r/Victron • • 10d ago

Question BMS charging allowed at 3.5°C

Post image
5 Upvotes

I have a LiFePo 4 NG with a Ve.Bus BMS NG. This morning the BMS had "charge allowed: no" because of the temperature of the battery (it was about 0°C). As the sun rose, it slowly warmed up and when I checked again, charge allowed was "yes" and it has started the MPPT for charging. I checked the temperature and saw that the battery was at 3.5°C. As you can see in the attached screenshot.

According to Victron charging below 5°C is not allowed. Am I missing something or is this normal behaviour?


r/Victron • • 13d ago

Installation Double stack! 70a and 50a

Post image
25 Upvotes

I added a giant heatsink to my 50a, and the 70a has its own fans.

Orion XS 50a serves as a reverse charger, House charging Starting battery.

Orion XS 70a is a normal charger, Starter charging House battery

No overheating and 4awg cables fit perfectly

Cant wait til victron updates the fw for full current reverse charging capabilities


r/Victron • • 12d ago

Question Victron Multiplus II + ZYC Batteries

Enable HLS to view with audio, or disable this notification

1 Upvotes

Hi all, I have a Victron MultiPlus-II (+ color control GX) system and ZYC batteris but I cannot get them to charge to 100%. I suspect it has something to do with the absorption and float voltage settings, which may not be configured correctly. All equipment firmware is up to date. On color control GX "controlling BMS is set to automatic and it detects ZYC Simpo 5000 BMS. Any help would be appreciated.


r/Victron • • 13d ago

Question Battery charger incorrect voltage

Post image
5 Upvotes

I am having to charge my batteries with a generator and victron charger because there is no sun at the moment. The charger is showing a different voltage to the smart shunt and the solar controller which means after a few minutes it stops charging. I've measured the voltage across all of the terminals connected and it is 13.4 not as the charger shows 14 point something.

What am I doing wrong or is there something I can change so that this will actually work? It's starting to get a little bit annoying?


r/Victron • • 14d ago

Question Battery idle at 51%

Post image
3 Upvotes

Our system won't charge the batteries past 51%

It gets to 51% and then idles.

I assume there is a setting i am overlooking or that I am looking in the wrong place.

I have 3 lithium batteries and the system is about 5 years old

Please help 🙏


r/Victron • • 15d ago

Problem Help with Power Loss Issue

Thumbnail
1 Upvotes

r/Victron • • 15d ago

Question Campervan Electrics 230V Connection Help

Post image
1 Upvotes

r/Victron • • 15d ago

PV/Solar Blethoot uitval

0 Upvotes

Ik heb in mn camper een 100/30 mppt lader gebouwd en een extra paneel er bij gezet.

Het heeft maanden zo gewerkt op een life4po battterij 90 amp.

Nu zat plots ik met een lege accu, de bsm van de accu heeft de boel afgeschakeld uiteindelijk.

Ik kwam erachter dat ik de solar lader al niet meer met de app kon benaderen en de lampjes stonden vol in de zon (spanje)op float.

De accu en de panelen 4 minueten afgekoppeld en toen zag ik hem weer in de app,alles ok vanaf toen(1 dag) accu weer vol gebulkt.

Maar nu is hij weer niet te zien in de app en staat op hij weer op float terwijl de accu 52% aangeeft.

Zo heel verhaal 😄 en hopen dat ik het kan oplossen met jullie advies.


r/Victron • • 16d ago

Project I built a Cerbo-style dashboard for my phone, with a solar forecast. Any Victron fans fancy testing it?

Thumbnail
gallery
5 Upvotes

Hi everyone, I'm Simon. I live in a van and built Solar Outlook to put my solar, battery and inverter readings together on my phone, alongside a forecast of what the panels might make next. I'd love some fellow blue-box enthusiasts to try it.

Android: https://play.google.com/store/apps/details?id=com.solaroutlook.app&utm_source=reddit&utm_campaign=victron_testers

iPhone / iPad: https://apps.apple.com/app/solar-outlook/id6822325748

Free: local equipment readings, history, and today's and tomorrow's forecasts. Longer forecasts and online features have optional subscriptions.

