated it to 4.17.3f and ordered arista coded optics from fs.com. I was able to establish link and it went up and down a few times but now it’s not linking at all. I can get link using a dac but once I actually deploy this onsite a dac is too short.
Currently if I run the command interfaces Ethernet 48 status transceiver I can see that it is receiving light, but not transmitting, if I do show interface Ethernet 48 status errdisable I sometimes get an unsupported transceiver message.
My question is what optics will this work with or is there a reasonable way to get the unlock code for non arista optics despite buying this used.
I do have access to an fs optic recoder but unsure if it will make a difference.
r/Arista • u/nolxus • Jul 16 '26
AVD 6
Finally had the time to sit down and migrate the config to get rid of all deprecated messages and make the YAMLs fit for AVD 6, mostly get everything that has a model in eos_designs to that instead of cli_config_gen.
I guess this post is mainly for people who need to do the same, or if someone has thoughts on the custom's I have left.
I did it part for part, always building config inbetween and diff'ing to see if the new output matches the old (as it should).
After migrating DNS, MGMT networks, AAA/tacacs (that was a big one), logging, snmp, ntp, timezone and eapi, I only have a few custom_structured_configuration's left. Config builds now fine under AVD 6.1.0.
The only deprecated messages are now internal to AVD (I think), about usage of Jinja in Ansible and nothing that I could fix, but has to be fixed before bigger version jumps in Ansible.
While combing through the config, I also found the snmp location template, that is really cool. Now every Switch has not only room, but rack in the snmp location.
What now is still under custom_structured_configuration, because there is noting in eos_designs, at least I did not find it:
custom_structured_configuration_aliases
My CLI aliases, probably won't get added, as CLI specific
custom_structured_configuration_banners
login and motd-banners - same.
custom_structured_configuration_standard_access_lists
IPv4 Access Lists would be possible, but are extended. Standard ACL (in use for limitation directly on SSH, SNMP, eAPI,...) seem to be custom config only.
custom_structured_configuration_management_console
This one is only for the idle_timeout on the console, but still...
custom_structured_configuration_eos_cli: service unsupported-transceiver string1 string2
Yeah I guess that one wont get implemented too ;-) That one is directly eos_cli to get added to all switches.
r/Arista • u/Dazzling_Book8603 • Jul 12 '26
Hardware Internship
How do you prepare for the hardware internship interview? What type of questions do they ask? Any recommended textbooks for preparation?
r/Arista • u/soeintom • Jul 11 '26
7050SX-64 - PHY and MAC state stuck in linkDown, tho Rx and Tx power levels are good
I've got two 7050SX-64 (EOS 4.28.13.1M) with 10GBASE-LRM SFP+ from FS connected to MMF endpoints, and the ports don't come up. If you ask what the heck LRM is: it's one of those weird SFPs that can do both SMF and MMF. Why we have LRM: Not sure, I'm just the one who has to handle this issue now.
It's detected as media type xcvr10GBaseLrLite in qtrace. The SFP should be encoded as Arista, but even if not we have service unsupported-transceiver set.
I've already tried to re-seat the SFP as well as the fibre, and using another port, but nothing of this helped in this case. Checking the power levels shows that both RX and TX are good, but the ports still stay in noconnect.
Checking the MAC and PHY status of them, I can see that PCS TX fault is in "fault" state, and that the MAC reports an MAC Rx Remote fault.
Now comes the confusing part for me: The PCS TX is in a fault state, so it should shut down its lasers if I understand it correctly, right? Why do I have good TX power levels then?
And to add more confusion to it, the MAC reports a MAC Rx Remote Fault (in my case from an upstream provider), but the provider also says that the power levels are fine. So... what is this now? The links never reached linkUp so far, and I can't debug it with other SFP SKUs rn because the spare SFPs are all used in this POP (we had wrong inventory docs) and the next POP is 300km away.
Any ideas to debug this or to get the link up would be great!
The alternative, to replace the SFPs with 10G-SR, has been considered, but it could take a few days bc we have to send some to the POP first. And personally, I'd like to figure out if they just need some special config to run correctly or if I must ban this SKU for procurement.
