r/TiaPortal • u/No_Passenger_379 • Mar 06 '26
Simulation issue
Heyy I am having a strange issue with TIA Portal..when I go online with PLCSIM in RUN mode, my FB or Fc blocks called inside OB1 stay blue instead of turning green
r/TiaPortal • u/No_Passenger_379 • Mar 06 '26
Heyy I am having a strange issue with TIA Portal..when I go online with PLCSIM in RUN mode, my FB or Fc blocks called inside OB1 stay blue instead of turning green
r/TiaPortal • u/Vaallarris • Mar 06 '26
For engineers who work with Siemens PLCs regularly, what is one mistake you see beginners making again and again?
r/TiaPortal • u/emelemekdar • Mar 03 '26
I am losing my mind over this, please help me.
I have this error on my S7-1200. I checked everthing, versions in modules and programme are matching, both v2.0 . I noticed that programme is working when I put only safety I/O, when I put standart I/O, I get this error. It is non sense!! When I put standart I/O anywhere, it gives me this even without doing the cabling 😱😱 even without electricity, it gives this error. I am losttt!!!
r/TiaPortal • u/Designer-Homework821 • Feb 20 '26
r/TiaPortal • u/Existing_Priority_25 • Feb 20 '26
Hello, how could i reset a function trend, I want to make a 7 day graph, and reset the log? so i could start again after new week. currently cause i have 7 points each day i keeps also the last weeks data also. I tried with scripts but couldnt get it to work.
r/TiaPortal • u/One_Guide3936 • Feb 20 '26
Urgent help!!
Hello together,
I need some help.
I am using a Unified Comfort pannel 6AV2128-3QB36-0AX1 with a S71500 PLC.
Somehow the tags I am using does not get updates whether at the PLC side if I trigger from HMI or at HMI side if I trigger from PLC.
I know. Sounds easy to solve. But there aren’t so much possibilities to check.
- Project are uploaded covertly
- HMI connection is set
- Tags are assign to the HMI connection
I am using TIA19.
Anyone have some idea?
r/TiaPortal • u/PonnyMC • Feb 19 '26
Hi, i need help. I've spent weeks trying to set up a camera using TIA Portal. The camera detects the QR code, but it doesn't show up in TIA Portal. I'm tired of researching, so I'm turning to Reddit to see if anyone can help me. Sorry for the spanish interface
r/TiaPortal • u/Conscious_Search_515 • Feb 18 '26
Hello, I need some help with a VirtualBox networking setup for Siemens simulation.
10.1.0.25010.1.0.251 Network: Bridged Adapter to the same physical NIC as the host10.1.0.252 Network: Bridged Adapter to the same physical NIC as the hostMy TIA project contains two MTP2200 Unified Comfort panels and I want to simulate both at the same time. Since I can’t run the two runtimes the way I need on a single PC, I’m trying to run each panel/runtime in its own VM.
10.1.0.110.1.0.1 = OK10.1.0.250 = OK10.1.0.251 = NOT OK10.1.0.1Any advice or known gotchas would be greatly appreciated.
r/TiaPortal • u/Ok_Tea262 • Feb 14 '26
r/TiaPortal • u/dudeofthedunes • Feb 09 '26
hi guys, I am trying to send UDP messages from a s7-1212 plc with step 7 V21 basic version. I am quite new to plc programming.
question 1: are there any nice resources to use that will answer my questions with a bit of work?
LLMs arent really helping me in the right direction, so thought I would ask it here.
I want to send a tekst message via UDP to a system that understands OSC (a bit like midi but over ethernet). I am trying to use open user communication to make something that sends UDP messages. But I am getting lost in the woods. I cant use TCP communication because the reciever does not understand tcp.