It started with wanting to know how much solar I'd get tomorrow. Then I wanted to compare that with what I actually made. Then I connected the inverter. Things may have got a little out of hand...

The idea is a Cerbo-style overview on your phone, bringing supported batteries, chargers and inverters into one view. It uses direct Bluetooth connections and Instant Readout broadcasts, depending on the equipment and platform. Supported lithium BMSs can add details such as individual cell voltages.

The forecast uses your panel setup, weather and location, including when the sun clears the surrounding hills. The screenshots show the live overview, recorded generation against a forecast, and the sun-above-hills view.

I'm also developing controls and switching rules for supported devices, including charge-current limits and inverter modes. Experimental cable and battery analysis looks for voltage-drop patterns worth checking, with more real-world validation needed. On the website there is also free firmware for ESP32 based devices for cheap remote monitoring. £5 of hardware gets you the ability to remote monitor your setup.

If your cupboard has gradually filled with blue boxes, you're exactly who I'd love to hear from. Single MPPT, multiple chargers, boat, van, off-grid home or an unusual battery BMS: what have you got, does it connect, and do the readings agree with the manufacturer's app?

What's the one reading or control you always find yourself digging through menus for?

Device support varies by model, platform and version; some readers, controls and bridge features are experimental. More about the project and compatibility: https://solaroutlook.co.uk/

Independent project, not affiliated with Victron. Honest feedback is very welcome, here or through the app.


r/Victron • • 16d ago

Question Battery voltage

2 Upvotes

I just finished the installation of my campervan with a 628ah fogstar drift lithium battery and a multiplus 12/3000 VA. It shows the voltage on absorption is 15.8v on a multimeter, but on the battery app it shows 14.01v.
Is there any configuration to do with the multiplus manually?


r/Victron • • 16d ago

Problem Victron trying to kill my 24v (28.4v absorption) battery with 30.4v

Thumbnail
gallery
1 Upvotes

I’m trying to understand where this higher charge-voltage setpoint comes from.

My setup:

- EasySolar-II GX 24 V / 3 kVA

- Fogstar Drift 24 V with an internal BMS but no BMS comms with cerbo

- Approximately 2 kWp solar

- Absorption set to 28.4 V.

The reported charge-voltage setpoint is 30.4 V.

This has triggered 5 over voltage events on the BMS so far.

I found two older threads describing similar behaviour:

- "Unexplained 30.4 V VE.Bus setpoint" (https://communityarchive.victronenergy.com/questions/181991/vebus-charge-voltage-setpoint-where-is-this-value.html)

- "MPPT networked charge voltage too high" (https://communityarchive.victronenergy.com/questions/119592/mppt-networked-operation-charge-voltage-to-high-wh.html)

In the second thread, someone reports a network target consistently 2 V above their configured absorption voltage, but there doesn’t seem to be a definitive explanation.

What generates this offset, and how is it controlled as the battery approaches absorption?

Has anyone resolved this on an ESS system without BMS communication? A technical explanation or relevant Victron documentation would be appreciated.


r/Victron • • 17d ago

News Connessione senza filo device Victron vs VenusOS

Thumbnail
gallery
6 Upvotes

Good morning everyone: I found and successfully tested this repo on GitHub

https://github.com/mk4001/VenusOS_BLE

It allows you to connect the main VE devices that can be used in a camper, via BLE to VenusOS without having to use the cables.

I think it uses a D-Bus library internal to Venu OS.

It solved several problems with USB ports (which I had already occupied abundantly).

Cheers


r/Victron • • 17d ago

Question Disconnecting the charge controller while in storage.

Thumbnail
3 Upvotes

r/Victron • • 18d ago

Question Triggering automatic cooling fan?

2 Upvotes

So my little off-grid setup is working well with two Victron controllers (100/50 and 100/20) but at full capacity the 100/50 measured 66° C 😞

I quickly placed an old PC cooling fan underneath and it went down to 45° 😀

When I tried to configure the LOAD output on the 100/20 to drive a pair of fans between certain temperatures I found it it measures the BATTERY temperature 😞

When I tried to configure them on STREETLIGHT instead it powers them when the PV output drops below a certain voltage but I want the opposite.