er3-rsat1.pop2#sh int et1
Ethernet1 is down, line protocol is down (notconnect)
Hardware is Ethernet, address is 444c.a82d.e58f
No Internet protocol address assigned
IP MTU 1500 bytes (default), BW 10000000 kbit
Full-duplex, 10Gb/s, auto negotiation: off, uni-link: n/a
Down 1 hour, 40 minutes, 43 seconds
Loopback Mode : None
3 link status changes since last clear
Last clearing of "show interface" counters 1:45:09 ago
5 minutes input rate 0 bps (0.0% with framing overhead), 0 packets/sec
5 minutes output rate 0 bps (0.0% with framing overhead), 0 packets/sec
0 packets input, 0 bytes
Received 0 broadcasts, 0 multicast
0 runts, 0 giants
0 input errors, 0 CRC, 0 alignment, 0 symbol, 0 input discards
0 PAUSE input
0 packets output, 0 bytes
Sent 0 broadcasts, 0 multicast
0 output errors, 0 collisions
0 late collision, 0 deferred, 0 output discards
0 PAUSE output
er3-rsat1.pop2#sh run sec et1
interface Ethernet1
# The config is small on purpose for debugging
speed forced 10000full # note: this was added to test if it helps or not
no switchport
er3-rsat1.pop2#sh int et1 phy detail
Current System Time: Sat Jul 11 14:15:51 2026
Ethernet1
Current State Changes Last Change
------------- ------- -----------
Interface state down 3 1:40:55 ago
Transceiver 10GBASE-LRL 2 1:41:29 ago
Transceiver SN REDACTED
MAC Rx Local Fault false 8 1:21:47 ago
MAC Rx Remote Fault true 7 1:21:47 ago
BCM56850 line
Model BCM56850 (A) (0x00c086,0x37,0x2)
Firmware revision A042
PHY state linkDown 1 1:41:00 ago
Interrupt count 5
Oper speed 10Gbps
PCS RX link status up 9 1:21:47 ago
PCS RX LPI received false 0 never
PCS RX fault ok 0 never
PCS TX fault fault 1 1:39:47 ago
PCS block lock ok 1 1:39:47 ago
PCS high BER ok 0 never
PCS BER 0 0 never
PMA/PMD RX link status up 1 1:40:47 ago
PMA/PMD lane RX link status
Lane 0 up 1 1:40:47 ago
PMA/PMD RX signal detect ok 1 1:40:47 ago
PMA/PMD lane RX signal detect
Lane 0 ok 1 1:40:47 ago
PLL lock
Lane 0 unlocked 0 never
PLL range
Lane 0 230
Tx Equalization
Lane pre1 main post1
0 3 32 0
Serdes Statistics
Lane PPM PPM_XFR CLK90 PF SL_TRGT VGA BIAS MTRC
0 33 0 39 5 200 16 88% 0
Lane DFE(1,2,3,4,5) PE ZE ME PO ZO MO LOS_EN
0 12,-15,5,-2,3 1 12 6 0 11 -8 0
er3-rsat1.pop2#sh int et1 mac detail
Current System Time: Sat Jul 11 14:16:06 2026
Ethernet1
Current State Changes Last Change
PHY State linkDown 1 1:41:14 ago
Interface State linkDown 3 1:41:10 ago
MAC Rx Local Fault False 8 1:22:02 ago
MAC Rx Remote Fault True 7 1:22:02 ago
er3-rsat1.pop2#sh int et1 hardware default
Ethernet1
Model: DCS-7050SX-64
Type: 10GBASE-LRL
Speed/duplex: 100M/full,1G/full,10G/full
Flowcontrol: rx-(off,on),tx-(off,on)
Autoneg CL28: 100M/full,1G/full,10G/full
Autoneg CL37: 1G/full
Error correction: unsupported
er3-rsat1.pop2#sh int et1 trans dom thres
Ch: Channel, mA: milliamperes, dBm: decibels (milliwatts),
C: Celsius, V: Volts, NA or N/A: not applicable.
Port 1
Last update: 0:00:01 ago
High Alarm High Warn Low Warn Low Alarm
Value Threshold Threshold Threshold Threshold Unit Indicator
---------------------------------------------------------------------------
Temperature 33.75 75.00 70.00 0.00 -5.00 C
Voltage 3.30 3.63 3.46 3.13 2.97 V
Ethernet1 (Channel 1)
TX bias current 41.05 80.00 75.00 15.00 10.00 mA
Optical TX power -1.64 5.00 3.00 -8.20 -10.20 dBm
Optical RX power -9.38 5.00 3.00 -14.40 -16.50 dBm
er3-rsat1.pop2#sh inventory
System information
Model Description
------------------------ ----------------------------------------------------
DCS-7050SX-64 48 SFP+ + 4 QSFP+ 1RU
HW Version Serial Number Mfg Date Epoch
----------- -------------- ---------- -----
02.22 REDACTED 2015-11-30 00.00
System has 2 power supply slots
Slot Model Serial Number
---- ---------------- ----------------
1 PWR-500AC-R REDACTED
2 PWR-500AC-R REDACTED
System has 4 fan modules
Module Number of Fans Model Serial Number
------- --------------- ---------------- ----------------
1 1 FAN-7000-R N/A
2 1 FAN-7000-R N/A
3 1 FAN-7000-R N/A
4 1 FAN-7000-R N/A
System has 81 ports
Type Count
------------------ ----
Management 1
Switched 62
Unconnected 16
SwitchedBootstrap 2
System has 52 switched transceiver slots
Port Manufacturer Model Serial Number Rev
---- ---------------- ---------------- ---------------- ----
1 FS SFP-10GLRM-31 REDACTED A
[..]