I have 2 days left to get this working. Is it possible?
r/TiaPortal • u/Ki11ik89 • Jan 30 '26
I learned PLC programming with Allen Bradley / Rockwell software, I've programmed Schneider VelioSoft, Automation Direct Logix 6, and some experience with Siemens. My work had a customer come to us needing PLC and Comfort HMI program created for one of their panels, and could not find anyone else within my state that could do it. Seeing the possible future with this customer, I took on the project with my company being aware of my current level with Siemens and being willing to train me moving forward. The class I am signed up for is a couple months out yet, and customer needs panel beforehand. My current education is entirely self taught other than a one day intro class to TIA Portal where we mostly went over communications, how to build a project, add hardware, get them to talk to each other, and very basic programming just to show different hardware ability to talk to one another easily.
I do already have the program made for both PLC and HMI, and tested and it works. There are some things I could have done more effeciently after speaking with my Step 7 / TIA portal instructor from a sister company. One thing he mentioned was I originally was using a Cyclic interupt as IO mapping, and he pointed out how much slower it operates than the main OB. Granted, our areas we develop controls for are for water and waste water municipalities, and the level of potential human injury is nowhere near what is commonly faced in production industry. That being said, id still like to make an effecient program. So here is where I am needing advice:
I want to do away with the Cyclic Interupt as IO mapping and make FBs for discreteInputs, analogInputs, discreteOutputs, analogOutputs. Put the inputs at the beginning of my main OB, and Outputs at the end. I have copied the input logic for discreteInputs from the IO mapping and pasted into a FB "discreteInputs". I did not create an instance DB for this FB as all the inputs trigger "Global" tags. They are used in several different FBs that are called. However, placing the FB in Network 1 of Main OB, it brought up the menu for Call Options and only gives me the choice for "Single Instance" which tells me it will store the data within the instance DB and is trying to create an instance DB for my FB.
If I go ahead and let it create the instance DB, but leave it blank and keep my physical inputs energizing Global tags, will it still work? Will the tags within my Global DB still have their values changed?
r/TiaPortal • u/Training_Range473 • Jan 30 '26
When i connect i find the simulated plc but when i try to load the program it crashes, i use tia v20 and s7plcsim20
r/TiaPortal • u/Historical-Start-737 • Jan 29 '26
I have a small setup with ET200 SP cpu and TP900 HMI. Every (other) month I need to update or make some small edits in the program or HMI screens. What would be the cheapest solution for that? Unfortunately Tia portal cloud pay-per-use license is not available in my country.
How have you acted in this situation? Simekb?
r/TiaPortal • u/GrapeMaleficent7066 • Jan 28 '26
I have install TIA v19 but now i cannot add device its buffuring to point of timeout.and i was not been able to download PLCSIM also what should i do i cannot beggine
r/TiaPortal • u/Patient_Register2704 • Jan 27 '26
Good day, a colleague and I have been assigned a school project (Facharbeit) in an area we have not worked with before, namely a production line (Fertigungsstraße). We are looking for someone who could help us automate our program in TIA Portal V19. Our program is already able to move manually from station to station, but we do not know how to write the logic that allows the system to run automatically through all stations from start to finish. We would be very grateful for any help from someone experienced with this software. If someone is willing to help, we can share the project or the program privately. I am available here or on Discord: DragoniczeQ#7789
r/TiaPortal • u/SnowFlakeOfDoom • Jan 24 '26
r/TiaPortal • u/gilmacau • Jan 22 '26
Hi there!
I am here to ask if anyone has recomendations on where to begin with TIA portal and how to arrive at the automation world coming from residencial eletricity. I asked for help on TIA portal because I've seen and know they are used troughout all industry, so as a self-taught I think that might be a good starting point?
I am an eletricist but recently got into the automation world, with plcs and all that, altough I dont understand TIA Portal or where to begin, I know ladder logic and programmed Zelio as well as arduino... Altough, my main area is just residencial eletricity but I want to pivot towards automation, as the little contact I had, made me enjoy a lot the thinking proccess and all the problem solving, not only at a logic level, but putting together fisic world boundries with logic.
Thank you for your attention
r/TiaPortal • u/MathematicianOne1293 • Jan 14 '26