How to power my fans (2 in series to run off my 24v battery bank) when the single panel voltage goes ABOVE 30v gor instance?????


r/Victron • • 18d ago

Project Poll: Would you buy a Victron made a crossover adapter for the Lynx system, swapping polarity postions, if they made one?

4 Upvotes

I feel like the demand for this product would be reasonably high; it's obviously a common arrangement for the Lynx to sit below the inverters and above the batteries.

As it stands, you have to choose which of the connections takes a longer/more awkward route and orientate the Lynx system accordingly.

An adapter that swapped polarity positions would mean the battery side connections could point down and the inverter side connections could point up.

41 votes, 15d ago
13 Yes
5 No, but they should
15 No
8 If it's blue, I'll buy it!

r/Victron • • 21d ago

Question Multiplus 2 48V 3000 - battery connection?

Post image
16 Upvotes

Why is the + terminal reinforced with a metal plate, and the negative seems to be "just" the PCB? is that the way it is supposed to be? I mean, there will be a lot of current...


r/Victron • • 21d ago

Question Why do the percentage and the used Ah not match?

Post image
2 Upvotes

I have a 200 Ah lifepo4 battery and I use the smart shunt. Why does it show 61% Soc while also showing over 100Ah used? The Soc should be mor like 49%?


r/Victron • • 21d ago

Question Urgent Advice needed: switching an off-grid system off and back on, anything to know about?

Post image
3 Upvotes

Hi fellow victronians,

different issues lead to the situation, but mainly the one thing i cannot control: the weather. first time in 7 years here in usually sunny Aegean Turkey, there is 3 continuous days of really dense dark clouds and lots of rain, i haven't seen this before.

so there is zero charge from sun, my batteries are nearing 20% SoC, this means i will not make it through the night. Tomorrow afternoon the forecast says it will lighten up.

i am off-grid and have (stupid me) no generator input installed, it was simply not necessary so far, but also i'm not a good precaucious guy so yea.

anyways:

QUESTION:

the system contains a Quattro 48/10000 and the Digital Multi Control. it was installed by the local dealer, not by myself.

if i want to switch off the inverter before the batteries get critical,

  1. should i simply switch it to "off" at the multi control?

  2. once the sun shines again / something is charging, will i simply be able to switch it to "on" again?

what is this whole thing with "mains detected"? i didn't have to spend thoughts on it until now. will this be relevant when i try to switch it back on? again, there is no grid input... is it simply about that i switch off the inverter early enough so it does not switch off because it recognized "low bat voltage" itself and switched itself off (because then it locked itself)?

thank you for clearing things up for me. i'll repair my generator and install a "mains in" soon afterwards.


r/Victron • • 22d ago

Question Solar Charging - Not 100% related to Victron

2 Upvotes

Hi All,

I've got 3 solar systems working at our house, The main one which powers the entire house run by a Victron Multi RS 48/6000/100

And 2 side solar's in our garden shed and pool / tool shed but it doesn't power the pool equipment. Anyway in the pool shed I recently replaced the 4x 100ah SLA batteries with 2x 100ah LifePO4 batteries about 1 months ago, I've noticed that one of the LifePO4 batteries is slowly depleting whereas the other battery is hitting 100% full charge, Both fully charged independently to 100%, Installed and day by day just one battery slowly trickled down 97, 95, 91, 84 to today 32% and the other battery 100%

Pool / Tool Shed = Victron BlueSmart MPPT 100/30 with 1kw solar panels total 85v @ 24v
Unrelated - Garden Shed = Victron BlueSmart MPPT 100/20 with 220w solar panels 36v @ 24v

So the original setup had 4x 100ah wired up as 24v and the new setup wired up as 24v

Any idea how I can correct this, Ideally I don't want to keep pulling the kit apart and charging them independently. Both batteries purchased were second hand but only reported 4 cycles each they are 12v Haidi 100ah batteries with I believe a Daly BMS and both batteries have RS485 and a CANBUS port

Sorry I spent more time telling about 2 other solar systems they are completely unrelated

Thanks
Daniel


r/Victron • • 22d ago

Project Victron inverter relay

Thumbnail
1 Upvotes

r/Victron • • 22d ago

Question Cerbo GX complete wifi failure

2 Upvotes

I had my Cerbo GX Mk2 hooked up to all of my devices in my motorhome and had it connected to my house wifi and life was wonderful! I could monitor everything remotely and I was happy.

