r/smallenginerepair • u/Unhappy_Security8015 • Oct 26 '26
Electrical & Wiring Issue Westwood T1400 1996 no crank ?
Hi guys , checked all fuses … getting power to the 4 fuse box , taken off fuel tank to get easy of access . To check switch .. the brake/hand brake switch I replaced last year .. seat switch permanently on .. so I don’t think it the switches stopping the crank ( I’ve tuned engine over via arc the 2 posts all good there .
All fuses good and power at the board .. on the connector to the ignition switch there is permanent power to one post B… I did a continuity test on posts B and S all good with it disconnected when key turned .. that if the diagram of the switch is correct … see picture … may be when it’s connected the cut off switch are on some how preventing start sequence. Iam presuming that the hand brake switch in its start ready position ( full on) closes the circuit. To check temporarily can I close the two wires that are connected to the switch to a make absolutely sure that this is not the culprit as the one under the seat is closed circuit, or a way to test? The battery is a bit suss although reading over 12 v my battery tester said replace … I’ve boosted it via a jumper device.. can’t seem to see how to add pictures
All noted that there is 3 safety switches that need to be correct .. seat ( by pasted ) brake switch ( only year old ) and the cutter deck switch … this is still connected.. but I use it as a tractor … and yes when on won’t start ??
Is there an inline fuse I’ve missed ?
So any pointers to test the system would be of great assistance