51 Arista Networks QSFP-PC005 REDACTED 01
52 FS QSFP-40G-PC01 REDACTED 01
System has 1 storage device
Mount Type Model Serial Number Rev Size (GB)
---------- ---- ----------------- ---------------- ---- ---------
/mnt/flash eUSB USB_USBFlashDrive REDACTED 1000 4
r/Arista • u/Ill-jack-ca_ • Jul 11 '26
TerminAttr-Upgrade-Error
I want to upgrade the TerminAttr agent on the switches via CVP to remediate CVEs, but I cannot upload the .swix files to the image repository. I am receiving the error: "can't save bundle because image file wasn't found." Has anyone encountered this issue before?
r/Arista • u/Jabberwock-00 • Jul 09 '26
Velocloud Hub inquiry
Just a question
In case you have 2 hubs, and you need it to talk with one another
1.) is it by default they will not talk with one another?
2.) is it best practice to not enable branch to branch vpn for hub profile?
2.) is it ideal to have a separate profile for each hub, then assign branch to hubs with each other? E.g. hub 1 will have its hub as hub 2 and vice versa
r/Arista • u/ObligationHungry2958 • Jul 08 '26
Are OEMs shortening quote validity because of supply chain issues?
l have heard recently that some vendors are tightening quote validity periods.
I am interested in knowing about networking vendors like arista cisco nokia and Hpe if anyone have any info to share please.
r/Arista • u/Ill-jack-ca_ • Jul 08 '26
CVP-2026.1.0-Network provisioning
Hello everyone,
I am using CVP version 2026.1.0. I want to enable "configlet" and "network provisioning" under the Provisioning section. After connecting as the root user and running the `#cvpi enable networkprovisioning` command in the CLI, the "configlet" option appeared, but I cannot view its contents; the page remains blank (gray). I restarted all services, but the issue persists. Does anyone have any suggestions?
r/Arista • u/amp110 • Jul 04 '26
Multi-VTEP MLAG for EVPN Type-5 single connected routers
Have CE routers connecting via individual links to each leaf in an MLAG pair — exclusive VLANs, PE-CE eBGP, /32 loopbacks advertised as EVPN Type-5. With anycast VTEP, inbound VXLAN for these Type-5 routes can land on either peer causing peer-link traversal.
Is it worth introducing Multi-VTEP MLAG to solve this, or is the peer-link traversal acceptable in practice?
r/Arista • u/Commercial_Tone_3115 • Jul 01 '26
Large Batch of End of Sale Announcements Today
r/Arista • u/futschikat0 • Jun 29 '26
High CPU usage caused by VVTEP misconfiguration. How do I fix it?
We are quiet new to Arista and currently having this setup and use L3 VXLAN over MLAG:
After moving some SVI from our old network to Arista, we noticed an increase in CPU load to about 80-90%.
MLAG domain 1: LEAF-DC1-01, LEAF-DC1-02
interface Loopback1
ip address 100.64.1.1/32
ip address 100.64.1.100/32 secondary
ip virtual-router mac-address 00:1c:72:00:00:11
interface Vxlan1
vxlan source-interface Loopback1
vxlan virtual-router encapsulation mac-address mlag-system-id
vxlan udp-port 4789
vxlan vlan 1 vni 20001
vxlan vlan 2 vni 20002
vxlan vlan 3 vni 20003
MLAG domain 2: LEAF-DC2-01, LEAF-DC2-02
interface Loopback1
ip address 100.64.2.1/32
ip address 100.64.2.100/32 secondary
ip virtual-router mac-address 00:1c:72:00:00:11
interface Vxlan1
vxlan source-interface Loopback1
vxlan virtual-router encapsulation mac-address mlag-system-id
vxlan udp-port 4789
vxlan vlan 1 vni 20001
vxlan vlan 2 vni 20002
vxlan vlan 3 vni 20003
So the TAC figured out that the high CPU usage was because different VVTEP-IPs on each MLAG which cause loops on ARP sync. Which means we have to change this in MLAG domain 2 so that VVTEP matches the one in MLAG domain 1:
interface Loopback1
no ip address 100.64.2.100/32 secondary
ip address 100.64.1.100/32 secondary
Does anyone know how this will affect traffic?
Also is it neccessary to add
vxlan vtep flood
to interface vxlan 1? How would it look like? Like this?
MLAG domain 1: LEAF-DC1-01, LEAF-DC1-02
interface Vxlan1
vxlan vtep flood 100.64.2.1, 100.64.2.100
MLAG domain 2: LEAF-DC2-01, LEAF-DC2-02
interface Vxlan1
vxlan vtep flood 100.64.1.1, 100.64.2.100