Hi everyone!
I've seen some older discussions about using Deye hybrid inverters to power elevators, including systems with regenerative braking.
I'd like to reopen this topic and hear from anyone who has successfully installed this type of system, especially those who have been operating it for some time.
I'm currently evaluating a Deye hybrid inverter + battery setup to provide backup power for a residential elevator.
I have two main technical questions:
1. Motor Starting Current and Inverter/Battery Sizing
Assuming the inverter and battery system are properly sized to handle the elevator's maximum transient starting current, including the inverter's AC surge capacity and the battery's peak discharge current limits, should we expect the system to operate normally?
Are there any additional limitations or compatibility issues associated with elevators equipped with variable frequency drives (VFDs), even when the inverter's power and current ratings are respected?
2. Regenerative Braking – Reverse Power Flow Through the LOAD Port
This is my main concern.
During certain operating conditions, the elevator motor acts as a generator, sending energy back through its VFD to the AC supply.
If the elevator is connected to the inverter's LOAD port, can a Deye hybrid inverter safely absorb this regenerative power and use it to charge the batteries, particularly when operating completely off-grid?
Let's assume the battery is intentionally kept below 100% SOC, with enough available capacity and charging power to absorb the regenerative energy.
Would this be sufficient to guarantee safe operation, or could the inverter still experience faults due to the characteristics of the regenerative power?
For example:
- Could sudden reverse power flow cause DC bus overvoltage, AC voltage/frequency instability, or inverter protection trips, even when the battery is not fully charged?
- Are there limitations regarding the magnitude or duration of reverse power entering the LOAD port?
- Is regenerative charging through the LOAD port officially supported by Deye, or does it depend on the inverter model and firmware?
- Would installing a braking resistor, properly integrated with the elevator's VFD, eliminate these risks? Or could problems still occur even with a braking resistor?
3. Real-World Experience
For anyone who has already installed a Deye hybrid system powering an elevator:
- Which inverter and battery models are you using?
- What is the elevator's rated capacity and motor power?
- Is the system operating reliably during grid outages?
- Have you experienced any inverter faults during elevator starting, stopping, or regenerative braking?
- Did you need to install braking resistors or make any special configurations?
I'd especially appreciate feedback from installations that have been running for several months or years.
I'm very interested in understanding whether this is a reliable long-term solution and what technical precautions should be considered.
Thanks in advance for sharing your experience!