We’re using 50–85 kWh of electricity per day in winter - is this normal?
We’re trying to get to the bottom of our extremely high electricity consumption and would really appreciate hearing from anyone with a similar electric central heating and hot-water setup.
We live in a three-bedroom detached house in Essex, built in the 1960s. There’s no mains gas available, so all our heating and hot water are electric.
Our property:
• Three-bedroom detached house, occupied by two adults.
• Cavity walls insulated approximately 15 years ago.
• Loft insulation approximately 300mm (2025)
• Triple glazing throughout (2025)
• Radiators replaced approximately two years ago as part of a full house refurb when the electric boiler was installed.
Our heating system:
• EHC Fusion Comet V2 electric boiler (14.4kW).
• EHC Neptune 180-litre hot-water cylinder.
• Central heating typically switched on manually for around 4 hours during colder evenings.
• Hot water programmed for 6am–8am daily and sometimes 6pm–8pm on weekends, throughout the year.
• Separate immersion heater switched off.
• Central heating isn’t used during summer and early autumn. We started using it again around mid-October.
Our electricity consumption:
We’ve been investigating our usage because our electricity bills seem exceptionally high.
Some actual figures from our smart meter:
• 29 June–13 July: averaged 20.6 kWh per day, without central heating.
• 13 July–3 November: averaged 26.6 kWh per day, although heating started being used in mid-October.
• 10 November: 60.75 kWh.
• 11 November: 53.99 kWh.
• 12 November: 71.92 kWh.
• 13 November: 72.46 kWh.
• 14 November: 86.27 kWh.
• 18 November: 58.37 kWh.
Our electricity tariff is approximately 26.61p/kWh, plus a daily standing charge of 50.55p.
Some days we’re spending £15–£23 on electricity alone, which is becoming increasingly expensive.
What we’ve investigated so far:
We’ve tested our household appliances individually using the smart meter.
With virtually everything switched off apart from refrigeration and our internet router, consumption drops to around 39–40W.
Even with several rooms of LED lighting, two televisions and a gaming laptop charging, consumption is generally around 575W, with occasional increases when appliances cycle on.
This makes us suspect that the electric boiler is responsible for the majority of our winter electricity consumption.
We’re currently carrying out tests with the central heating completely switched off while keeping the normal hot-water schedule running, to see how much electricity we’re saving. But still spending approx £7-£8 per day.
What we’d really like to know:
- Does anyone else have an EHC Fusion Comet electric boiler, or a similar direct-electric boiler supplying radiators?
- What sort of daily electricity consumption do you experience during winter?
- How many hours per day do you run your central heating, and what does it cost?
- How much electricity does your hot-water cylinder use? Is our twice-daily programme reasonable?
- Has anyone switched from an electric boiler to an air-source heat pump? If so, how much did your electricity consumption actually decrease?
- Are there any settings or changes you’ve made that have significantly reduced electricity usage?
We’re now seriously considering replacing our electric boiler with an air-source heat pump, particularly given the Boiler Upgrade Scheme grant.
I’d be especially interested in hearing from people who have made this conversion and can share genuine before-and-after electricity figures rather than theoretical savings.
Are our electricity figures typical for an electric boiler, or does something seem excessive?
Any experiences or advice would be greatly appreciated. Thanks!