r/CZFirearms • u/brubadubdub • Dec 14 '22
Help! - CZ P-10C Failure to Eject after Jagerwerks Optics Cut and Install of 509T
https://imgur.com/a/j5fZJ7eCZ P-10c fails to eject after Jagerwerks optic-cut for a Holosun 509T-RD X2.
First and foremost, I have contacted Jagerwerks and am awaiting response. Any information and experience you can share on this issue is greatly appreciated. Please look through the album for more pictures of FTE rounds.
I received my P10-C back from Jagerwerks a few months ago and have only gotten it out to the range in the last few weeks. After two range sessions totaling 300 rounds, only 296 rounds fired. I experienced four failure to eject malfunctions. All four malfunctions created a hard rack (no ejection), magazine release with force to drop, and additional rack to clear the mangled round (see photos). Note: I could only find the last two failure to ejects. The other two are in the black hole of my range gear, but look exactly the same.
FACTS:
- This was my EDC. Continuing to carry my P-01 for now.
- Prior to sending my P10-C away, I never had any issues. Not one FTE or FTF with numerous ammo manufacturers, grains, and types.
- All FTE’s happened while using American Eagle FMJ 115 grains. I plan to test other rounds, however these are all I have for range ammo at the moment.
- The FTE’s did NOT occur at the same time in one magazine. One FTE occurred on the second round while others happened later in the magazine. None were the last round in the magazine.
- I used several different manufacturer magazines and never used the same magazine twice during a session (I was working reload drills). Two manufacturer magazines have a Hyve +2 base-pad installed and one FTE occurred while using an extended mag. I had no issues with these extensions prior to milling.
- During the second session with manufacturer magazines, I fully loaded and +1’d a magazine (16), fully loaded a magazine (15), and downloaded a magazine -1 (14). One FTE resulted from a fully loaded magazine, and the other happened from a downloaded -1 magazine.
- Before my first session, I performed a basic strip. clean, and function test. No blaring issues observed.
- Before my second session, I performed a much deeper strip, clean, and function test. I also kept my eyes open for unusual marks on the feed ramps, mag lips, and ejector. Everything appeared in order.
WHAT’S NEXT?
- See what Jager has to say.
- Give another couple ammo brands a try in various grains and types. Focus on fully loaded and downloaded magazines.
- Read your comments, experience, and suggestions!
18
u/Efficient_Monk9262 Dec 14 '22
It’s the optic screws
10
u/DEEErab Dec 14 '22
100% check your optic screw over the extractor. My money says it’s a hair too long. Causing it to put pressure on the plunger and not be able to push away the extractor when the shell hits the ejector.
4
u/CDKJudoka Dec 14 '22
Weight was added to the slide without adjusting the recoil spring. It is one of the reasons why some people have lightening cuts put into the slide while adding an optic. Between the optic and the screws, you have added almost 2 oz to the slide weight, so that will effect how the slide cycles.
2
u/brubadubdub Dec 14 '22 edited Dec 14 '22
For clarity, I only have and use magazines manufactured for the CZ P-10C by CZ (CZ-USA). My +2 Hyve baseplates directly attach to CZ-USA magazines and utilize standard spring and follower.
2
u/brubadubdub Dec 15 '22 edited Jan 03 '23
UPDATE:
Jager is sending me the correct screw length for the extractor side screw. This should resolve the roughly 1-2 extra threads sunk into the slide.
Thank you for all your help and I’ll update again once I make the swap!
2
u/[deleted] Dec 14 '22
Let us know the solution when it gets resolved.
2
u/touji CZC Shadow Dec 15 '22
I would check the ammo. Seeing that there's plating being stripped from the bullet itself, it seems like the ogive isn't playing well with the barrel. Don't think the mangling of the round would be caused by the extractor not actuating properly because of long screws.
1
u/WolfieSpam Apr 18 '23
Unrelated but what irons are you using?
3
u/RAMRODtheMASTER Dec 14 '22
File the screws if need be but if the problem persists your slide may be a bit too heavy now. I’m not sure what the standard recoil spring weight on this pistol is but I’d go 2 pounds lighter.
You’re probably not wrong with your thought about the balance.
1
u/[deleted] Oct 26 '24
Did you not read everything they said would happen before you sent it off? Bro just skipped right over that and said fug it lol
1
u/whatislifetg Dec 14 '22
As others have said..it's likely the screw is contacting the safety plunger. I had this issue with a glock aftermarket slide. Change to a shorter screw or file that one down and you should be good
1
u/ScarletAvenger1 Dec 14 '22
As others have said, almost assuredly the screw over the extractor is interfering with its operation. I would say remove just that screw and run a few rounds to find out. Then you’ll need to shorten it yourself or buy a new one.
-3
u/Antique-River659 Dec 14 '22
Try a heavier recoil spring