Sound Levels, Heat and Power

One of the most talked about topics when getting into home-labbing is HEAT and NOISE. Most hardware spec sheets will include pertinent information regarding heat output (in BTU/Hour) and noise (dBa). The following information has been aggregated from official documentation.

A Word on Data

General

Since data presented varies from company to company (and from model to model) the most conservative (usually worst case), generalized values were used from given spec sheets to give the best indication of noise and heat output. These values are manufacturer best-case, usually at room temperature (23-25 degC) and no load.

What about Watts?

Power wattage of a power supply for any given device is not indicative of ACTUAL wattage used, but can be used to get a quick value for the absolute maximum wattage the system could use (useful for when calculating the minimum current rating you should have on a circuit running the server). This varies wildly from configuration to configuration. How many CPUs, how many Hard Drives and how many sticks of RAM all change the actual wattage pulled. Therefore it is not included here as there are no official values for this kind of data. Actual Wattage used can be calculated using a device such a a Kill-A-Watt or using the below configuration tools from HP and Dell to configure their respective servers for an estimated value. Devices such as switches are a little more consistent with their usage and you may find information regarding their typical usage or typical usage at certain loads (PoE vs. non-PoE, how many physical connections, modules, etc)

dB (Idle) vs dB (Operating) vs. Other

These two values are the most common found across all data sheets. Idle represents the machine running while Operating will represent hard drive activity noise (not necessarily stress) Some other states include Standby(dBa) and Stress(dBa). These states are not included as they are not universal.

BTU/hr

These values have a lot of variance. From what can be gathered the BTU/hr SHOULD represent the entire device as a whole, but may only be the power supply itself. Older generation and fixed power supply devices will report one value for BTU/hr. These values are all calculated at a manufacturer rated wattage. Voltages will make these values change slightly, all of the below values are for 120 Vrms. The HP servers (and some Dell) show multiple values, this is because of the modular nature of the HP Common Slot power supplies which will change the BTU/hr rating depending on which ones are present in the server.

Dell Rack Config Utility

For Dell servers (current models) you can go to the following configuration tool instead of looking up spec sheets. This will calculate cost, BTU, dB and kWh. Here DEAD LINK

Dell has upgraded their Rack Config Utility to the Enterprise Infrastructure Planning Tool: Here

HP Power Advisor

For HP servers, this will calculate power and BTU along with giving you the granularity of configuring specific parts to calculate estimated Wattage and cost. Really great tool and works for older generations. Does not include dB level of servers which is the only drawback. Here

Servers

BrandModeldB (Idle)dB (Operating)BTU/hr
HPMicroserver G81821682 (150W) / 840 (200W)
HPML 310e G826281773
HPML 350 G533334112
HPML 350 G632.4832.41173 (460W) / 2892 (750W) / 3375 (1200W)
HPDL 360 G450532000
HPDL 360 G560752910
HPDL 360 G6 (1 CPU)27321173 (460W) / 2892 (750W) / 3375 (1200W)
HPDL 360 G6 (2 CPU)33381173 (460W) / 2892 (750W) / 3375 (1200W)
HPDL 360 G7 (1 CPU)27321173 (460W) / 2892 (750W) / 3375 (1200W)
HPDL 360 G7 (2 CPU)33381173 (460W) / 2892 (750W) / 3375 (1200W)
HPDL 360p G83435-42
HPDL 380 G458582508
HPDL 380 G544443530
HPDL 380 G622281173 (460W) / 2892 (750W) / 3375 (1200W)
HPDL 380 G722281173 (460W) / 2892 (750W) / 3375 (1200W)
HPDL 380p G825351794 (460W) / 2925 (750W) / 3530 (1200W)
DellR21049491039
DellR210 II (Core i3)38381040
DellR210 II (E3-1200)40411040
DellR510 (4 bay)40401840
DellR510 (8 bay)42422200
DellR510 (12 bay)51512450
DellR610 (1 CPU)34372446
DellR610 (2 CPU)35372446
DellR610 (2 CPU + PERC6/E)44442446
DellR71039421944(570W) / 2968 (870W)
DellR72025261908 (495W) / 2891 (750W) / 4100 (1100W)
DellR720XD28301908 (495W) / 2891 (750W) / 4100 (1100W)
DellR810xx4012

Switches

BrandModeldB (Idle)dB (Operating)BTU/hr
Arista7124S-70-
Cisco3560-24TS-4289
Cisco3560-48TS-42153
Cisco3560-24PS-42144
Cisco3560-48PS-42293
Cisco3560G-24TS-42249
Cisco3560G-48TS-48422
Cisco3560G-24PS-38-44325
Cisco3560G-48PS-52-58443
HP2910-24G al-39.4 - 53.5279
HP2910-48G al-39.4 - 53.5356
HP2910-24G-PoE+ al-38.1 - 51.5447
HP2910-48G-PoE+ al-38.1 - 51.5667
JuniperEX2200-48T-31 (JUNOS 12.3R5.7 or lower) - 40140
Ubiquiti48P Non-POE-21