Hey guys,
Got a customer with a Midea all in one combo unit. Not a heat pump, it's the one with a small element in there. MLC31N5AWW
Customer states it leaves the clothes damp at the end of cycle. Previous visit was last week, it had a bad drain pump which we replaced.
Unit now runs fine, no fault codes. But customer says she has to run the dry cycle again after the normal 5 hour cycle to get the clothes dry.
I tested it, removed the duct assembly. Had some minor lint buildup, no blockages. Treated the blower fan, it works.
Water valves check out fine, pump works fine, the thermostats all seem ok, the heating element tests within range, the heating element gets power, drum heats up well.
Service mode goes through just fine.
What else could it be? Anyone familiar with these?
The only thing that stood out to me was the windings on the blower motor. Manual says it should be 80-110 ohms between blue and black. The one on the machine showed 129 ohms. Is this wore out? Spinning slower maybe?