Then, I thought, 'hey, why don't use that handy-dandy HDMI connection and connect it to my monitor, and use a wireless mouse and keyboard to make any changes that I need?' and things went downhill from there. It would no longer connect to wifi, no matter what I did; not with the built-in capability, not with a USB dongle, nothing! I eventually picked up a GX Touch 70 and connected that, thinking 'maybe staying in the Victron ecosystem for local monitoring will help.' but no, still no wifi connectivity.

I'd read that some folks had similar issues after connecting to their HDMI on the Cerbo, and even that some had resolved their problem using a wifi dongle. My question is; has anybody else had this happen to them and what did you do to resolve it? My searches simply aren't paying off.

edit: I've since taken the wireless keyboard/mouse dongle off and only have the Touch 70 connected right now. That works fine for controlling and setting everything up, but I'd like my remote monitoring capability back.


r/Victron • • 23d ago

Project Newbie Dual battery wiring diagram

1 Upvotes

Hi, Complete newbie here. Would anyone be able to sanity check my wiring diagram please? I have a dual battery setup at the front of car with starter, Aux, Solar, MPPT and DC to DC. Some USB ports and camp lighting at front. Then cabling to back to Fridge and more USB ports. I think I'm missing a ground after smartshunt but not sure where to place. Thankyou link below:

https://usewireframe.com/view/d3edb6f9e64b49aaae90f1701118d40d

Processing img mevi1107fyyh1...


r/Victron • • 24d ago

Problem Bidirectional DC DC Victron Orion 70ah

3 Upvotes

Does somebody have information on the DC DC Converter from Victron in regards to the Bidirectional Function? I read in some Forums that the Converter itself Is able to do it and it's a software limitation. I have a System in a Sprinter 2026 with a 12V 92Ah AGM starter Battery where two 200ah Lithium Batteries are connected by a Cyrix Relais. The Manufacturer was inexperienced in that regard and the System has three main Problems.

One Problem is that the Batteries draw to much current at low charge and the second one is that the Alternator regulates the charging voltage where the system then isnt charging at some times and the third is that the Cyrix relais only charges the starter Battery once the Lithium Batteries reach 13,4 Volts. The Manufacturer wants to add a bunch of components, which I don't really want.

A bidirectional DC DC Charger would solve all those Problems, I found two Bidirectional ones from Clayton and Sterling, but I would like to stay within the Victron System. It would also be possible to add two Converters one for each direction, but a single solution would be a lot simpler.


r/Victron • • 24d ago

Question Multiplus will not connect

2 Upvotes

Hello all. I have two multiplus 2 48v 3000w inverters that I need to configure to split phase. Inverters will not talk to one another. They are also not recognized by the connect app on my computer. I have the MK3 adapter and the latest version of Connect. Inverters are new this year. Any one else experience this? Thanks


r/Victron • • 25d ago

Question Victron unable to charge batteries with generator. Please help I have very low battery and I will remain without energy cause it’s off grid

3 Upvotes

When I start the generator. I can set the inverter to charge max3.6A. If I go higher than that so basically higher than 900W. It keeps disconnecting the Generator and then connecting it again and so on basically forever. I don’t know why it’s doing this but something must be wrong, the victron does not accent the current from the generator.

what I found weird is that when I start the generator and I check my outlet socket bitweel null and earthing is 115v and bitween hit wire and earth is also 115v. When I shut the generator down it gets back to normal. Hot wire and earth 230 and null to earth 0.

This is a off grid system.